CSA C22 2 NO 183 1-M1982-1982 Alternating-Current (AC) Electrical Installations on Boats (First Edition).pdf
《CSA C22 2 NO 183 1-M1982-1982 Alternating-Current (AC) Electrical Installations on Boats (First Edition).pdf》由会员分享,可在线阅读,更多相关《CSA C22 2 NO 183 1-M1982-1982 Alternating-Current (AC) Electrical Installations on Boats (First Edition).pdf(32页珍藏版)》请在麦多课文档分享上搜索。
1、C22.2 No. 183.1-M1982(reaffirmed 2013)Alternating-current (AC) electrical installations on boatsLegal Notice for StandardsCanadian Standards Association (operating as “CSA Group”) develops standards through a consensus standards development process approved by the Standards Council of Canada. This p
2、rocess brings together volunteers representing varied viewpoints and interests to achieve consensus and develop a standard. Although CSA Group administers the process and establishes rules to promote fairness in achieving consensus, it does not independently test, evaluate, or verify the content of
3、standards.Disclaimer and exclusion of liabilityThis document is provided without any representations, warranties, or conditions of any kind, express or implied, including, without limitation, implied warranties or conditions concerning this documents fitness for a particular purpose or use, its merc
4、hantability, or its non-infringement of any third partys intellectual property rights. CSA Group does not warrant the accuracy, completeness, or currency of any of the information published in this document. CSA Group makes no representations or warranties regarding this documents compliance with an
5、y applicable statute, rule, or regulation. IN NO EVENT SHALL CSA GROUP, ITS VOLUNTEERS, MEMBERS, SUBSIDIARIES, OR AFFILIATED COMPANIES, OR THEIR EMPLOYEES, DIRECTORS, OR OFFICERS, BE LIABLE FOR ANY DIRECT, INDIRECT, OR INCIDENTAL DAMAGES, INJURY, LOSS, COSTS, OR EXPENSES, HOWSOEVER CAUSED, INCLUDING
6、 BUT NOT LIMITED TO SPECIAL OR CONSEQUENTIAL DAMAGES, LOST REVENUE, BUSINESS INTERRUPTION, LOST OR DAMAGED DATA, OR ANY OTHER COMMERCIAL OR ECONOMIC LOSS, WHETHER BASED IN CONTRACT, TORT (INCLUDING NEGLIGENCE), OR ANY OTHER THEORY OF LIABILITY, ARISING OUT OF OR RESULTING FROM ACCESS TO OR POSSESSIO
7、N OR USE OF THIS DOCUMENT, EVEN IF CSA GROUP HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES, INJURY, LOSS, COSTS, OR EXPENSES.In publishing and making this document available, CSA Group is not undertaking to render professional or other services for or on behalf of any person or entity or to pe
8、rform any duty owed by any person or entity to another person or entity. The information in this document is directed to those who have the appropriate degree of experience to use and apply its contents, and CSA Group accepts no responsibility whatsoever arising in any way from any and all use of or
9、 reliance on the information contained in this document. CSA Group is a private not-for-profit company that publishes voluntary standards and related documents. CSA Group has no power, nor does it undertake, to enforce compliance with the contents of the standards or other documents it publishes. In
10、tellectual property rights and ownershipAs between CSA Group and the users of this document (whether it be in printed or electronic form), CSA Group is the owner, or the authorized licensee, of all works contained herein that are protected by copyright, all trade-marks (except as otherwise noted to
11、the contrary), and all inventions and trade secrets that may be contained in this document, whether or not such inventions and trade secrets are protected by patents and applications for patents. Without limitation, the unauthorized use, modification, copying, or disclosure of this document may viol
12、ate laws that protect CSA Groups and/or others intellectual property and may give rise to a right in CSA Group and/or others to seek legal redress for such use, modification, copying, or disclosure. To the extent permitted by licence or by law, CSA Group reserves all intellectual property rights in
13、this document.Patent rightsAttention is drawn to the possibility that some of the elements of this standard may be the subject of patent rights. CSA Group shall not be held responsible for identifying any or all such patent rights. Users of this standard are expressly advised that determination of t
14、he validity of any such patent rights is entirely their own responsibility.Authorized use of this documentThis document is being provided by CSA Group for informational and non-commercial use only. The user of this document is authorized to do only the following:If this document is in electronic for
15、m:sLOADTHISDOCUMENTONTOACOMPUTERFORTHESOLEPURPOSEOFREVIEWINGITsSEARCHANDBROWSETHISDOCUMENTANDsPRINTTHISDOCUMENTIFITISIN0$ Conductor means a wire or cable, or other form of metal, installed for the purpose of conveying electric current from one piece of electrical equipment to another or to ground; E
16、ngine negative termlnaZ means the point on the engine at which the negative-battery cable is connected; Ext ernal-ignitkzi irotecticil means that the design and construction of a device is such that under design operating conditions: (a) It will not ignite a flammable hydro-carbon mixture* surroundi
17、ng the device when an ignition source causes an internal explosion; (b) It is incapable of releasing sufficient electrical or thermal energy to ignite a hydroearbon mixture; or Notes (1) It is not the intention to require such devices to be “explosion-proof“ as that term is defined in the Canadian E
18、lectrical Code pertaining to shore systems. It is intended that the protection provided be generally equivalent to that of wiring permitted by this Standard wherein a definite short or break would be necessary to produce an open spark. (2) Non-incendive equipment complying with CSA Standard C22.2 No
19、. 157, Intrinsically Safe and Non- incendive Equipment for Use in Hazardous Locations, is considered to comply. Ground means a connection to earth. The boats ground is established by a conducting connection with earth, including any conductive part of the wetted surface of a hull; Grounded means con
20、nected effectually with the general mass of the earth through a grounding path of sufficiently low impedance and having an ampacity sufficient at all times, under the most severe conditions that are liable to occur, to prevent any current in the grounding path from causing a harmful voltage to exist
21、: (a) Between the grounding conductors and exposed conducting surfaces that are in good contact with the earth; or (b) Between the grounding conductors and the surface of the earth itself; Grounding condiu,tor means a path of copper or other suitable metal whereby electrical equipment is electricall
22、y connected to ground; Machinery space means a compartment that houses one or more fuel-driven engines; Pdarized system means a system in which the grounded (white) and ungrounded conductors are connected in the same relation to all terminals and leads on all equipment in the circuit; Shore-power in
23、Zet means a recessed-male-type fitting designed for mounting on the boat and requiring a female type of connector on the shore cable in order to make the electrical connection. (c) The source of ignition is hermetically sealed; *A flammable hydro- carbon mixture is a mixture of gasoline and air or p
24、ropane and air between the lower explosive limit (LEL) and the upper explosive limit (UEL). March, 1982 10 CSA Standard C22.2 No. 183.1M1982 3. General Requirements 3.1 General requirements applicable to this Standard are given in CSA Standard C22.2 No. 0, Definitions and General Requirements. 3.2 A
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CSAC222NO1831M19821982ALTERNATINGCURRENTACELECTRICALINSTALLATIONSONBOATSFIRSTEDITIONPDF

链接地址:http://www.mydoc123.com/p-621228.html