CSA Z259 11-2005 Energy absorbers and lanyards (Second Edition Update No 1 October 2007).pdf
《CSA Z259 11-2005 Energy absorbers and lanyards (Second Edition Update No 1 October 2007).pdf》由会员分享,可在线阅读,更多相关《CSA Z259 11-2005 Energy absorbers and lanyards (Second Edition Update No 1 October 2007).pdf(46页珍藏版)》请在麦多课文档分享上搜索。
1、Z259.11-05(reaffirmed 2015)Energy absorbers and lanyardsLegal Notice for StandardsCanadian Standards Association (CSA) standards are developed through a consensus standards development process approved by the Standards Council of Canada. This process brings together volunteers representing varied vi
2、ewpoints and interests to achieve consensus and develop a standard. Although CSA administers the process and establishes rules to promote fairness in achieving consensus, it does not independently test, evaluate, or verify the content of standards.Disclaimer and exclusion of liabilityThis document i
3、s provided without any representations, warranties, or conditions of any kind, express or implied, including, without limitation, implied warranties or conditions concerning this documents fitness for a particular purpose or use, its merchantability, or its non-infringement of any third partys intel
4、lectual property rights. CSA does not warrant the accuracy, completeness, or currency of any of the information published in this document. CSA makes no representations or warranties regarding this documents compliance with any applicable statute, rule, or regulation. IN NO EVENT SHALL CSA, ITS VOLU
5、NTEERS, MEMBERS, SUBSIDIARIES, OR AFFILIATED COMPANIES, OR THEIR EMPLOYEES, DIRECTORS, OR OFFICERS, BE LIABLE FOR ANY DIRECT, INDIRECT, OR INCIDENTAL DAMAGES, INJURY, LOSS, COSTS, OR EXPENSES, HOWSOEVER CAUSED, INCLUDING BUT NOT LIMITED TO SPECIAL OR CONSEQUENTIAL DAMAGES, LOST REVENUE, BUSINESS INT
6、ERRUPTION, LOST OR DAMAGED DATA, OR ANY OTHER COMMERCIAL OR ECONOMIC LOSS, WHETHER BASED IN CONTRACT, TORT (INCLUDING NEGLIGENCE), OR ANY OTHER THEORY OF LIABILITY, ARISING OUT OF OR RESULTING FROM ACCESS TO OR POSSESSION OR USE OF THIS DOCUMENT, EVEN IF CSA HAS BEEN ADVISED OF THE POSSIBILITY OF SU
7、CH DAMAGES, INJURY, LOSS, COSTS, OR EXPENSES.In publishing and making this document available, CSA is not undertaking to render professional or other services for or on behalf of any person or entity or to perform any duty owed by any person or entity to another person or entity. The information in
8、this document is directed to those who have the appropriate degree of experience to use and apply its contents, and CSA accepts no responsibility whatsoever arising in any way from any and all use of or reliance on the information contained in this document. CSA is a private not-for-profit company t
9、hat publishes voluntary standards and related documents. CSA has no power, nor does it undertake, to enforce compliance with the contents of the standards or other documents it publishes. Intellectual property rights and ownershipAs between CSA and the users of this document (whether it be in printe
10、d or electronic form), CSA is the owner of all works contained herein that are protected by copyright, all trade-marks (except as otherwise noted to the contrary), and all inventions and trade secrets that may be contained in this document, whether or not such inventions and trade secrets are protec
11、ted by patents and applications for patents. The unauthorized use, modification, copying, or disclosure of this document may violate laws that protect CSAs intellectual property and may give rise to a right in CSA to seek legal redress for such use, modification, copying, or disclosure. CSA reserves
12、 all intellectual property rights in this document.Authorized use of this documentThis document is being provided by CSA for informational and non-commercial use only. The user of this document is authorized to do only the following:If this document is in electronic form:.load this document onto a c
13、omputer for the sole purpose of reviewing it;.search and browse this document; and.print this document. Limited copies of this document in print or paper form may be distributed only to persons who are authorized by CSA to have such copies, and only if this Legal Notice appears on each such copy.In
14、addition, users may not and may not permit others to.alter this document in any way or remove this Legal Notice from the attached standard;.sell this document without authorization from CSA; or.make an electronic copy of this document.If you do not agree with any of the terms and conditions containe
15、d in this Legal Notice, you may not load or use this document or make any copies of the contents hereof, and if you do make such copies, you are required to destroy them immediately. Use of this document constitutes your acceptance of the terms and conditions of this Legal Notice.Update No. 1Z259.11
16、-05October 2007Note: General Instructions for CSA Standards are now called Updates. Please contact CSA Information Products Sales or visit www.ShopCSA.ca for information about the CSA Standards Update Service.Title: Energy absorbers and lanyards originally published February 2005The following revisi
17、ons have been formally approved and are marked by the symbol delta () in the margin on the attached replacement pages:Revised Clause 6.1.3.1New NoneDeleted NoneCSA Z259.11-05 originally consisted of 33 pages (x preliminary and 23 text), each dated February 2005. It now consists of the following page
18、s:February 2005 iiix, 114, and 1723October 2007 15 and 16 Update your copy by inserting these revised pages.Keep the pages you remove for reference. Canadian Standards Association Energy absorbers and lanyardsOctober 2007Figure 8Frequency response characteristics for the force-measuring instrumentat
19、ion when testing personal fall arrest systems(See Clause 6.1.1.4.)6.1.1.5 Drop test structure6.1.1.5.1 Natural frequencyThe natural frequency of the drop test structure measured along the vertical axis of the point of anchorage of the tested system shall be at least 200 Hz.6.1.1.5.2 Elastic deformat
20、ionThe maximum elastic deformation of the test structure at the point of anchorage of the tested system shall be 1.0 mm (0.04 in) for a 20.0 kN (4500 lbf) load applied in the intended direction of loading.Legend: a = 1/4 dBb = + 1/2 dB, 1 dBc = + 1/2 dB, 3 dBd = 9 dB/octavee = 24 dB/octavefH= 60 Hzf
21、L= 0.1 HzfN= 100 Hzg = 30 dBgbcde1001020304050afffL H NLog frequency (Hz)Output/input ratio (dB)15(Replaces p. 15, February 2005)Z259.11-05 Canadian Standards AssociationOctober 20076.1.1.6 Wire-rope test linkA wire-rope test link equipped with thimble eyes and splices secured with mechanical sleeve
22、s shall be provided for the energy absorber tests. The test link shall be fabricated from Type 302 stainless steel in a 9.5 mm (0.37 in) diameter, 7 19 aircraft-cable construction. Its length shall be capable of introducing a 1.8 m (5.9 ft) free drop.6.1.2 Dynamic drop test6.1.2.1 The test mass spec
23、ified in Clause 6.1.1.1 shall be suspended from a hoist through a quick-release mechanism (see Figure 9). The load cell shall be attached to an eyebolt on the drop test structure. One end of the energy absorber to be tested shall be attached to the load cell, and the other end shall be attached to t
24、he test mass. If the energy absorber has a total length of less than 1 m (3.3 ft), a wire-rope test link (see Clause 6.1.1.6) shall be employed to achieve the required drop distance.6.1.2.2 The test mass shall be lowered until the energy absorber is at full tension. The following information shall b
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CSAZ259112005ENERGYABSORBERSANDLANYARDSSECONDEDITIONUPDATENO1OCTOBER2007PDF

链接地址:http://www.mydoc123.com/p-621688.html