CLC TR 50117-8-2013 Coaxial cables used in cabled distribution networks - Part 8 Repair and substitute of damaged buried cables.pdf
《CLC TR 50117-8-2013 Coaxial cables used in cabled distribution networks - Part 8 Repair and substitute of damaged buried cables.pdf》由会员分享,可在线阅读,更多相关《CLC TR 50117-8-2013 Coaxial cables used in cabled distribution networks - Part 8 Repair and substitute of damaged buried cables.pdf(28页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationCoaxial cables used in cabled distribution networksPart 8: Repair and substitute of damaged buried cablesPD CLC/TR 50117-8:2013National forewordThis Published Document is the UK
2、implementation of CLC/TR 50117-8:2013.The UK participation in its preparation was entrusted to Technical CommitteeEPL/46, Cables, wires and waveguides, radio frequency connectors and accessories for communication and signalling.A list of organizations represented on this committee can be obtained on
3、request to its secretary.This publication does not purport to include all the necessary provisions of acontract. Users are responsible for its correct application. The British Standards Institution 2013Published by BSI Standards Limited 2013ISBN 978 0 580 80756 5ICS 33.120.10Compliance with a Britis
4、h Standard cannot confer immunity fromlegal obligations.This Published Document was published under the authority of theStandards Policy and Strategy Committee on 30 April 2013.Amendments issued since publicationAmd. No. Date Text affectedPUBLISHED DOCUMENTPD CLC/TR 50117-8:2013TECHNICAL REPORT CLC/
5、TR 50117-8 RAPPORT TECHNIQUE TECHNISCHER BERICHT March 2013 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2013 CENELEC - All right
6、s of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. CLC/TR 50117-8:2013 E ICS 33.120.10 English version Coaxial cables used in cabled distribution networks - Part 8: Repair and substitute of damaged buried cables Cbles coaxiaux pour rseaux cbls de distribu
7、tion - Partie 8: Rparation et remplacement de cbles coaxiaux souterrain Koaxialkabel fr Kabelverteilanlagen - Teil 8: Reparatur und Ersatz beschdigter Koaxialkabel This Technical Report was approved by CENELEC on 2013-02-26. CENELEC members are the national electrotechnical committees of Austria, Be
8、lgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Swed
9、en, Switzerland, Turkey and the United Kingdom. PD CLC/TR 50117-8:2013CLC/TR 50117-8:2013 2 Contents Page Foreword . 4 1 Scope . 5 2 Normative References . 5 3 Terms and definitions 6 4 Coaxial cables 6 4.1 Construction of coaxial cables . 6 4.2 Long term behaviour and asset of coaxial underground c
10、ables . 6 5 Laying of underground cables 6 5.1 General 6 5.2 Laying in the sand bed . 7 5.3 Laying in ducts 7 5.4 Laying in a duct system 7 5.5 Laying in the conduit 7 6 Effects of damage . 7 6.1 General 7 6.2 Repair 7 6.3 Influence to electric characteristics 8 7 Types of errors . 9 7.1 General 9 7
11、.2 Transection without stretching (shearing, cutting) 9 7.3 Disruption / cable elongation with impact on indefinite length 9 7.4 Strain / elongation without tearing effect with an indefinite length of cable. 9 7.5 Other damage with selective or limited local impact . 9 7.5.1 General 9 7.5.2 Deformat
12、ion without stretching, such as squeezing, compressing, dropping below the minimum bending radius 9 7.5.3 Damage to the outer sheath by fire or heat . 9 7.5.4 Slightly damaged cable sheath without deformation of the outer conductors . 10 8 Failure analysis and repair . 10 8.1 General 10 8.2 Fundamen
13、tal distinction of occurring damage and its repair 10 8.2.1 General 10 8.2.2 Cable was not elongated 11 8.2.4 Cable was deformed 11 8.2.5 Jacket was damaged . 11 8.2.6 Outer conductor has transverse cracks 11 8.2.7 Screening effectiveness otherwise affected . 12 8.2.8 Inner conductor looks out from
14、the cable ends 12 8.2.9 Diameter of inner and outer conductor within the specified limits . 12 8.2.10 Effects of tensile forces to remote components 12 8.2.11 Measures for damaged cables with 60 - Ohm impedance . 12 8.2.12 Repairs due to other influences . 12 9 Attenuation of cable joints and connec
15、tors . 12 PD CLC/TR 50117-8:2013 3 CLC/TR 50117-8:2013 10 Use of materials and correct handling . 13 10.1 General 13 10.2 Proper processing . 13 11 Documentation . 14 12 Measurement evidence . 14 12.1 Measuring of power levels 14 12.2 Measuring of reflexion 14 12.3 Measuring of radiated power . 14 1
16、2.4 Measuring of Bit Error Rate (BER) . 14 Annex A (informative) Theoretical Background . 15 A.1 Physical background and Characteristics / parameters for coaxial cable 15 A.2 Reflection coefficient 16 A.3 Return loss . 16 A.4 Pulse return loss . 17 Annex B (informative) Examples of damage . 19 Bibli
17、ography . 23 Figure 1 Construction of a coaxial cable . 6 Figure A.1 Coaxial cables . 15 Figure A.2 Schematic depiction for measuring the return loss . 17 Figure A.3 Composition of the test device for measuring the pulse reflection 18 Figure B.1 Typical damage by laying new paths across the cable pa
18、th . 19 Figure B.2 Underground cable repair of a selectively damaged cable without elongation . 19 Figure B.3 Effect of tensile forces: building entry pulled out of the brickwork, the basement conduit installation ripped out of wall 20 Figure B.4 Selectively damaged cable: sheath peeled off . 20 Fig
19、ure B.5 Cable cut by blade 20 Figure B.6 Torn underground cables . 21 Figure B.7 Damaged cable by tension forces, inner conductor torned. 21 Figure B.8 Perforated screening by pulling forces: Screening effectiveness drastically reduced 21 Figure B.9 Inside of the perforated screening foil by elongat
20、ion of the coaxial cable shielding . 22 PD CLC/TR 50117-8:2013CLC/TR 50117-8:2013 4 Foreword This document (CLC/TR 50117-8:2013) has been prepared by CLC/SC 46XA “Coaxial cables“. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CE
21、NELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. EN 50117 is divided into the following parts: EN 50117-1, Coaxial cables Part 1: Generic specification EN 50117-2-1, Coaxial cables Part 2-1: Sectional specification for cables used in cabled distribution n
22、etworks Indoor drop cables for systems operating at 5 MHz - 1 000 MHz EN 50117-2-2, Coaxial cables Part 2-2: Sectional specification for cables used in cabled distribution networks Outdoor drop cables for systems operating at 5 MHz - 1 000 MHz EN 50117-2-3, Coaxial cables Part 2-3: Sectional specifi
23、cation for cables used in cabled distribution networks Distribution and trunk cables for systems operating at 5 MHz - 1 000 MHz EN 50117-2-4, Coaxial cables Part 2-4: Sectional specification for cables used in cabled distribution networks Indoor drop cables for systems operating at 5 MHz - 3 000 MHz
24、 EN 50117-2-5, Coaxial cables Part 2-5: Sectional specification for cables used in cabled distribution networks Outdoor drop cables for systems operating at 5 MHz - 3 000 MHz EN 50117-3-1, Coaxial cables Part 3-1: Sectional specifications for cables used in Telecom applications Miniaturized cables u
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CLCTR5011782013COAXIALCABLESUSEDINCABLEDDISTRIBUTIONNETWORKSPART8REPAIRANDSUBSTITUTEOFDAMAGEDBURIEDCABLESPDF

链接地址:http://www.mydoc123.com/p-629481.html