DLA DSCC-DWG-86087 REV D-2003 RELAYS ELECTROMAGNETIC PERMANENT MAGNET DRIVE 4PDT LOW LEVEL TO 5 AMPERES ALL WELDED HERMETICALLY SEALED (SIMILAR TO MIL-R-6106 28 EXCEPT FOR 12V DC C.pdf
《DLA DSCC-DWG-86087 REV D-2003 RELAYS ELECTROMAGNETIC PERMANENT MAGNET DRIVE 4PDT LOW LEVEL TO 5 AMPERES ALL WELDED HERMETICALLY SEALED (SIMILAR TO MIL-R-6106 28 EXCEPT FOR 12V DC C.pdf》由会员分享,可在线阅读,更多相关《DLA DSCC-DWG-86087 REV D-2003 RELAYS ELECTROMAGNETIC PERMANENT MAGNET DRIVE 4PDT LOW LEVEL TO 5 AMPERES ALL WELDED HERMETICALLY SEALED (SIMILAR TO MIL-R-6106 28 EXCEPT FOR 12V DC C.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、 REVISIONS LTR DESCRIPTION DATE APPROVED A Changed manufacturers eligibility. 23 Mar 1987 Steven. Searcy B Changes in accordance with NOR 5945-R005-96. 13 Feb 1996 David E. Moore C Technical and editorial changes throughout. 12 May 1998 David E. Moore D Validation and update. 17 Sep 2003 Kendall Cot
2、tongim Prepared in accordance with ASME Y14.100 Selected item drawing REV PAGE REV PAGE REV D D D D D D D REV STATUS OF PAGES PAGES 1 2 3 4 5 6 7 PMIC N/A PREPARED BY Richard A. Yannitti DESIGN ACTIVITY DEFENSE ELECTRONICS SUPPLY CENTER DAYTON, OH 45444-5000 CHECKED BY James R. Martin APPROVED BY St
3、even B. Searcy TITLE RELAYS, ELECTROMAGNETIC, PERMANENT MAGNET DRIVE, 4PDT, LOW LEVEL TO 5 AMPERES, ALL WELDED, HERMETICALLY SEALED (SIMILAR TO MIL-R-6106/28 EXCEPT FOR 12V DC COIL AND INVERTED STUD MOUNT) SIZE A CODE IDENT. NO. 14933 DWG NO. 86087 Original date of drawing 2 May 1986 REV D PAGE 1 OF
4、 7 AMSC N/A 5945-E117 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.CURRENT DESIGN ACTIVITY CAGE CODE 037Z3 DEFENSE LOGISTICS AGENCY DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43216-5000 Provided by IHSNot for ResaleNo reproduction or networking permitted withou
5、t license from IHS-,-,-DEFENSE ELECTRONICS SUPPLY CENTER DAYTON, OHIO SIZE A CODE IDENT NO. 14933 DWG NO. 86087 REV D PAGE 2 1. SCOPE 1.1 Scope. This drawing describes the requirements for a hermetically sealed electromechanical relay supplied to the requirements of an established reliability versio
6、n of MIL-PRF-83536/5 (see 6.6), except as noted herein. 1.2 Part or Identifying Number (PIN). The complete PIN shall be as follows: 86087 -001 | | | | Drawing Dash number number 2. APPLICABLE DOCUMENTS 2.1 Government documents. 2.1.1 Specifications, standards, and handbooks. The following specificat
7、ions, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those listed in the issue of the Department of Defense Index of Specifications and Standards (DoDISS) and supplement thereto, cited in the solicit
8、ation (see 6.3). SPECIFICATIONS DEPARTMENT OF DEFENSE MIL-PRF-83536 - Relays, Electromagnetic, Established Reliability, 25 Amperes and Below, General Specification For. MIL-PRF-83536/5 - Relays, Electromagnetic, Established Reliability, 4PDT, Low Level to 5 Amperes, Permanent Magnet Drive, Hermetica
9、lly Sealed, All Welded, DC Coils. STANDARDS DEPARTMENT OF DEFENSE MIL-STD-202 - Test Method Standard Electronic and Electrical Component Parts. (Unless otherwise indicated, copies of federal and military specifications, standards, and handbooks are available from the Document Automation and Producti
10、on Service, Building 4D (DPM-DODSSP), 700 Robbins Avenue, Philadelphia, PA 19111-5094.) 2.2 Order of precedence. In the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes app
11、licable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Item requirements. The individual item requirements shall be in accordance with MIL-PRF-83536, MIL-PRF-83536/5 and as specified herein. 3.2 Interface and physical dimensions. The interface and physical di
12、mensions shall be as specified in MIL-PRF-83536, MIL-PRF-83536/5, and herein (see figure 1). 3.2.1 Design documentation. The design documentation shall be in accordance with MIL-PRF-83536 unless otherwise specified in the contract or purchase order, and shall be retained by the manufacturer and avai
13、lable for review by the acquiring activity or contractor upon request. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DEFENSE ELECTRONICS SUPPLY CENTER DAYTON, OHIO SIZE A CODE IDENT NO. 14933 DWG NO. 86087 REV D PAGE 3 3.3 Electrical characteristic
14、s. Relays shall meet all electrical characteristics as specified in MIL-PRF-83536/5 and herein. 3.3.1 Coil data and operational data. See table I. 3.3.2 Contact data and load rating. See MIL-PRF-83536/5. 3.3.3 Operate time. 6 milliseconds maximum with rated coil voltage 25C. 3.3.4 Release time. 6 mi
15、lliseconds maximum from rated coil voltage 25C. 3.3.5 Contact bounce. 1.0 millisecond maximum. 3.3.6 Break bounce normally open contacts only. 0.1 millisecond maximum. 3.3.7 Overload current. 20 amperes dc, 30 amperes ac. 3.3.8 Rupture current. 25 amperes dc, 40 amperes ac. 3.4 Physical. Physical re
16、quirements of the relay shall be as specified in MIL-PRF-83536/5 and herein. 3.4.1 Mounting studs. The mounting studs shall be corrosion resistant steel. 3.4.2 Dimensions and configuration. See figure 1. TABLE I. Operating characteristics. Coil Data At 25 C Over temperature range Maximum pickup volt
17、age Coil voltage (V dc) 1/ Coil resistance (ohms) Specified pickup voltage Specified hold voltage Specified dropout voltage Specified pickup voltage Specified hold voltage Specified dropout voltage High temperature Continuous current Rated Max minimum (V dc) 2/ (V dc) 2/ (V dc) 2/ (V dc) 2/ (V dc) 2
18、/ (V dc) 2/ test test 12 14.5 70 6.6 3.3 0.75 9.0 4.5 0.5 9.9 11.25 1/ CAUTION: The use of any coil voltages less than the rated coil voltage will compromise the operation of the relay. 2/ Pickup, hold, and dropout voltages as shown are for test purposes only and are not to be used for design criter
19、ia. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DEFENSE ELECTRONICS SUPPLY CENTER DAYTON, OHIO SIZE A CODE IDENT NO. 14933 DWG NO. 86087 REV D PAGE 4 Figure 1. Outline drawing and dimensions. Provided by IHSNot for ResaleNo reproduction or networ
20、king permitted without license from IHS-,-,-DEFENSE ELECTRONICS SUPPLY CENTER DAYTON, OHIO SIZE A CODE IDENT NO. 14933 DWG NO. 86087 REV D PAGE 5 Inches mm Inches mm .002 0.05 .224 5.69 .032 0.81 .250 6.35 .040 1.02 .375 9.53 .065 1.65 .500 12.70 .112 2.84 .640 16.26 .210 5.33 .810 20.57 Notes: 1. D
21、imensions are in inches. 2. Metric equivalents are given for general information only. 3. Unless otherwise specified, tolerance is .010 (0.25 mm). 4. There shall be affixed to the relay a suitable legible circuit diagram that identifies each terminal location specified. 5. This relay is polarized mo
22、nostable. 6. This relay shall not operate or be damaged by reverse polarity. Semiconductors shall not be used for this purpose. 7. Permanent magnet drive consists of a permanent magnet with its flux path switched and combined with the electromagnetic flux. Figure 1. Outline drawing and dimensions Co
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLADSCCDWG86087REVD2003RELAYSELECTROMAGNETICPERMANENTMAGNETDRIVE4PDTLOWLEVELTO5AMPERESALLWELDEDHERMETICALLYSEALEDSIMILARTOMILR610628EXCEPTFOR12VDCCPDF

链接地址:http://www.mydoc123.com/p-688824.html