DLA MIL-DTL-83800 B-2009 PROPANEDIOL 1 2-.pdf
《DLA MIL-DTL-83800 B-2009 PROPANEDIOL 1 2-.pdf》由会员分享,可在线阅读,更多相关《DLA MIL-DTL-83800 B-2009 PROPANEDIOL 1 2-.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Comments, suggestions, or questions on this document should be addressed to Defense Supply Center Richmond, ATTN: DSCR-VEB, 8000 Jefferson Davis Highway, Richmond, VA 23297-5616, or e-mailed to STDZNMGTdla.mil. Since contact information can change, you may want to verify the currency of this address
2、 information using the ASSIST database at https:/assist.daps.dla.mil/. AMSC N/A FSC 6810 METRIC MIL-DTL-83800B 22 December 2009 SUPERSEDING MIL-P-83800A 1 July 1983 DETAIL SPECIFICATION PROPANEDIOL, 1,2- Reactivated after 22 December 2009 and may be used for new and existing designs and acquisitions
3、. This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers one type of 1,2-propanediol, hereinafter referred to as propylene glycol. 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are
4、 specified in sections 3 and 4 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned
5、 that they must meet all specified requirements of the documents cited in sections 3 and 4 of this specification, whether or not they are listed. 2.2 Non-government publications. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issu
6、es of these documents are those cited in the solicitation or contract. AMERICAN CHEMICAL SOCIETY - Reagent Chemicals (Copies of this document are available online at http:/www.acs.org/ or from American Chemical Society, 1155 Sixteenth Street NW, Washington, DC 20036.) Provided by IHSNot for ResaleNo
7、 reproduction or networking permitted without license from IHS-,-,-MIL-DTL-83800B 2 AMERICAN SOCIETY FOR QUALITY (ASQ) ASQ Z1.4 - Sampling Procedures and Tables for Inspection by Attributes (Copies of this document are available online at http:/www.asq.org/ or from American Society of Quality, 600 N
8、orth Plankinton Avenue, Milwaukee, WI 53203.) ASTM INTERNATIONAL ASTM D 92 - Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester ASTM D 891 - Standard Test Method for Specific Gravity, Apparent, of Liquid Industrial Chemicals ASTM D 1078 - Standard Test Method for Distillatio
9、n Range of Volatile Organic Liquids ASTM D 1193 - Standard Specification for Reagent Water ASTM D 1209 - Standard Test Method for Color of Clear Liquids (Platinum-Cobalt Scale) ASTM D 1613 - Standard Test Method for Acidity in Volatile Solvents and Chemical Intermediates Used in Paint, Varnish, Lacq
10、uer, and Related Products ASTM D 4057 - Standard Practice for Manual Sampling of Petroleum and Petroleum Products ASTM E 202 - Standard Test Methods for Analysis of Ethylene Glycols and Propylene Glycols ASTM E 203 - Standard Test Method for Water Using Volumetric Karl Fischer Titration (Copies of t
11、hese documents are available online at http:/www.astm.org/ or from ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959.) 2.3 Order of precedence. Unless otherwise noted herein or in the contract, in the event of a conflict between the text of this document and
12、the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Chemical and physical requirements. The chemical and physical requirements of the
13、propylene glycol shall be as specified in table I. 3.2 Workmanship. The propylene glycol shall be water white, a homogeneous liquid, free from dirt, sediment, and other suspended foreign matter when examined visually by transmitted light. Provided by IHSNot for ResaleNo reproduction or networking pe
14、rmitted without license from IHS-,-,-MIL-DTL-83800B 3 3.3 Recycled, recovered, or environmentally preferable materials. Recycled, recovered, or environmentally preferable materials should be used to the maximum extent possible, provided that the material meets or exceeds the operational and maintena
15、nce requirements, and promotes economically advantageous life cycle costs. TABLE I. Chemical and physical requirements. Limits Requirements Min. Max. Test Color (Pt-Co scale) - 10 4.4.1 Specific gravity at 20 C/20 C 1.0375 1.0390 4.4.2 Distillation, C Initial boiling point Dry point 185 - - 189 4.4.
16、3 Acidity (as acetic acid (% by wt) - 0.003 4.4.4 Moisture (% by wt) - 0.20 4.4.5 Ash (% by wt) - 0.005 4.4.6 Iron (ppm) - 0.5 4.4.7 Chlorides (ppm) - 1.0 4.4.8 Flash point, C 107 - 4.4.9 4. VERIFICATION 4.1 Classification of inspection. The inspection requirement specified herein is classified as c
17、onformance inspection. 4.1.1 Conformance inspection. The material shall be subjected to all the following inspections and tests for acceptance. When specified in the contract (see 6.2), the supplier shall submit a report giving the results obtained for all inspections and tests performed and certifi
18、ed statement that the lot meets all the requirements of this specification. Where applicable, blank determinations shall be run and corrections applied where significant. Safety apparel will be worn at all times. 4.1.1.1 Purity of reagents. Reagent grade chemicals shall be used in all tests. Unless
19、otherwise indicated, all reagents shall conform to the specifications of the Committee on Analytical Reagents of the American Chemical Society, where such specifications are available. Other grades may be used, provided it is first ascertained that the reagent is of sufficiently high purity to permi
20、t its use without lessening the accuracy of the determination. 4.1.1.2 Purity of water. Unless otherwise indicated, references to water shall be understood to mean reagent water conforming to type II or III of ASTM D 1193. 4.1.2 Visual inspection. All samples shall be visually inspected to determine
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILDTL83800B2009PROPANEDIOL12PDF
