《DLA MIL-DTL-3786 20 K-2010 SWITCH ROTARY CLOSED CONSTRUCTION EXPLOSION PROOF FLUX SEAL 500 INCH DIAMETER 200 AMPERE STYLE SR20.pdf》由会员分享,可在线阅读,更多相关《DLA MIL-DTL-3786 20 K-2010 SWITCH ROTARY CLOSED CONSTRUCTION EXPLOSION PROOF FLUX SEAL 500 INCH DIAMETER 200 AMPERE STYLE SR20.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、AMSC N/A FSC 5930 INCH-POUND MIL-DTL-3786/20K 15 April 2010 SUPERSEDING MIL-DTL-3786/20J 26 March 2003 DETAIL SPECIFICATION SHEET SWITCH, ROTARY, CLOSED CONSTRUCTION, EXPLOSION PROOF, FLUX SEAL, .500 INCH DIAMETER, .200 AMPERE, STYLE SR20 This specification is approved for use by all Departments and
2、 Agencies of the Department of Defense. The requirements for acquiring the switches described herein shall consist of this specification sheet and MIL-DTL-3786. FIGURE 1. Dimensions and configurations. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-
3、MIL-DTL-3786/20K 2 FIGURE 1. Dimensions and configurations - Continued.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-3786/20K 3 Inches mm Inches mm Inches mm .001 0.03 .020 0.51 .210 5.33 .002 0.05 .031 0.79 .219 5.56 .003 0.08 .032 0.81 .2
4、50 6.35 .004 0.10 .050 1.27 .260 6.60 .005 0.13 .065 1.65 .500 12.70 .007 0.18 .093 2.36 .576 14.63 .015 0.38 .125 3.18 .625 15.88 .203 5.16 .713 18.11 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. Unless otherwise specified, tolerances are .005
5、 (0.13 mm) and 3 degrees on angles (noncummulative). 4. Shaft flat angle A is the angle between a line through the center of the shaft perpendicular to the mounting bushing flats and another line through the center of the shaft perpendicular to the mounting bushing flats and another line through the
6、 center of the shaft and perpendicular to the shaft flat with switch in position one. For slotted switches, the slot is in line with the point of contact for pole number one. 5. Position number one and terminal number one coincide. FIGURE 1. Dimensions and configurations - Continued. Provided by IHS
7、Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-3786/20K 4 REQUIREMENTS: Dimensions and configuration: See figure 1. Angle A of 15 for switches of 30 angle of throw, 18 for switches of 36 angle of throw, 22.5 for switches of 45 angle of throw, 30 for switch
8、es of 60 angle of throw, and 45 for switches of 90 angle of throw. Angle of throw: 30, 36, 45, 60, 90. Construction styles: Symbols E, F, J, and K. Insulation: Symbol P (plastic). Mounting hardware: Each switch shall be provided with one corrosion-resistant steel hexagon nut, .089 .010 inch (2.26 mm
9、 0.254 mm) thick by .375 inch (9.53 mm) across the flats and one internal-toothed lockwasher, .402 .006 (10.21 mm .152 mm) outside diameter. Temperature-life characteristic: B (25,000 cycles) (-65C and +85C). Vibration grade: 3 (10 Hz to 2,000 Hz). Shock symbol: B (medium and high impact). Altitude:
10、 C (70,000 feet). Terminal strength (pull): A force of 1.5 pounds shall be applied to the terminals. Terminal marking: Switches may be marked with terminal numbers on side of switch. Stop strength: Stops shall withstand a force of 7.5 inch-pounds. Flux seal: Applicable when specified in the Part or
11、Identifying Number (PIN). Low level circuit life: Applicable when specified in PIN. Positive shaft grounding: Applicable when specified in PIN. Rotational torque: The minimum and maximum value of torque determined for shaft rotation shall be within limits specified in table I. TABLE I. Rotational-to
12、rque limits. Torque (in-lb) Temperature Minimum Maximum Room 0.5 1.5 Minimum 0.5 2.0 Life (rotational): The test loads for the applicable circuit conditions shall be as specified in table II. Each of the loads, specified for the applicable environmental condition, shall be switched by at least one r
13、otor contact of the switch. Low level circuit life is applicable as specified by PIN. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-3786/20K 5 TABLE II. Electrical loads. Environmental condition Lamp load (tungsten) Inductive load Resistive
14、 load mA V dc mA V dc mA Volts At atmospheric pressure 1/ 100 28 30 28 200 28 dc 75 115 V rms 60 Hz At reduced barometric pressure - - - - 200 28 dc 75 115 V rms 60 Hz 1/ The contact resistance (applicable to ac and dc), after life test, shall not exceed 50 milliohms. Dielectric withstanding voltage
15、: The magnitude of test voltage for the dielectric withstanding voltage shall be 600 V ac at temperature pressure and 250 V ac at reduced pressure. Test procedure on lamp load at atmospheric: The test procedure on lamp at atmospheric pressure shall be as follows: Test potential and load: One pole on
16、 four switches, each for atmospheric and at reduced barometric pressure, shall be energized by the specified lamp load. A common terminal and one selected terminal shall be arranged to be “on” once per cycle. The next selected terminal shall be unloaded. Suitable means shall be provided to indicate
17、when contacts have failed to make and break. Ordering data: Acquisition documents should specify the following: a. Title, number, and date of this specification sheet, and the military PIN as listed in table III, example A, or table IV, table V, and table VI, example B. b. For switches not listed in
18、 table III, table IV, table V, and table VI, acquisition shall be in accordance with the ordering data of MIL-DTL-3786 (for switches covered by specification sheets but not by military PINs). c. Switches covered are style SR20 units. Provided by IHSNot for ResaleNo reproduction or networking permitt
19、ed without license from IHS-,-,-MIL-DTL-3786/20K 6 PIN: The PIN shall be assigned using example A, which consists of a dash number from table III, and appropriate suffix letter as required. If the desired characteristics are not defined, the PIN shall be assigned by using the code letters from table
20、 IV, table V, and table VI as described in example B illustrated below: Example A: Nonflux-sealed, slotted terminal switches M3786/20-351 T G L Switching characteristics (see table III) Add the letter T when a slotted shaft is required Add the letter G if positive shaft grounding is required Add the
21、 letter L for low level requirement NOTE: M3786/351TGL identifies a nonflux-sealed rotary switch of construction E, temperature-life characteristic B, a 45 angle of throw, two poles per deck, three positions, nonshorting switching characteristics, slotted shaft, with low level and ground shaft. Exam
22、ple B: Flux-sealed switches: M3786/20-G E CL Switching characteristics, type of shaft and length of housing (see table IV) Type construction, low level capability shaft grounding, and type of termination (see table V) Angle of throw, poles per deck and number of positions per pole (see table VI) NOT
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILDTL378620K2010SWITCHROTARYCLOSEDCONSTRUCTIONEXPLOSIONPROOFFLUXSEAL500INCHDIAMETER200AMPERESTYLESR20PDF

链接地址:http://www.mydoc123.com/p-690657.html