DLA MIL-DTL-7601 C-2011 GAGE EMERGENCY OXYGEN TYPE L-2.pdf
《DLA MIL-DTL-7601 C-2011 GAGE EMERGENCY OXYGEN TYPE L-2.pdf》由会员分享,可在线阅读,更多相关《DLA MIL-DTL-7601 C-2011 GAGE EMERGENCY OXYGEN TYPE L-2.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、Comments, suggestions, or questions on this document should be addressed to DLA Aviation VEB, 8000 Jefferson Davis Highway, Richmond, VA 23297-5616, or e-mailed to STDZNMGTdla.mil. Since contact information can change, you may want to verify the currency of this address information using the ASSIST
2、database at https:/assist.daps.dla.mil/. AMSC N/A FSC 6685 INCH-POUND MIL-DTL-7601C 17 October 2011 SUPERSEDING MIL-G-7601B 15 November 1982 DETAIL SPECIFICATION GAGE, EMERGENCY OXYGEN, TYPE L-2 Reactivated after 17 October 2011 and may be used for new and existing designs and acquisitions. This spe
3、cification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers one type of high-pressure, emergency oxygen gage, range 0 to 2,500 pounds-force per square inch gauge (psig), designated type L-2. 2. APPLICABLE DOCUMENTS 2.1 Ge
4、neral. The documents listed in this section are specified in sections 3 and 4 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the complete
5、ness of this list, document users are cautioned that they must meet all specified requirements of the documents cited in sections 3 and 4 of this specification, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications and standards. The following specifications and standards fo
6、rm a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-7601C 2 FEDERAL STANDARD FED
7、-STD-595/31136 - Red, Flat or Lusterless COMMERCIAL ITEM DESCRIPTION A-A-59503 - Nitrogen, Technical DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-PRF-27210 - Oxygen, Aviators Breathing, Liquid and Gas DEPARTMENT OF DEFENSE STANDARDS MIL-STD-130 - Identification Marking of U.S. Military Property MIL-STD-
8、889 - Dissimilar Metals MIL-STD-31000 - Technical Data Packages (Copies of these documents are available online at https:/assist.daps.dla.mil/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.3 Non-government publications. The followin
9、g documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. ASTM INTERNATIONAL ASTM B545 - Standard Specification for Electrodeposited Coatings of Tin (Copies of this document are
10、available online at http:/www.astm.org/ or from ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959.) SAE INTERNATIONAL SAE AS71051 - Pipe Threads, Taper, Aeronautical National Form, Symbol ANPT - Design and Inspection Standard SAE AS8879 - Screw Threads - UNJ
11、Profile, Inch Controlled Radius Root with Increased Minor Diameter SAE AS5201 - Fitting End, External Taper Pipe Thread, Design Standard (Copies of these documents are available online at http:/www.sae.org or from SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001.) Provided by IHS
12、Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-7601C 3 2.4 Order of precedence. Unless otherwise noted herein or in the contract, in the event of a conflict between the text of this document and the references cited herein, the text of this document takes
13、precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 First article inspection. When specified (see 6.2), sample gages shall be subjected to first article inspection in accordance with 4.3. 3.2 Mat
14、erials. 3.2.1 Nonferrous materials. Unless otherwise specified, nonferrous materials shall be used for all parts of the gage except where ferrous materials are essential. Ferrous materials, when used, shall not come in direct contact with oxygen. 3.2.1.1 Dissimilar materials. Unless suitably protect
15、ed against electrolytic corrosion, dissimilar metals shall not be used in intimate contact with each other. Dissimilar metals are defined in MIL-STD-889. 3.2.2 Nonmetallic materials. Any nonmetallic material that is easily deteriorated or otherwise easily affected adversely by continued service use
16、with oxygen shall not be used. 3.2.3 Protective treatment. When materials are used in the construction of the gage that are subject to corrosion in oxygen, salt air, or other atmospheric conditions likely to occur during service usage, they shall be protected against such corrosion in a manner that
17、will in no way prevent compliance with the performance requirements of this specification. The use of any protective coatings and finishes that will crack, chip, or scale with normal service life, age, or extremes of atmospheric conditions shall not be used. 3.2.4 Recycled, recovered, or environment
18、ally preferable materials. Recycled, recovered, or environmentally preferable materials should be used to the maximum extent possible, provided that the material meets or exceeds the operational and maintenance requirements, and promotes economically advantageous life cycle costs. 3.3 Design. The ga
19、ge shall be designed to conform to figure 1. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-7601C 4 NOTES: 1. All dimensions are shown in inches. 2. Unless otherwise specified, all tolerances shall be 0.016. 3. Dial text and numerical markin
20、gs shall be not less than 0.062 in height. 4. 1/8ANPT fitting shall be tinned in accordance with ASTM B545. 5. The left-most end of the dial range (below 1800), the “REFILL“, and the “USE NO OIL“ markings shall be colored a flat, lusterless red to conform with FED-STD-595/31136. 6. All other dial ma
21、rkings and the pointer shall be colored flat black. 7. The left edge of the pointer shall be considered the indicating edge. 8. The dial face shall have a white background. FIGURE 1. Gage, emergency oxygen, type L-2. 3.4 Construction. The gage shall be so constructed that no parts will work loose in
22、 service. The mechanism shall be built to withstand without failure, the strains, jars, vibration, and other conditions incident to shipping, storage, installation, and service. Pivots, bearings, and gears, shall neither bind nor shake, and shall be as near frictionless as practicable. The gages sha
23、ll be so constructed that minor repairs such as replacement of cover glasses and pointers can be easily made by the personnel of the operating units without the use of special tools. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-7601C 5 3.4
24、.1 Hair springs. If hair springs are used in the construction of the gage, they shall be made of beryllium copper or phosphor bronze. 3.4.2 Bourdon tube. The bourdon tube shall be constructed of beryllium copper. 3.4.3 Viewing window. The viewing window shall be constructed of transparent plastic ma
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILDTL7601C2011GAGEEMERGENCYOXYGENTYPEL2PDF

链接地址:http://www.mydoc123.com/p-691071.html