CLC TR 50378-2-2-2008 Passive components to be used in optical fibre communication systems - Product specifications - Part 2-2 SC(SC2)-APC connector-type fixed optical attenuators .pdf
《CLC TR 50378-2-2-2008 Passive components to be used in optical fibre communication systems - Product specifications - Part 2-2 SC(SC2)-APC connector-type fixed optical attenuators .pdf》由会员分享,可在线阅读,更多相关《CLC TR 50378-2-2-2008 Passive components to be used in optical fibre communication systems - Product specifications - Part 2-2 SC(SC2)-APC connector-type fixed optical attenuators .pdf(28页珍藏版)》请在麦多课文档分享上搜索。
1、PUBLISHED DOCUMENTPD CLC/TR 50378-2-2:2008Passive components to be used in optical fibre communication systems Product specifications Part 2-2: SC(SC2)-APC connector-type fixed optical attenuators using IEC 60793-2 Category B1.1 singlemode fibreICS 33.180.20g49g50g3g38g50g51g60g44g49g42g3g58g44g55g4
2、3g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58PD CLC/TR 50378-2-2:2008This Published Document was published under the authority of the Standards Policy and Strategy Committee on 30 May 200
3、8 BSI 2008ISBN 978 0 580 62889 4National forewordThis Published Document is the UK implementation of CLC/TR 50378-2-2:2008.The UK participation in its preparation was entrusted by Technical Committee GEL/86, Fibre optics, to Subcommittee GEL/86/2, Fibre optic interconnecting devices and passive comp
4、onents.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Amendments/corrigenda issued since publicationDate Comme
5、ntsTECHNICAL REPORT CLC/TR 50378-2-2 RAPPORT TECHNIQUE TECHNISCHER BERICHT April 2008 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Bru
6、ssels 2008 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. CLC/TR 50378-2-2:2008 E ICS 33.180.20 English version Passive components to be used in optical fibre communication systems - Product specifications - Part 2-2: SC(SC2)-APC co
7、nnector-type fixed optical attenuators using IEC 60793-2 Category B1.1 singlemode fibre This Technical Report was approved by CENELEC on 2008-01-10. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Fran
8、ce, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Foreword This Technical Report was prepared by the Technical Committee CENELEC TC 86
9、BXA, Fibre optic interconnect, passive and connectorised components. The text of the draft was submitted to the vote and was approved by CENELEC as CLC/TR 50378-2-2 on 2008-01-10. _ CLC/TR 50378-2-2:2008 2 Passive components to be used in optical fibre communication systems Product specifications Pa
10、rt 2-2: SC(SC2)-APC connector-type fixed optical attenuators using IEC 60793-2 Category B1.1 singlemode fibre Description Performance Type: fixed Application: EN 61753-1:2007 Category UETSI ES 201 286 Style: plug style Operating wavelength: (1 260 1 360) nm and (1 460 1 625) nm Attenuation: 1 dB, 5
11、dB, and 15 dB Coupling mechanism: push pull Configuration: plug-attenuator-adaptor-plugFibre category: special fibres Return loss grades: V: 60 dB References: EN 50377-4-2 1)Connector sets and interconnect components to be used in optical fibre communication systems Product specifications Part 4-2:
12、Type SC-APC simplex 8 and 9 degree terminated on IEC 60793-2 category B1.1 singlemode fibre EN 60793-2 Optical fibres Part 2: Product specifications General (IEC 60793-2) EN 61300 series Fibre optic interconnecting devices and passive components Basic test and measurement procedures (IEC 61300 serie
13、s) EN 61753-1 Fibre optic interconnecting devices and passive components performance standard Part 1: General and guidance for performance standards (IEC 61753-1:2007) EN 61753-051-3 Fibre optic interconnecting devices and passive components performance standard Part 051-3: Single-mode fibre, plug-s
14、tyle fixed attenuators for category U - Uncontrolled environment (IEC 61753-051-3) ETSI ES 201 286 Transmission and Multiplexing (TM); Passive optical components; Connector-type optical fixed attenuators for single-mode optical fibre communications systems; Common requirements and conformance testin
15、g ETSI EN 300 019 (series) Equipment Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment Outline and maximum dimensions: 1)At draft stage. CLC/TR 50378-2-2:2008 3 Contents 1 Scope 5 2 Test samples 5 3 Test program 5 3.1 Spectral attenuation loss (accor
16、ding to EN 61300-3-5) 5 3.2 Attenuation at 1 310 nm and 1 550 nm measured with LED source and power meter 5 3.3 Polarisation dependent loss (PDL) (according to EN 61300-3-2 method 1) 5 4 Test laboratories involved in this RRT 5 5 Measurement results 6 5.1 Individual test laboratory results with refe
17、rence connectors . 6 5.2 Overview of all attenuation test results . 15 5.3 Summary of attenuation measurements results 21 5.4 Overview of PDL results . 24 6 Mechanical interface issues with SC/APC plug style attenuators . 24 7 Conclusions 25 Table 1 PDL measurements from Laboratory A . 7 Table 2 PDL
18、 measurements from Laboratory B . 9 Table 3 PDL measurements from Laboratory C . 10 Table 4 PDL measurements from Laboratory D . 12 Table 5 PDL measurements from Laboratory E . 14 Table 6 Pass/fail result . 21 Table 7 Pass/fail result with relaxed performance critera . 21 Table 8 Pass/fail result .
19、22 Table 9 Pass/fail result with relaxed performance critera . 22 Table 10 LED measurements results at 1 310 nm (green colour = pass) 23 Table 11 LED measurements results at 1 550 nm (green colour = pass) 23 Table 12 SC/APC plug style attenuator behaviour analysis for different working configuration
20、s . 25 Figure 1 Laboratory A results Spectral measurements 6 Figure 2 Laboratory A results LED measurements 7 Figure 3 Laboratory B results Spectral measurements 8 Figure 4 Laboratory B results LED measurements 8 Figure 5 Laboratory C results Spectral measurements 9 Figure 6 Laboratory C results LED
21、 measurements 10 Figure 7 Laboratory D results Spectral measurements 11 Figure 8 Laboratory D results LED measurements 12 Figure 9 Laboratory E results Spectral measurements 13 Figure 10 Laboratory E results LED measurements 14 Figure 11 1 dB attenuators All laboratories results Common reference . 1
22、5 Figure 12 5 dB attenuators All laboratories results Common reference . 17 Figure 13 15 dB attenuators All laboratories results Common reference . 19 Figure 14 Overview of PDL measurements results 24 CLC/TR 50378-2-2:2008 4 1 Scope This document reports the measurement results of a round robin test
23、 program carried out on SC/APC plug style fixed attenuators. The work was initiated at CENELEC CLC/TC 86BXA in November 2004 in order to get a clear understanding on the accuracy and repeatability of the spectral attenuation loss measurements on fixed attenuators. Out of these results some recommend
24、ations are made for attenuation tolerance values that can be used in the performance standards. 2 Test samples In total 18 SC/APC plug style fixed attenuators were collected for this round robin test: 6 attenuators with nominal attenuation of 1 dB (labelled 1, 2, 3, 4, 5, 6); 6 attenuators with nomi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CLCTR50378222008PASSIVECOMPONENTSTOBEUSEDINOPTICALFIBRECOMMUNICATIONSYSTEMSPRODUCTSPECIFICATIONSPART22SCSC2APCCONNECTORTYPEFIXEDOPTICALATTENUATORSPDF

链接地址:http://www.mydoc123.com/p-629489.html