1、 REVISIONS LTR DESCRIPTION DATE APPROVED Prepared in accordance with ASME Y14.100 Source control drawing REV STATUS OF PAGES REV PAGES 1 2 3 4 5 6 7 8 9 PMIC N/A PREPARED BY Patrick Kyne DESIGN ACTIVITY DEFENSE SUPPLY CENTER COLUMBUS, COLUMBUS, OH Original date of drawing CHECKED BY John Bonitatibus
2、 TITLE FILTER, EMI, HYBRID, 3 Amp 9 April 2010 APPROVED BY Michael A. Radecki SIZE A CODE IDENT. NO. 037Z3 DWG NO. 10015 REV PAGE 1 OF 9 AMSC N/A 5915-E088 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DEFENSE SUPPLY CENTER COLUMBUS, COLUMBUS, OHIO
3、 SIZE A CODE IDENT NO. 037Z3 DWG NO. 10015 REV PAGE 2 1. SCOPE 1.1 Scope. This drawing describes the requirements for hybrid microcircuit electromagnetic interference (EMI) suppression filters to be processed in accordance with MIL-PRF-38534. Two product assurance classes consisting of class H (mili
4、tary high reliability) and class K (space application) and a choice of case outlines and lead finishes are reflected in the Part or Identifying Number (PIN). When available, a choice of radiation hardness assurance (RHA) levels, are reflected in the PIN. 1.2 Part or Identifying Number (PIN). The PIN
5、 is shown in the following example: 10015 - 01 H X X Drawing RHA Device type Device class Case Lead number designator (See 1.2.2) designator outline finish (See 1.2.1) (See 1.2.3) (See 1.2.4) (See 1.2.5) 1.2.1 Radiation hardness assurance (RHA) designator. Device classes H and K RHA marked devices m
6、eet the MIL-PRF-38534 specified RHA levels and should be marked with the appropriate RHA designator. A dash (-) indicates a non-RHA device. 1.2.2 Device types. The device type identifies the circuit function as follows: Device type Generic number Circuit function 01 FMCE-0328 EMI filter, 3 A 1.2.3 D
7、evice class designator. The device class designator is a single letter identifying the product assurance level as follows: Device class Device requirements documentation K Highest reliability class available. This level is intended for use in space applications. Certification and qualification to MI
8、L-PRF-38534 is required. H Standard military reliability level. This level is intended for use in applications where non-space high reliability devices are required. Certification and qualification to MIL-PRF-38534 is required. 1.2.4 Case outline. The case outline is designated in MIL-STD-1835, and
9、as follows: Outline letter Case outline X 1.460” x 1.130” x .330” (see figure 1) Z 2.005” x 1.130” x .330” flanged case (see figure 2) 1.2.5 Lead finish. The lead finish is as specified in MIL-PRF-38534 for classes H and K. Finish letter “X” will not be marked on the filter or its packaging. The “X”
10、 designation is used when lead finishes A, B, or C is considered acceptable and interchangeable without preference. 1.3 Absolute maximum ratings. 1/ Input voltage - -0.5 to +80 V dc Input current - 3 A Power dissipation - 2.25 W Lead temperature (soldering, 10 seconds) - +300C Storage temperature -
11、-65C to +150C 1/ Stresses above the absolute maximum ratings may cause permanent damage to the device. Extended operation at the maximum levels may degrade performance and affect reliability. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DEFENSE SU
12、PPLY CENTER COLUMBUS, COLUMBUS, OHIO SIZE A CODE IDENT NO. 037Z3 DWG NO. 10015 REV PAGE 3 1.4 Recommended operating conditions. Input voltage - -0.5 to +50 V dc Case operating temperature range - -55C to +125C 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in
13、 sections 3 and 4 of this drawing. This section does not include documents cited in other sections of this drawing or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all
14、specified requirements of documents in sections 3 and 4 of this drawing whether or not they are listed here. 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein. U
15、nless otherwise specified, the issues of these documents are those cited in the solicitation or contract (see 6.2). DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-PRF-38534 - Hybrid Microcircuits, General Specification for. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-883 - Test Methods and Procedures for Micr
16、oelectronics. (Copies of these documents are available online at https:/assist.daps.dla.mil/quicksearch/ or from the Standardization Document Order Desk, Building 4D, 700 Robbins Avenue, Philadelphia, PA 19111-5094.) 2.3 Order of precedence. Unless otherwise noted herein or in the contract, in the e
17、vent of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Item requirements. The in
18、dividual item requirements shall be in accordance with MIL-PRF-38534 and as specified herein. 3.2 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as specified in MIL-PRF-38534 and as specified herein. 3.2.1 Case outline. The case outline shal
19、l be in accordance with 1.2.4 herein and figures 1 and 2. 3.2.2 Terminal connections. The terminal connections shall be as specified on figure 3. 3.3 Pure tin prohibition. The use of pure tin as an underplate or final finish in the internal or external construction of the filter and the terminations
20、 is prohibited. This includes the discrete devices and solders used internal to the case. Tin shall be alloyed with a minimum of 3 percent lead, by mass. The use of tin alloys other than lead is permissible as specified in APPENDIX E of MIL-PRF-38534. 3.4 Electrical performance characteristics. Unle
21、ss otherwise specified herein, the electrical performance characteristics are as specified in table I and shall apply over the full specified operating temperature range. 3.5 Electrical test requirements. The electrical test requirements shall be the subgroups specified in table II. The electrical t
22、ests for each subgroup are defined in table I. 3.6 Marking. Marking shall be in accordance with MIL-PRF-38534. The part shall be marked with the PIN listed in 1.2 herein. In addition, the manufacturers PIN may also be marked as listed on QML-38534. Provided by IHSNot for ResaleNo reproduction or net
23、working permitted without license from IHS-,-,-DEFENSE SUPPLY CENTER COLUMBUS, COLUMBUS, OHIO SIZE A CODE IDENT NO. 037Z3 DWG NO. 10015 REV PAGE 4 3.7 Manufacturer eligibility. To be eligible for listing as an approved source of supply, the manufacturer shall be certified and qualified to MIL-PRF-38
24、534. In addition to the general requirements of MIL-PRF-38534, the manufacturer of the part described herein shall maintain the electrical test data (variables format) from the initial quality conformance inspection group A lot sample, produced on the certified line, for each device type listed here
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLADSCCDWG100152010FILTEREMIHYBRID3AMPPDF