DLA A-A-59177-1998 MORTAR REFRACTORY HEAT-SETTING AND AIR-SETTING WET AND DRY TYPES《湿型及干型热定式及常温凝固式耐火砌泥》.pdf
《DLA A-A-59177-1998 MORTAR REFRACTORY HEAT-SETTING AND AIR-SETTING WET AND DRY TYPES《湿型及干型热定式及常温凝固式耐火砌泥》.pdf》由会员分享,可在线阅读,更多相关《DLA A-A-59177-1998 MORTAR REFRACTORY HEAT-SETTING AND AIR-SETTING WET AND DRY TYPES《湿型及干型热定式及常温凝固式耐火砌泥》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、 A-A-57177 9999974 0177202 24T = INCH-POUND A-A-591 77 20 March 1998 SUPERSEDING 18 May 1977 HH-M-622D COMMERCIAL ITEM DESCRIPTION MORTAR, REFRACTORY: HEAT-SETTING AND AIR-SETTING WET AND DRY TYPES The General Services Administration has authorized the use of this commercial item description for all
2、 federal agencies. 1. SCOPE. This commercial item description (CID) covers heat-setting and air-setting refractory mortars for use in bonding refractory brick. 2. CLASSIFICATION. The refractory mortar shall be of the following types and classes. The type and class to be furnished shall be as specifi
3、ed (see 7.2(b). Tme. Type I - Wet air-setting mortar Type II - Dry air-setting mortar Type III - Heat-setting mortar Class. Class 1 - Super duty Class 2 - High duty Class 3 - Medium duty Beneficial comments, recommendations, additions, deletions, clarifications, etc., and any other data which may im
4、prove this document should be sent to: Supply Defense Center Richmond, ATTN: DSCR-VBD, 8000 Jefferson Davis Highway, Richmond, VA 23297-5610. AMSC NIA FSC 9350 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Licensed by Information Handling Services A-A-59177 999997
5、4 0377203 3Bb 2 3 t 2730 “F (1 500 OC) 2550 “F (1400 OC) A-A-59177 Class 1 2 3. SALIENT CHARACTERISTICS Heating schedule ASTM C 113 Schedule F Schedule F Pyrometric cone equivalent ConeNo. 31 (3061 “F, 1683 OC) Cone No. 27 (2984 9,1640 OC) 3.1 General requirements. The refiactory mortar shall be gro
6、und to a particle size such that not more than 0.5 percent shall be retained on a United States Standard Sieve No. 20 and not more than 5.0 percent shall be retained on a United States Standard Sieve No. 40. The particle size shall be tested in accordance with the wet sieve analysis in sections 6 th
7、rough 9 of ASTM C 92. The mortar shall have a minimum modulus of rupture of 500 pounds per square inch when tested in accordance with ASTM C 198. 3.2 Twe I and trpe II mortars. The type I and type II mortars shail come premixed and ready for use. The maximum water content shall be 25 percent when te
8、sted in accordance with ASTM C 92. The mortar shall meet the reIactoriness requirements of ASTM C 199 when tested at the minimum temperature specified in table I. TABLE I. Tyes I and II refractoriness test temperatures. _ 1 Class 1 Temperature(minimum) -1 I 1 I 2910 “F (1600 OC) I 3.3 Tme III mortar
9、s. The type III mortars shall meet the pyrometric cone equivalent of table II when tested in accordance with ASTM C 24. The type III mortars shall be heated using the heating schedule specified in table II and ASTM C 113. TABLE II. Tme III mortar reauirements. I 3 I ConeNo. 23 (2921 %, 1605 OC) I Sc
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAAA591771998MORTARREFRACTORYHEATSETTINGANDAIRSETTINGWETANDDRYTYPES 干型热 定式 常温 凝固 耐火 PDF

链接地址:http://www.mydoc123.com/p-687140.html