1、A-A-55L35 = 9999974 OL20BL3 b89 I -INCB-POUND 1 A-A-55 13 5 December 10, 1992 COMMERCIAL ITEM DESCRIPTION LIGHT, CHEMILUMINESCENT, 6 IN - 5 MIN - C The General Services Administration has authorized the use of this commercial item description. Abstract . This description covers a 5 minute 6 inch che
2、miluminescent light (commonly known as a light wand) used for a variety of lighting, marking, and identification purposes. Salient characteristics. 1. Color. The color of the chemiluminescent light described in this CID is orange. the Part Identification Number (PIN) paragraph of this CID. The color
3、 wand required shall be identified in Beneficial comments, recommendations, additions, deletions, clarifications, etc., and any data which may improve this document should be sent to: Commander, Space and Naval Warfare Command, ATTN: SPAWAR 003-114/031, Washington, DC 20363. FSC 6260 DISTRIBUTION ST
4、ATEMENT A. Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-5 5 13 5 2. Desisn. The chemiluminescent light shall be elongated having an overall length of 6 inches plus 0.043 minus 0.375 inche
5、s. The mid point diameter shall be no less than .500 inches and the wand shall have a flat base on one end. The diameter of the flat end shall not exceed -750 inches. The end opposite the flat base shall have a hole -188 inches nominal. Lightsticks shall have a tapered shape and shall be compatible
6、with the following accessory items; Lightstick Shield (NSN 6260-01-196-0637), Ground Stake (NSN 6260-01-230-8555), Flare, Surface Trip (NSN 6260-01-247-2937), Handle, six (6) inch (NSN 6260-01-255-3345), and Magnetic Base (NSN 6260-01-255-3346). Lightsticks shall be individually wrapped in an airtig
7、ht foil wrapper. 3. Interior. This chemiluminescent light specified in this Commercial Item Description shall produce a level of light intensity as specified in Table I for a specified length of time (5 minutes). 4. Material Safety Data Sheet. Manufacturer shall provide evidence in the form of a Mat
8、erial Safety Data Sheet (MSDS) (Fed-Std-313) that the components shall not be highly toxic, toxic, corrosive or irritant in terms of the definitions and tests in Code of Federal Regulations, Title 16, Part 1500 (Federal Hazardous Substances Act). exceed the data presented in Table I. After Ageing Te
9、st, luminance (foot lambert-hours) must meet or exceed data in Table II. Activated by manually flexing the plastic tube, breaking the inner vial and shaking to combine components. Plastic tube shall not leak and vial will not break when subjected to an external pressure equivalent to 30,000 feet at
10、75 degrees F in a vacuum chamber. Must withstand a free fall, while still in wrapper, from a height of 8.5 feet on a hard surface (concrete) without activating or leakage. 5. Test criteria. Luminance (foot lambert-hours) must meet or 6. Test conditions. a. Meter: Traceable to NIST. b. Aging Test - t
11、o be added at a future revision date. c. Temperature stabilization: Wands, while still in sealed foil wrappers, will be placed in test temperature for a minimum of one (1) hour before activation. d. Remove wand from sealed foil wrapper immediately before activation. Light wand shall be handled by ca
12、p end during testing. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-55135 m 9999974 0120815 451 m A-A-55 13 5 e. Activation method: Bend; agitate for five (5) seconds. f. Wands kept under cover or in darkness; may be exposed to a light during
13、 movement to and from light meter. g. All meter readings made in darkness. h. Meter kept at 75 degrees F for all tests. i. Temperature tolerances: plus or minus 2 F. j. Holder, wand test fixture in accordance with DGSC drawing, - k. Chemiluminescent lights shall be held in a vertical position- DGSCV
14、-91-03, Part Number 3. (Enclosure 1) with cap end down when light output measurement is made. 1. Ageing Test - test conditions to be added at a future date. Contractor certification. The contractor shall certify, and maintain objective quality evidence that the product offered to the Government meet
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAAA551351992LIGHTCHEMILUMINESCENT6IN5INC6IN5INC 化学 发光 PDF

链接地址:http://www.mydoc123.com/p-686540.html