DLA MIL-DTL-2211 F-2008 TABLE LAUNDRY FOLDING 3 BY 8 FEET《3 8脚的折叠洗衣桌》.pdf
《DLA MIL-DTL-2211 F-2008 TABLE LAUNDRY FOLDING 3 BY 8 FEET《3 8脚的折叠洗衣桌》.pdf》由会员分享,可在线阅读,更多相关《DLA MIL-DTL-2211 F-2008 TABLE LAUNDRY FOLDING 3 BY 8 FEET《3 8脚的折叠洗衣桌》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、AMSC N/A FSC 3510 MIL-DTL-2211F 29 JULY 2008 SUPERSEDING MIL-T-2211E 21 JUNE 1973 DETAIL SPECIFICATION TABLE, LAUNDRY, FOLDING, 3 BY 8 FEET This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 This specification covers one type and size of
2、 folding laundry table (see 6.1). 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in section 3, 4, or 5 of this standard. This section does not include documents cited in other sections of this standard or recommended for additional information or as examples.
3、 While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements of documents cited in sections 3, 4, or 5 of this standard, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications, Standards
4、, and handbooks. The following specifications, standards and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. FEDERAL SPECIFICATIONS QQ-S-698 Steel, Sheet and Strip, Low C
5、arbon TT-C-490 Chemical Conversion Coatings and Pretreatments for Ferrous Surfaces (Base for Organic Coatings) FEDERAL STANDARDS FED-STD-595/24084 Green, Semigloss DEPARTMENT OF DEFENSE STANDARDS MIL-STD-130 Identification Marking of U.S. Military Property (Copies of these documents are available on
6、line at http:/assist.daps.dla.mil. or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) Comments, suggestions, or questions on this document should be addressed to Defense Supply Center Philadelphia (DSCP), ATTN: DSCP-NASA, 700 Robbins Avenu
7、e, Philadelphia, PA 19111-5096 or e-mail to dscpg Assembly 5-13-2499 Table, Laundry, Folding; Details (Copies of these drawings are available from the US Army Natick Research and Development Center, 15 Kansas St., Natick, MA 01760.) US DEPARTMENT OF COMMERCE Product Standard PS 1 Structural Plywood
8、(Copies of this document are available online at http:/ts.nist.qov/docvps or from the Standards Services Division, National Institute of Standards and Technology, 100 Bureau Drive, MS 2150, Gaithersburg, MD 20899-2150.) 2.3 Non-Government publications. The following documents form a part of this spe
9、cification to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. AMERICAN SOCIETY FOR TESTING AND MATERIALS STANDARD ( ASTM) ASTM A575 Standard Specification for Steel Bars, Carbon, Merchant Quality, M -Grades ASTM
10、B209 Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate ASTM D4690 Standard Specification for Urea-Formaldehye Resin Adhesives (Copies o f these documents are available from http:/www.astm.org or ASTM International, 100 Barr Harbor Drive, W. Conshohocken, PA 19428-2959.) AMERICAN
11、 SOCIETY FOR QUALITY (ASQ) ASQ Z1.4 Sampling Procedures and Tables for Inspection by Attributes (Copies of this document are available from http:/www.asq.org or the American Society for Quality, 611 East Wisconsin Avenue, Milwaukee, WI 53202.) MASTER PAINTERS INSTITUTE (MPI) MPI # 28 Varnish, Marine
12、 Spar, Exterior, Gloss (MPl Gloss Level 6) (Copies of this document are available from http:/.) 2.4 Order of precedence. Unless otherwise noted herein or in the contract, in the event of a conflict between the text of this document and the reference cited herein, the text of this document takes prec
13、edence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-2211F 33.1 First article. When specified (see
14、 6.2), the supplier shall furnish a sample for first article inspection and approval (see 4.2 and 6.3). 3.2 Materials. Materials not definitely specified shall be of the quality normally used for the purpose in commercial practical. 3.2.1 Plywood. Plywood used for the tabletop and battens shall be e
15、xterior type, grade A-B, sanded two sides, conforming to group 1 of Product Standard PS 1. 3.2.2 Aluminum and steel angles and shapes. 3.2.2.1 Aluminum angles. Aluminum angles shall be fabricated of alloy 3003 conforming to the requirements of ASTM B209. 3.2.2.2 Steel, bar size shapes. Bar size shap
16、es shall conform to ASTM A575 or if formed from steel sheet or strip shall conform to QQ-S-698. 3.2.3 Hardware. Nuts and bolts, wing nuts, wood screws, washers, rivets, and cotter pins shall be standard commercial products, fabricated from steel and except for wood screws shall be zinc plated. 3.2.4
17、 Enamel. Enamel shall be a combination of air-drying and baking enamel that provides a smooth, semigloss, possessing excellent corrosion-inhibiting properties. The color shall be olive drab 24084 conforming to FED-STD-595. 3.2.5 Varnish, spar. Spar varnish shall conform to the requirements of MPI #
18、28. 3.2.6 Adhesive. Adhesive shall be urea-resin-type conforming to ASTM D4690. 3.3 Construction. The construction of all components and assemblies of the item covered by this specification shall conform to requirements herein and the design, details, dimensions, material classification and sizes sp
19、ecified on Drawing 5-13-2498. 3.3.1 Top. The top shall be plywood specified in 3.2.1 and sanded smooth. 3.3.1.1 Reinforcing and edging. The top shall be reinforced with steel angles specified in 3.2.2.2 and securely held to plywood top with wood screws. All edges of top shall be protected with alumi
20、num angles specified in 3.2.2.1, and securely held to plywood top with wood screws. 3.3.2 Battens. The battens shall be plywood specified in 3.2.1 and with all sides and edges sanded smooth. Battens shall be fastened to plywood top with adhesive specified in 3.2.6 and securely held in place with woo
21、d screws. 3.3.3 Hinges. Angles and channels forming hinges shall be firmly bolted through the battens and the top with 3/8-inch carriage bolts, countersunk into the top and the nuts tightly drawn against lock washers. 3.3.4 Legs end braces. The legs, stretchers and braces shall be formed from the st
22、eel sheet or strip specified in 3.2.2.2. 3.3.5 Finish. 3.3.5.1 Plywood. All exposed surfaces of plywood parts shall be cleaned of all dust and dirt. Exposed plywood shall be coated with spar varnish as specified in 3.2.5, before assembly and with a sufficient number of coats to produce a uniformly g
23、lossy appearance. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-2211F 43.3.5.2 Metal. All metal surfaces, except aluminum angles and the heads of carriage bolts, shall be prepared for painting according to type I or II of TT-C-490, and shal
24、l be coated with enamel specified in 3.2.4. 3.4 Marking for identification. Marking for identification of the tables shall be on the underside of the top and shall be in accordance with the requirements of MIL-STD-130. 3.5 Workmanship. Tables shall be free from defects such as fractures, splits, pun
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILDTL2211F2008TABLELAUNDRYFOLDING3BY8FEET38 折叠 洗衣 PDF

链接地址:http://www.mydoc123.com/p-690125.html