1、BSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06Consideration on the use of OTDRs to measure return loss of single-mode optical fibre connectionsPD CLC/TR 50682:2018TECHNICAL REPORT RAPPORT TECHNIQUE TECHNISCHER BERICHT CLC/TR 50682 June 2018 ICS 33.180.01 English Ve
2、rsion Consideration on the use of OTDRs to measure return loss of single-mode optical fibre connections Examen de lutilisation de la rflectomtrie optique dans le domaine temporel (OTDR) pour la mesure de laffaiblissement de rflexion des connexions en unimodal berlegungen zur Verwendung von OTDRs zur
3、 Messung der Rckflussdmpfung von Einmoden-LWL-VerbindungenThis Technical Report was approved by CENELEC on 2018-04-16. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic
4、of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardiz
5、ation Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels 2018 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. CLC/TR 506
6、82:2018 ENational forewordThis Published Document is the UK implementation of CLC/TR 50682:2018.The UK participation in its preparation was entrusted to Technical Committee GEL/86/2, Fibre optic interconnecting devices and passive components.A list of organizations represented on this committee can
7、be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2018 Published by BSI Standards Limited 2018ISBN 978 0 580 51409 8ICS 33.180.01Complia
8、nce with a British Standard cannot confer immunity from legal obligations.This Published Document was published under the authority of the Standards Policy and Strategy Committee on 30 June 2018.Amendments/corrigenda issued since publicationDate Text affectedPUBLISHED DOCUMENTPD CLC/TR 50682:2018TEC
9、HNICAL REPORT RAPPORT TECHNIQUE TECHNISCHER BERICHT CLC/TR 50682 June 2018 ICS 33.180.01 English Version Consideration on the use of OTDRs to measure return loss of single-mode optical fibre connections Examen de lutilisation de la rflectomtrie optique dans le domaine temporel (OTDR) pour la mesure
10、de laffaiblissement de rflexion des connexions en unimodal berlegungen zur Verwendung von OTDRs zur Messung der Rckflussdmpfung von Einmoden-LWL-VerbindungenThis Technical Report was approved by CENELEC on 2018-04-16. CENELEC members are the national electrotechnical committees of Austria, Belgium,
11、Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Swe
12、den, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels 2018 CENELEC All rights of ex
13、ploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. CLC/TR 50682:2018 EPD CLC/TR 50682:2018CLC/TR 50682:2018 (E) 2 Contents Page European foreword . 3 Introduction . 4 1 Scope . 5 2 Normative references . 5 3 Terms and definitions 5 4 Description of Samples . 5 5
14、 Test 6 6 Test results . 6 7 Conclusions 12 Annex A (informative) Test data obtained in the Round Robin 13 Bibliography 19 PD CLC/TR 50682:2018CLC/TR 50682:2018 (E) 3 European foreword This document (CLC/TR 50682:2018) has been prepared by CLC/TC 86BXA “Fibre optic interconnect, passive and connecto
15、rised components“. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights. PD CLC/TR 50682:2018CLC/TR 50682:2018 (E) 4 Introduction The introduction of n
16、ew types of optical fibre (i.e. ITU-T G.657, EN 60793-2-50 B6 type) and the differences between manufacturers products cause a spread of up to 3 dB in the backscatter values (Bs) of available telecommunications single mode fibre. The variation in this parameter can lead to large differences in measu
17、red return loss (RL) of connections. This can give issues in field measurement where the fibre type and manufacturer may be unknown and the Bs may not be updated for each measurement in the OTDR. To evaluate the real impact of this spread of backscatter vales on return loss measurement, a Round Robi
18、n Test (RRT) was designed by CLC TC86BXA in 2015. “Black-box” connections (i.e. closed boxes with a connection of two plugs and fibre with similar or different Bs values) were circulated for testing in 2016 and 2017 around several laboratories. The result of this Round Robin is intended to contribut
19、e to future specification of return loss requirements on optical components. PD CLC/TR 50682:2018CLC/TR 50682:2018 (E) 5 1 Scope The purpose of this document is to describe a round robin on return loss of single mode optical fibre connections. This includes the description of the samples, the test p
20、rocedures and test instrumentation, results and conclusions. 2 Normative references The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated referen
21、ces, the latest edition of the referenced document (including any amendments) applies. EN 61300-3-6:2009, Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-6: Examinations and measurements - Return loss 3 Terms and definitions For the purpose
22、s of this document, the following terms and definitions apply. ISO and IEC maintain terminological databases for use in standardization at the following addresses: IEC Electropedia: available at http:/www.electropedia.org/ ISO Online browsing platform: available at http:/www.iso.org/obp 3.1 return l
23、oss RL ratio of the power (Pi) incident on, or entering, the DUT to the total power reflected (Pr) by the DUT, expressed in decibels 3.2 backscatter value Bsbackscattering level of the OTDR trace is a constant (K) that includes both the Rayleigh backscattering of the fibre and the OTDR pulse duratio
24、n 4 Description of Samples The Device Under Test (DUT) was an optical fibre-to-fibre connection, protected by a box, making the connection inaccessible to the user. The patch cords used in the DUTs were provided by different manufacturers to ensure a mix of fibres. The plugs in the connection were e
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CLCTR506822018CONSIDERATIONONTHEUSEOFOTDRSTOMEASURERETURNLOSSOFSINGLEMODEOPTICALFIBRECONNECTIONSPDF

链接地址:http://www.mydoc123.com/p-629543.html