1、Electromagnetic characteristics of linear cable management systems (CMS)PD CLC/TR 50659:2017BSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06National forewordThis Published Document is the UK implementation of CLC/TR 50659:2017. The UK participation in its preparation
2、 was entrusted to TechnicalCommittee PEL/213, Cable management.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions ofa contract. Users are responsible for its correct application. T
3、he British Standards Institution 2017.Published by BSI Standards Limited 2017ISBN 978 0 580 92142 1ICS 29.120.10Compliance with a British Standard cannot confer immunity fromlegal obligations.This Published Document was published under the authority of theStandards Policy and Strategy Committee on 3
4、1 March 2017.Amendments/corrigenda issued since publicationDate Text affectedPUBLISHED DOCUMENTPD CLC/TR 50659:2017TECHNICAL REPORT RAPPORT TECHNIQUE TECHNISCHER BERICHT CLC/TR 50659 March 2017 ICS 29.120.10 English Version Electromagnetic characteristics of linear cable management systems (CMS) Rap
5、port Technique - Caractristiques lectromagntiques des systmes linaires de cblage Elektromagnetische Eigenschaften von linearen Kabelfhrungssystemen This Technical Report was approved by CENELEC on 2017-03-06. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria,
6、 Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Swit
7、zerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2017 CENELEC All rights of exploitation in
8、 any form and by any means reserved worldwide for CENELEC Members. Ref. No. CLC/TR 50659:2017 E PD CLC/TR 50659:2017CLC/TR 50659:2017 (E) 2 Contents Page European foreword 3 1 Scope 4 2 Normative references 4 3 Terms and definitions 4 4 Shielding effectiveness of magnetic field . 5 5 Transfer impeda
9、nce . 16 Annex A (informative) Example of calculation of the reduction of distance required between parallel power cables and signal cables provided by a cable management system 24 Bibliography . 27 PD CLC/TR 50659:2017CLC/TR 50659:2017 (E) 3 European foreword This document (CLC/TR 50659:2017) has b
10、een prepared by CLC/TC 213, “Cable management systems”. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights. This Technical Report provides test metho
11、ds for the measurement of electromagnetic characteristics of linear Cable Management Systems (CMS). This is a European Technical Report for cable management products used for electro-technical purposes. It relates to the Council Directives on the approximation of laws, regulations and administrative
12、 provisions of the Member States relating to Low Voltage Directive 2014/35/EU through consideration of the essential requirements of this Directive. This European Technical Report is supported by separate standards to which references are made. PD CLC/TR 50659:2017CLC/TR 50659:2017 (E) 4 1 Scope Thi
13、s Technical Report provides test methods for the measurement of the following electromagnetic characteristics of lengthwise cable management systems like conduit systems according to EN 61386 series, cable trunking systems and cable ducting systems (CTS/CDS) according to EN 50085 series and cable tr
14、ay and cable ladder systems according to EN 61537: shielding effectiveness of magnetic field, transfer impedance. This Technical Report also provides guidance on how these characteristics can be declared and may be used. Powertrack systems covered by EN 61534 series are not covered by this edition o
15、f the Technical Report and may be considered in a new edition. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the
16、 latest edition of the referenced document (including any amendments) applies. EN 61000-4-5, Electromagnetic Compatibility (EMC) Part 4-5: Testing and measurement techniques Surge immunity test (IEC 61000-4-5) EN 61000-5-7, Electromagnetic compatibility (EMC) - Part 5-7: Installation and mitigation
17、guidelines - Degrees of protection by enclosures against electromagnetic disturbances (EM code) 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 shielding effectiveness SE ability of a cable management system to attenuate an electromagnetic si
18、gnal as it enters or exits the CMS, quantified as the ratio of a signal received (from a transmitter) without the shield, to the signal received with the shield in place 3.2 magnetic field constituent of an electromagnetic field which is characterized by the magnetic field strength H together with t
19、he magnetic flux density B Note 1 to entry: In French, the term “champ magntique” is also used for the quantity magnetic field strength. SOURCE: IEV 121-11-69 3.3 signal to noise ratio SNR ratio in dB between the measured peak current I1,max in the current loop when the current probe is connected to
20、 the current loop and the measured peak current IN,max when the current probe is not connected to the current loop but in a narrow position of the current loop. Both peak currents measured at the same excitation current in the excitation winding NISNR dBI= 120,max,max( ) log Note 1 to entry: I1,max
21、and IN,max show their maxima at different time. PD CLC/TR 50659:2017CLC/TR 50659:2017 (E) 5 3.4 electromagnetic shielding coding coding system to indicate the degree of protection provided by a CMS against the passage of electromagnetic energy 3.5 CMS transfer impedance ZCMSratio of a voltage drop,
22、between two specified points, caused by a disturbing current flowing through the cable management system and the disturbing current This voltage drop is a combination of the voltage drop along this cable management system due to the current flowing through this cable management system and the voltag
23、e drop along a conductor contained in this cable management system due to the magnetic field arising from the current flowing through this cable management system. 3.6 virtual CMS transfer impedance Zv CMSCMS transfer impedance defined by the ratio of the maximum asymmetrical mode voltage and the ma
24、ximum disturbing current during a time domain pulse 3.7 common mode voltage (or asymmetrical voltage VAS) mean of the phasor voltages appearing between each conductor and a specified reference, usually earth or frame SOURCE: IEV 161-04-09, modified 3.8 shielded enclosure (or screened room) mesh or s
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CLCTR506592017ELECTROMAGNETICCHARACTERISTICSOFLINEARCABLEMANAGEMENTSYSTEMSCMSPDF

链接地址:http://www.mydoc123.com/p-629540.html