DLA A-A-55569 3 C-2011 FUSE INCLOSED LINK SLOW BLOWING 20 AMPERES (A) THROUGH 80 A AUTOMOTIVE BLADE TYPE.pdf
《DLA A-A-55569 3 C-2011 FUSE INCLOSED LINK SLOW BLOWING 20 AMPERES (A) THROUGH 80 A AUTOMOTIVE BLADE TYPE.pdf》由会员分享,可在线阅读,更多相关《DLA A-A-55569 3 C-2011 FUSE INCLOSED LINK SLOW BLOWING 20 AMPERES (A) THROUGH 80 A AUTOMOTIVE BLADE TYPE.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、AMSC N/A FSC 5920 INCH-POUND A-A-55569/3C 12 October 2011 SUPERSEDING A-A-55569/3B 5 October 2006 COMMERCIAL ITEM DESCRIPTION SPECIFICATION SHEET FUSE, INCLOSED LINK, SLOW BLOWING, 20 AMPERES (A) THROUGH 80 A, AUTOMOTIVE BLADE TYPE The General Services Administration has authorized the use of this c
2、ommercial item description (CID) for all federal agencies. The complete requirements for procuring the inclosed fuse links described herein shall consist of this document and the issue in effect of CID A-A-55569. CLASSIFICATION/PART OR IDENTIFICATION NUMBER (PIN). This commercial item description (C
3、ID) specification sheet uses a classification system which is included in the PIN as shown in the following example (see NOTES). AA55569 /03 - 001 CID number Applicable CID specification sheet (two digits) Dash number SALIENT CHARACTERISTICS. Interface and physical dimensions. Fuses supplied to this
4、 CID specification sheet shall be as specified herein, and shall meet the requirements of SAE J1888 for high current time lag electronic fuses (see figure 1). Ampere rating. The ampere rating shall be as specified in table I. Voltage rating. The voltage rating shall be 32 V dc maximum. Opening time.
5、 The opening time shall be as specified in table II. NOTES. PIN. The PIN should be used for Government purposes to buy commercial products to this CID specification sheet. See classification section for PIN format example. Provided by IHSNot for ResaleNo reproduction or networking permitted without
6、license from IHS-,-,-A-A-55569/3C 2 NOTES: 1. Dimensions are in inches. 2. Tolerance is .005 inch (0.13 mm), unless otherwise specified. FIGURE 1. Interface and physical dimensions. Inches mm Inches mm .002 0.05 .358 9.09 .008 0.20 .500 12.70 .032 0.82 1.161 29.49 .315 8.00 1.378 35.00 Provided by I
7、HSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-55569/3C 3 TABLE I. Electrical characteristics. CID dash number AA55569/03- Ampere rating Color code 1/ 001 20 Yellow 002 30 Green 003 40 Amber 004 50 Red 005 60 Blue 006 70 Tan 007 80 Natural 1/ Fuses are color
8、-coded for easy amperage identification. TABLE II. Rating versus opening time. Percent of rating Opening time maximum/minimum (seconds) 20 A 30 A 40 A 50 A 60 A 70 A 80 A 135 1,800 60 1,800 60 1,800 60 1,800 60 1,800 60 3,600 60 3,600 60 200 20 4 30 6 40 8 50 10 60 15 60 4 60 4 350 2 .7 4 1 5 1.4 6
9、1.7 7 2 2 .2 2 .2 600 1 .15 1 .20 1 .20 1 .20 1 .20 .15 .04 .15 .04 Source of documents. Other Publications SOCIETY OF AUTOMOTIVE ENGINEERS (SAE) SAE J1888 - High Current Time Lag Electric Fuses, Standard. (Copies of this document is available online at http:/www.sae.org/ or from the Society of Auto
10、motive Engineers, 400 Commonwealth Drive, Warrendale, PA 15096-0001.) (Industry association specifications and standards are generally available for reference from libraries. They are also distributed among technical groups and using Federal agencies.) Provided by IHSNot for ResaleNo reproduction or
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAAA555693C2011FUSEINCLOSEDLINKSLOWBLOWING20AMPERESATHROUGH80AAUTOMOTIVEBLADETYPEPDF

链接地址:http://www.mydoc123.com/p-686973.html