1、Z107.6-M90(reaffirmed 2014)Pure tone air conduction threshold audiometry for hearing conservationLegal Notice for StandardsCanadian Standards Association (operating as “CSA Group”) develops standards through a consensus standards development process approved by the Standards Council of Canada. This
2、process brings together volunteers representing varied viewpoints and interests to achieve consensus and develop a standard. Although CSA Group administers the process and establishes rules to promote fairness in achieving consensus, it does not independently test, evaluate, or verify the content of
3、 standards.Disclaimer and exclusion of liabilityThis document is provided without any representations, warranties, or conditions of any kind, express or implied, including, without limitation, implied warranties or conditions concerning this documents fitness for a particular purpose or use, its mer
4、chantability, or its non-infringement of any third partys intellectual property rights. CSA Group does not warrant the accuracy, completeness, or currency of any of the information published in this document. CSA Group makes no representations or warranties regarding this documents compliance with a
5、ny applicable statute, rule, or regulation. IN NO EVENT SHALL CSA GROUP, ITS VOLUNTEERS, MEMBERS, SUBSIDIARIES, OR AFFILIATED COMPANIES, OR THEIR EMPLOYEES, DIRECTORS, OR OFFICERS, BE LIABLE FOR ANY DIRECT, INDIRECT, OR INCIDENTAL DAMAGES, INJURY, LOSS, COSTS, OR EXPENSES, HOWSOEVER CAUSED, INCLUDIN
6、G BUT NOT LIMITED TO SPECIAL OR CONSEQUENTIAL DAMAGES, LOST REVENUE, BUSINESS INTERRUPTION, LOST OR DAMAGED DATA, OR ANY OTHER COMMERCIAL OR ECONOMIC LOSS, WHETHER BASED IN CONTRACT, TORT (INCLUDING NEGLIGENCE), OR ANY OTHER THEORY OF LIABILITY, ARISING OUT OF OR RESULTING FROM ACCESS TO OR POSSESSI
7、ON OR USE OF THIS DOCUMENT, EVEN IF CSA GROUP HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES, INJURY, LOSS, COSTS, OR EXPENSES.In publishing and making this document available, CSA Group is not undertaking to render professional or other services for or on behalf of any person or entity or to p
8、erform any duty owed by any person or entity to another person or entity. The information in this document is directed to those who have the appropriate degree of experience to use and apply its contents, and CSA Group accepts no responsibility whatsoever arising in any way from any and all use of o
9、r reliance on the information contained in this document. CSA Group is a private not-for-profit company that publishes voluntary standards and related documents. CSA Group has no power, nor does it undertake, to enforce compliance with the contents of the standards or other documents it publishes. I
10、ntellectual property rights and ownershipAs between CSA Group and the users of this document (whether it be in printed or electronic form), CSA Group is the owner, or the authorized licensee, of all works contained herein that are protected by copyright, all trade-marks (except as otherwise noted to
11、 the contrary), and all inventions and trade secrets that may be contained in this document, whether or not such inventions and trade secrets are protected by patents and applications for patents. Without limitation, the unauthorized use, modification, copying, or disclosure of this document may vio
12、late laws that protect CSA Groups and/or others intellectual property and may give rise to a right in CSA Group and/or others to seek legal redress for such use, modification, copying, or disclosure. To the extent permitted by licence or by law, CSA Group reserves all intellectual property rights in
13、 this document.Patent rightsAttention is drawn to the possibility that some of the elements of this standard may be the subject of patent rights. CSA Group shall not be held responsible for identifying any or all such patent rights. Users of this standard are expressly advised that determination of
14、the validity of any such patent rights is entirely their own responsibility.Authorized use of this documentThis document is being provided by CSA Group for informational and non-commercial use only. The user of this document is authorized to do only the following:If this document is in electronic fo
15、rm:sLOADTHISDOCUMENTONTOACOMPUTERFORTHESOLEPURPOSEOFREVIEWINGITsSEARCHANDBROWSETHISDOCUMENTANDsPRINTTHISDOCUMENTIFITISIN0$ (b) field condition; and (c) be phrased where possible to permit a specific rryesIt or rrnr answer. subscription details and a free sample copy, write to CSA Marketing or teleph
16、one (416) 747-4029. Use of the masculine gender in this Standard is not meant to Although the intended primary application of this Standard is Requests for interpretation should provide an explanation of circumstances surrounding the actual Interpretations are published in CSA Information Update. Fo
17、r CAN/CSA-Z107.6-M90 - January 1990 - Page 7 CAN/CSA-Z107.6-M90 - January 1990 - Page 8 CAN/CSA-Z107.6-M90 Pure Tone Air Conduction Threshold Audiometry for Hearing Conservation 1, Scope 1.1 This Standard specifies procedures and requirements for Pure Tone Air Conduction Threshold Audiometry, withou
18、t masking, used in hearing conservation programs. It is especially applicable to individuals whose hearing sensitivity might be adversely affected by occupational noise exposure. are to be used to identify individuals who are at risk through exposure to excessively high noise levels. The procedures
19、in this Standard 1.2 The Standard specifies test techniques for automatic recording, manual and computer controlled audiometry. 1-3 The procedures in this Standard are less stringent than those required for clinical use. 1.4 The user of this Standard should be proficient in audiometric test techniqu
20、es. 2. Definitions 2.1 In addition to definitions found in CSA Standards 2107.0 and 2107.4 the following definitions apply in this Standard. Air conduction-transmission of sound from the external and middle ear to the inner ear. Ascending test method-the presentation of consecutive test tones of asc
21、ending intensity to determine hearing threshold levels. Bracketing test method-the presentation of consecutive test tones of both ascending and descending intensity to determine hearing threshold levels. Audiogram-presentation, in graphic or tabular form, of the hearing threshold levels of the subje
22、cts ears, determined under specified conditions and by a specified method, as a function of frequency. Audiometers-standards for audiometers are presented in CSA Standard 2107.4-M86 (Pure Tone Audiometer). Hearing level at a specified frequency for a specific type of CAN/CSA-Z107.6-M90 - January 199
23、0 - Page 9 earphone and for a specified manner of application-the sound pressure level of this signal set up by the earphone in the acoustic coupler minus the appropriate standard reference threshold level. Hearing threshold level at a specified frequency-the difference in decibels between the heari
24、ng level of a subjects threshold of audibility and the standard reference threshold level. Threshold of audibility is the lowest level at which the subject can detect the presence of the stimulus for at least 50% of stimulus presentations. Otologically normal person-a person in a normal state of hea
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CSAZ1076M901990PURETONEAIRCONDUCTIONTHRESHOLDAUDIOMETRYFORHEARINGCONSERVATIONFIRSTEDITIONPDF

链接地址:http://www.mydoc123.com/p-621663.html