DIN ISO 5832-1-2017 Implants for surgery - Metallic materials - Part 1 Wrought stainless steel (ISO 5832-1 2016)《外科植入物 金属材料 第1部分 锻造不锈钢(ISO 5832-1-2016)》.pdf
《DIN ISO 5832-1-2017 Implants for surgery - Metallic materials - Part 1 Wrought stainless steel (ISO 5832-1 2016)《外科植入物 金属材料 第1部分 锻造不锈钢(ISO 5832-1-2016)》.pdf》由会员分享,可在线阅读,更多相关《DIN ISO 5832-1-2017 Implants for surgery - Metallic materials - Part 1 Wrought stainless steel (ISO 5832-1 2016)《外科植入物 金属材料 第1部分 锻造不锈钢(ISO 5832-1-2016)》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、April 2017 English price group 8No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).ICS 11.040.40; 77.140.20!%cO*“2644407ww
2、w.din.deDIN ISO 5832-1Implants for surgery Metallic materials Part 1: Wrought stainless steel (ISO 58321:2016),English translation of DIN ISO 5832-1:2017-04Chirurgische Implantate Metallische Werkstoffe Teil 1: Nichtrostender Stahl (ISO 58321:2016),Englische bersetzung von DIN ISO 5832-1:2017-04Impl
3、ants chirurgicaux Produits base de mtaux Partie 1: Acier inoxydable corroy (ISO 58321:2016),Traduction anglaise de DIN ISO 5832-1:2017-04SupersedesDIN ISO 58321:200812www.beuth.deDocument comprises 12 pagesDTranslation by DIN-Sprachendienst.In case of doubt, the German-language original shall be con
4、sidered authoritative.03.17 A comma is used as the decimal marker. National Annex NA (informative) Bibliography 5Introduction .61 Scope . 72 Normative references 73 Terms and definitions . 74 Chemical composition . 84.1 Test samples 84.2 Cast analysis 85 Microstructure in the fully annealed conditio
5、n . 85.1 Grain size 85.2 Microstructure 85.3 Inclusion content. 96 Mechanical properties 96.1 Test pieces . 96.2 Tensile test 96.3 Gauge length 97 Test methods .9Bibliography .12Contents PageNational foreword 3DIN ISO 5832-1:2017-04 2 National foreword This standard (ISO 5832-1:2016) has been prepar
6、ed by Technical Committee ISO/TC 150 “Implants for surgery”, SC 1 “Materials”. The responsible German body involved in its preparation was DIN-Normenausschuss Feinmechanik und Optik (DIN Standards Committee Optics and Precision Mechanics), Working Committee NA 027-02-06 AA Implantatwerkstoffe. Atten
7、tion is drawn to the possibility that some of the elements of this document may be the subject of patent rights. DIN shall not be held responsible for identifying any or all such patent rights. The DIN Standards corresponding to the International Standards referred to in Clause 2 of this standard ar
8、e as follows: ISO 377 DIN EN ISO 377 ISO 439 DIN EN ISO 439 ISO 643 DIN EN ISO 643 ISO 6892-1 DIN EN ISO 6892-1 ISO 10714 DIN EN ISO 10714 DIN ISO 5832 consists of the following parts, under the general title Implants for surgery Metallic materials: Part 1: Wrought stainless steel Part 2: Unalloyed
9、titanium Part 3: Wrought titanium 6-aluminium 4-vanadium alloy Part 4: Cobalt-chromium-molybdenum casting alloy Part 5: Wrought cobalt-chromium-tungsten-nickel alloy Part 6: Wrought cobalt-nickel-chromium-molybdenum alloy Part 7: Forgeable and cold-formed cobalt-chromium-nickel molybdenum-iron alloy
10、 Part 8: Wrought cobalt-nickel-chromium-molybdenum-tungsten-iron alloy Part 9: Wrought high nitrogen stainless steel Part 11: Wrought titanium 6-aluminium 7-niobium alloy Part 12: Wrought cobalt-chromium-molybdenum alloy Part 14: Wrought titanium 15-molybdenum 5-zirconium 3-aluminium alloy DIN ISO 5
11、832-1:2017-04 3 Amendments This standard differs from DIN ISO 5832-1:2008-12 as follows: a) Clause 3 “Terms and definitions” and the term “original gauge length” from ISO 6892-1 have been added; b) Subclause 6.3 “Gauge length” has been revised so that the user of the standard has the possibility to
12、choose between different original gauge lengths; c) Tables 4 and 7 which showed the relation between gauge length and product type and between gauge length and thickness of the products have been deleted; d) in Table 6, ISO 437 as test method for carbon has been deleted as the standard has been with
13、drawn without replacement. Previous editions DIN 17443: 1977-10, 1986-04 DIN EN ISO 5832-1: 2000-08, 2008-12 DIN ISO 5832-1:2017-04 4 National Annex NA (informative) Bibliography DIN EN ISO 377, Steel and steel products Location and preparation of samples and test pieces for mechanical testing DIN E
14、N ISO 439, Steel and iron Determination of total silicon content Gravimetric method DIN EN ISO 643, Steels Micrographic determination of the apparent grain size DIN EN ISO 6892-1, Metallic materials Tensile testing Part 1: Method of test at room temperature DIN EN ISO 10714, Steel and iron Determina
15、tion of phosphorus content Phosphovanadomolybdate spectrophotometric method DIN ISO 5832-1:2017-04 5 IntroductionNo known surgical implant material has ever been shown to be completely free of adverse reactions in the human body. However, long-term clinical experience of the use of the material refe
16、rred to in this part of ISO 5832 has shown that an acceptable level of biological response can be expected when the material is used in appropriate applications.The following definitions apply in understanding how to implement an ISO International Standard and other normative ISO deliverables (TS, P
17、AS, IWA): “shall” indicates a requirement; “should” indicates a recommendation; “may” is used to indicate that something is permitted; “can” is used to indicate that something is possible, for example, that an organization or individual is able to do something.3.3.1 of the ISO/IEC Directives, Part 2
18、 (sixth edition, 2011) defines a requirement as an “expression in the content of a document conveying criteria to be fulfilled if compliance with the document is to be claimed and from which no deviation is permitted.”3.3.2 of the ISO/IEC Directives, Part 2 (sixth edition, 2011) defines a recommenda
19、tion as an “expression in the content of a document conveying that among several possibilities one is recommended as particularly suitable, without mentioning or excluding others, or that a certain course of action is preferred but not necessarily required, or that (in the negative form) a certain p
20、ossibility or course of action is deprecated but not prohibited.”DIN ISO 5832-1:2017-04 6Implants for surgery Metallic materials Part 1: Wrought stainless steel1 ScopeThis part of ISO 5832 specifies the characteristics of, and corresponding test methods for, wrought stainless steel for use in the ma
21、nufacture of surgical implants.NOTE 1 The mechanical properties of a sample obtained from a finished product made of this alloy can differ from those specified in this part of ISO 5832.NOTE 2 The alloy described in this part of ISO 5832 corresponds to UNS S31673 referred to in ASTM F138/ASTM F139 an
22、d to alloy code 1.4441 given in the withdrawn DIN 17443.2 Normative referencesThe following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DINISO583212017IMPLANTSFORSURGERYMETALLICMATERIALSPART1WROUGHTSTAINLESSSTEELISO583212016 外科 植入 金属材料 部分

链接地址:http://www.mydoc123.com/p-684736.html