CLC TR 50427-2004 Assessment of inadvertent ignition of flammable atmospheres by radio-frequency radiation C Guide《由射频辐射引起的易燃空气意外着火的评定 指南》.pdf
《CLC TR 50427-2004 Assessment of inadvertent ignition of flammable atmospheres by radio-frequency radiation C Guide《由射频辐射引起的易燃空气意外着火的评定 指南》.pdf》由会员分享,可在线阅读,更多相关《CLC TR 50427-2004 Assessment of inadvertent ignition of flammable atmospheres by radio-frequency radiation C Guide《由射频辐射引起的易燃空气意外着火的评定 指南》.pdf(98页珍藏版)》请在麦多课文档分享上搜索。
1、PUBLISHED DOCUMENTPD CLC/TR 50427:2004Assessment of inadvertent ignition of flammable atmospheres by radio-frequency radiation Guide ICS 13.230; 33.060.20g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55
2、g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58PD CLC/TR 50427:2004This Published Document was published under the authority of the Standards Policy and Strategy Committee on 28 April 2006 BSI 2006ISBN 0 580 45883 0National forewordThis Published Document is the official English language vers
3、ion of CLC/TR 50427:2004. It is envisaged that PD CLC/TR 50427:2004 will eventually replace BS 6656:2002 but for a transitional period both documents will be current in order for users of the standards to familiarize themselves with the contents of the new document.The UK participation in its prepar
4、ation was entrusted by Technical Committee GEL/31, Electrical apparatus for explosive atmospheres, to Subcommittee GEL/31/-/602, Radio-frequency radiation-induced ignition and detonation, which has the responsibility to:A list of organizations represented on this subcommittee can be obtained on requ
5、est to its secretary.Cross-referencesThe British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogueunder the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Elec
6、tronic Catalogue or of British Standards Online.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a Published Document does not of itself confer immunity from legal obligations. aid enquirers to
7、understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK.Summary of pagesThis document compr
8、ises a front cover, an inside front cover, the CLC/TR title page, pages 2 to 95 and a back cover.The BSI copyright notice displayed in this document indicates when the document was last issued.Amendments issued since publicationAmd. No. Date CommentsTECHNICAL REPORT CLC/TR 50427RAPPORT TECHNIQUE TEC
9、HNISCHER BERICHT December 2004 CENELECEuropean Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels ICS 13.230; 33.060.20 English version Assessment o
10、f inadvertent ignition of flammable atmospheresby radio-frequency radiation GuideEvaluation des risques dinflammation des atmosphres inflammablespar des rayonnements de radiofrquence GuideLeitfaden zur Verhinderungder unbeabsichtigten Zndung explosionsfhiger Atmosphrendurch hochfrequente Strahlung T
11、his Technical Report was approved by CENELEC on 2004-08-28. CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,Latvia, Lithuania, Luxembourg, Malta, Netherlands
12、, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. 2004 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. CLC/TR 50427:2004 E PD CLC/TR 50427:2004 2 Foreword This Technical Report was prepare
13、d by the Technical Committee CENELEC TC 31, Electrical apparatus for explosive atmospheres - General requirements. The text of the draft was submitted to the formal vote and was approved by CENELEC as CLC/TR 50427 on 2004-08-28. _ 3 PD CLC/TR 50427:2004ContentsIntroduction 6 1 Scope72 Normative refe
14、rences .73 Terms and definitions.74 Symbols and abbreviations .94.1 Modulation codes94.2 Polarization codes.105 General considerations 105.1 Radio-frequency hazard105.2 Philosophy of systematic method of approach .11 5.3 Responsibility for making the hazard assessment116 Transmitters and transmitter
15、 output parameters 126.1 Types of transmitter 126.2 Frequency range.126.3 Transmitter output power126.4 Antenna gain.126.5 Modulation factors.126.5.1 General.126.5.2 Frequency modulation (FM).136.5.3 Amplitude modulation (AM)136.5.4 Single sideband (SSB) operation.136.5.5 Pulsed radar.137 Structures
16、 and spark-making mechanisms .147.1 Structures147.2 Loop-type structures .147.3 Vertical structures .167.4 Spark-making mechanisms.178 Ignition of flammable atmospheres.178.1 Flammable atmospheres 178.2 Ignition by radio-frequency discharges .178.3 Criteria for ignition.188.3.1 Effectively continuou
17、s transmissions .188.3.2 Radar transmissions 189 Practical measurements and tests199.1 Measurement of electromagnetic fields 199.2 Measurement of extractable power 199.3 Test transmissions 209.4 Incendivity tests 20PD CLC/TR 50427:2004 4 10 Methods of assessment for determining potential RF ignition
18、 hazards on a plantcontaining hazardous areas.2110.1 General .21 10.2 Basis of the theoretical assessments .2110.2.1 General.21 10.2.2 Initial assessment.22 10.2.3 Full assessment .2210.3 Initial assessments32 10.3.1 Initial assessment of the risk from a particular transmitter site32 10.3.2 Initial
19、assessment for a particular plant33 10.4 Full assessment procedure.34 10.4.1 Procedure.34 10.4.2 Information to be obtained .35 10.4.3 Calculation of effective field strengths .35 10.4.4 Calculation of extractable power or energy41 10.4.5 Comparison of the total extractable power or energy from the
20、structure with the threshold values detailed in Clause 8 43 10.5 Practical on-site tests46 10.5.1 Procedure.46 10.5.2 Plant and transmitter both in existence (Case 1 of Figure 3).46 10.5.3 Existing plant and proposed transmitter (Case 2 of Figure 3) .47 10.5.4 Existing transmitter and proposed plant
21、 (Case 3 of Figure 3) .48 11 Plant safety measures 49 11.1 General .49 11.2 Bonding.49 11.3 Insulation.50 11.4 Reducing the structure efficiency50 11.5 De-tuning of structures50 12 Special cases.51 12.1 Cranes.51 12.2 Mobile and portable transmitters.51 12.3 Ships .51 12.3.1 General.51 12.3.2 Ships
22、in harbour areas.52 12.3.3 Ships at sea .52 12.4 Offshore oil and gas installations53 12.4.1 General.53 12.4.2 Structures on offshore installations53 12.4.3 Assessment procedures.53 12.4.4 Radio frequency transmitters and vulnerable zones54 12.4.5 Safety measures and recommendation .55 5 PD CLC/TR 5
23、0427:2004Annex A (informative) Sources of information and addresses of some advisory bodies.57Annex B (informative) Electromagnetic radiated fields and examples of radiating antenna andunintended receiving antenna characteristics 59Annex C (informative) Subdivision of group II flammable gases and va
24、pours.67Annex D (normative) Measurement of electromagnetic fields .72Annex E (normative) Methods of measurement on structures (on-site tests)76Annex F (informative) Derivation of vulnerable zone distances for Table 5, Table 6 and Table 10 82Annex G (informative) Worked examples of full assessment pr
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CLCTR504272004ASSESSMENTOFINADVERTENTIGNITIONOFFLAMMABLEATMOSPHERESBYRADIOFREQUENCYRADIATIONCGUIDE 射频

链接地址:http://www.mydoc123.com/p-629493.html