DIN ISO 16000-27-2014 Indoor air - Part 27 Determination of settled fibrous dust on surfaces by SEM (scanning electron microscopy) (direct method) (ISO 16000-27 2014)《室内空气 第27部分 采用.pdf
《DIN ISO 16000-27-2014 Indoor air - Part 27 Determination of settled fibrous dust on surfaces by SEM (scanning electron microscopy) (direct method) (ISO 16000-27 2014)《室内空气 第27部分 采用.pdf》由会员分享,可在线阅读,更多相关《DIN ISO 16000-27-2014 Indoor air - Part 27 Determination of settled fibrous dust on surfaces by SEM (scanning electron microscopy) (direct method) (ISO 16000-27 2014)《室内空气 第27部分 采用.pdf(41页珍藏版)》请在麦多课文档分享上搜索。
1、November 2014Translation by DIN-Sprachendienst.English price group 16No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).IC
2、S 13.040.20!%$“2270193www.din.deDDIN ISO 16000-27Indoor air Part 27: Determination of settled fibrous dust on surfaces by SEM(scanning electron microscopy) (direct method) (ISO 16000-27:2014),English translation of DIN ISO 16000-27:2014-11Innenraumluftverunreinigungen Teil 27: Bestimmung von abgelag
3、erten Faserstuben auf Oberflchen mittels REM(Rasterelektronenmikroskopie) (direkte Methode) (ISO 16000-27:2014),Englische bersetzung von DIN ISO 16000-27:2014-11Air intrieur Partie 27: Dtermination de la poussire fibreuse dpose sur les surfaces par MEB(microscopie lectronique balayage) (mthode direc
4、te) (ISO 16000-27:2014),Traduction anglaise de DIN ISO 16000-27:2014-11www.beuth.deIn case of doubt, the German-language original shall be considered authoritative.Document comprises 41 pages11.14This standard has been included in the VDI/DIN Handbook on air quality, Volume 5.2DIN ISO 16000-27:2014-
5、11A comma is used as the decimal marker. Contents Page National foreword .3 National Annex NA (informative) Bibliography .5 Introduction .9 1 Scope 10 2 Normative references 10 3 Terms and definitions . 10 4 Symbols and abbreviations 12 4.1 Symbols 12 4.2 Abbreviations . 13 5 Principle 13 6 Apparatu
6、s and material . 13 6.1 Equipment and materials for adhesive tape sampling and preparation 13 6.2 Equipment and material for analysis . 14 7 Sampling . 14 7.1 Measurement planning . 14 7.2 Measurement objectives and sampling sites . 15 7.3 Number of samples . 16 7.4 Requirements on the sampled surfa
7、ce . 17 7.5 Sampling procedure 17 7.6 Sampling record 18 8 Analysis (SEM) . 19 8.1 Adjustment of the SEM . 19 8.2 Procedure . 19 8.3 Fibre classification by EDXA 22 9 Calculation and presentation of results 28 10 Record of analysis . 29 11 Measurement uncertainty . 29 11.1 General . 29 11.2 Random s
8、ample related deviation . 30 11.3 Deviations in analysis and weighting of the count results . 30 11.4 Detection limit 30 12 Applications and instructions for use . 31 12.1 General . 31 12.2 Sample requirements 31 12.3 Summary of the results for multiple individual samples. 32 Annex A (informative) E
9、xample of SEM structure counting form 33 Annex B (normative) Procedures for calibration and adjustment of the SEM 34 Annex C (informative) Random sample related deviation . 35 Annex D (informative) Example: using the method in an indoor environment. 39 Bibliography . 41 3DIN ISO 16000-27:2014-11Nati
10、onal foreword International technical regulation pertaining to indoor air This standard has been prepared by Technical Committee ISO/TC 146 “Air quality”, Subcommittee SC 6 “Indoor air” (Convenership and Secretariat: DIN, Germany). The responsible German body involved in its preparation was the Komm
11、ission Reinhaltung der Luft (KRdL) im VDI und DIN Normenausschuss (Commission on Air Pollution Prevention of VDI and DIN Standards Committee), Section IV Umweltmesstechnik. In addition to the legal units of measurement, this standard also uses the units “ppm” and “ppb”. It should, however, be noted
12、that the Gesetz ber Einheiten im Messwesen (German Law on units in metrology) prohibits the use of these units for official and commercial purposes in Germany. The indication of this unit solely serves to facilitate the communication with those countries where this unit is used (import-export busine
13、ss). General and substance-specific aspects which should be taken into account before or during measurements, as well as methods for determining individual substances or substance groups, and microorganisms in indoor air are described in the various parts of ISO 16000. The DIN Standard corresponding
14、 to the International Standard referred to in Clause 2 of this standard is as follows: ISO 22262-1 VDI 3866 Part 5 Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. DIN shall not be held responsible for identifying any or all such p
15、atent rights. This European Standard is based on VDI 3877 Part 1; it does not contradict the VDI Standard, nor does it contain any different approaches. National technical regulation pertaining to indoor air General conditions and other aspects to be taken into consideration when planning indoor air
16、 measurements are described for individual substances and substance groups in the VDI 4300 series (see also “National Annex NA”). Many of these served as the sole basis for parts of the ISO 16000 series (e.g. ISO 16000-1, ISO 16000-2, ISO 16000-5, ISO 16000-7, ISO 16000-12, ISO 16000-15, ISO 16000-1
17、6, ISO 16000-17, ISO 16000-18 and ISO 16000-26). The specific procedures (sampling, analysis) are described in the VDI 4301 series for individual substances and substance groups. Methods which can be used for both indoor and ambient air measurements are described in further VDI Guidelines. The DIN I
18、SO 16000 series and DIN EN ISO 16000 series consist of the following parts, under the general title Indoor air: DIN EN ISO 16000-1, General aspects of sampling strategy DIN EN ISO 16000-2, Sampling strategy for formaldehyde DIN ISO 16000-3, Determination of formaldehyde and other carbonyl compounds
19、in indoor air and test chamber air Active sampling method DIN ISO 16000-4, Determination of formaldehyde Diffusive sampling method DIN EN ISO 16000-5, Sampling strategy for volatile organic compounds (VOCs) DIN ISO 16000-6, Determination of volatile organic compounds in indoor and test chamber air b
20、y active sampling on Tenax TAsorbent, thermal desorption and gas chromatography using MS/FID DIN EN ISO 16000-7, Sampling strategy for determination of airborne asbestos fibre concentrations DIN ISO 16000-8, Determination of local mean ages of air in buildings for characterizing ventilation conditio
21、ns 4DIN ISO 16000-27:2014-11 DIN EN ISO 16000-9, Determination of the emission of volatile organic compounds from building products and furnishing Emission test chamber method DIN EN ISO 16000-10, Determination of the emission of volatile organic compounds from building products and furnishing Emiss
22、ion test cell method DIN EN ISO 16000-11, Determination of the emission of volatile organic compounds from building products and furnishing Sampling, storage of samples and preparation of test specimens DIN EN ISO 16000-12, Sampling strategy for polychlorinated biphenyls (PCBs), polychlorinated dibe
23、nzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and polycyclic aromatic hydrocarbons (PAHs) DIN ISO 16000-13, Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and polychlorinated dibenzo-p- dioxins/dibenzofurans (PCDDs/PCDFs) Collection on sor
24、bent-backed filters DIN ISO 16000-14, Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs) Extraction, clean-up and analysis by high-resolution gas chromatography/mass spectrometry DIN EN ISO 16
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DINISO16000272014INDOORAIRPART27DETERMINATIONOFSETTLEDFIBROUSDUSTONSURFACESBYSEMSCANNINGELECTRONMICROSCOPYDIRECTMETHODISO16000272014

链接地址:http://www.mydoc123.com/p-684170.html