1、 MIL-DTL-49285/28A 1 March 2010SUPERSEDING MIL-C-49285/28 19 October 1989 DETAIL SPECIFICATION SHEET CABLE, SPECIAL PURPOSE, ELECTRICAL, TWO PAIRS OF 25 (78 X 33) AWG, ONE PAIR INDIVIDUALLY SHIELDED This specification is approved for use by all Departments and Agencies of the Department of Defense.
2、The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-49285. FIGURE 1. Cable illustration. AMSC N/A FSC 6145 INCH-POUND Inactive for new design after 16 June 1997. Provided by IHSNot for ResaleNo reproduction or networking permitted without
3、 license from IHS-,-,-MIL-DTL-49285/28A 2 Engineering information: (see table I and figure 1). Note: Not for aerospace use. TABLE I. Description, electrical. Electrical characteristics Requirements Nominal capacitance between conductors Nominal capacitance between the conductor and the shield with o
4、ne conductor tied to the shield Continuous working voltage Continuous working voltage between adjacent shields Shield dc resistance 25 pF/ft (picofarads/foot) 40 pF/ft 400 V rms maximum between conductors 28 ohms/1,000 feet maximum 48.0 ohms/1,000 feet maximum TABLE II. Description, physical. Compon
5、ents Construction details Number of pairs Conductor type and wire size Conductor stranding Conductor insulation Conductor insulation thickness Drain wire type and size Drain wire stranding Jacket material Jacket thickness Finished cable diameter Cable style (UL) Tensile strength (jacket) Elongation
6、(jacket) Overall cabling lay lengths Two pairs one pair individually shielded Stranded 25 AWG 7 X 33 AWG 3 tinned copper 4 tinned coated copper clad steel Polyethylene 0.013 inch nominal thickness Stranded 25 AWG 7 X 33 AWG 3 tinned copper 4 tinned coated copper clad steel Polyvinyl chloride 0.019 i
7、nch 0.174 inch maximum outside diameter Not applicable 2,000 pounds per square inch minimum 150 percent minimum 8.0 twists per foot 10 percent Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-49285/28A 3 REQUIREMENTS: Design and construction:
8、(see table II): Shield location and orientation. This cable consists of a shielded pair and an unshielded pair all enclosed by an overall shield. The polyester aluminum shield associated with the individually shielded pair is to be located on the outer circumference of the pair with the aluminum foi
9、l side outward. Insulation on the interior of the shield is to be complete with no aluminum available for contact. The overall shield encompasses the individually shielded pair and the unshielded pair. The overall shield insulation on the exterior of the shield is to be complete with no aluminum foi
10、l side inward. Shield color code. The shield colors shall be blue. Drain wire location. The drain wire is to be spirally located between the noise reducing tape and the aluminum foil shield, and is to be in continuous contact with the aluminum surface of the foil shield and the noise reducing tape t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILDTL4928528A2010CABLESPECIALPURPOSEELECTRICALTWOPAIRSOF2578X33AWGONEPAIRINDIVIDUALLYSHIELDEDPDF

链接地址:http://www.mydoc123.com/p-690846.html