CSA C22 2 NO 182 3-M1987-1987 Special use attachment plugs receptacles and connectors (First Edition General Instruction No 1 December 1987 General Instruction No 2 September 1989 .pdf
《CSA C22 2 NO 182 3-M1987-1987 Special use attachment plugs receptacles and connectors (First Edition General Instruction No 1 December 1987 General Instruction No 2 September 1989 .pdf》由会员分享,可在线阅读,更多相关《CSA C22 2 NO 182 3-M1987-1987 Special use attachment plugs receptacles and connectors (First Edition General Instruction No 1 December 1987 General Instruction No 2 September 1989 .pdf(64页珍藏版)》请在麦多课文档分享上搜索。
1、C22.2 No. 182.3-M1987(Ueaffirmed 2014)Special use attachment plugs, receptacles, and connectorsUpdate No. 4C22.2 No. 182.3-M1987July 2011Note: General Instructions for CSA Standards are now called Updates. Please contact CSA Information Products Sales or visit www.ShopCSA.ca for information about th
2、e CSA Standards Update Service.Title: Special Use Attachment Plugs, Receptacles, and Connectors originally published December 1987Revisions issued: General Instruction No. 2 September 1989Update 3 July 2010If you are missing any updates, please contact CSA Information Products Sales or visit www.Sho
3、pCSA.ca.The following revisions have been formally approved and are marked by the symbol delta () in the margin on the attached replacement pages:Revised Clauses 1.1, 4.3.4, 4.8.3, and 6.6.2, Figure 1, and Table B2New Clause 4.5.5Deleted NoneUpdate your copy by inserting these revised pages.Keep the
4、 pages you remove for reference. Canadian Standards Association Special Use Attachment Plugs, Receptacles, and ConnectorsJuly 2011C22.2 No. 182.3-M1987Special Use Attachment Plugs, Receptacles, and Connectors1 Scope1.1 This Standard applies to plugs, receptacles, power inlets and outlets, connectors
5、, and similar wiring devices intended for use in electronic and electrical applications as follows (see Figure 1):(a) Type 0 rated up to 8.3 A and up to 30 V rms (42 V peak);(b) Type 1A rated up to 8.3 A and from 30 V to 600 V ac or dc, or both;(c) Type 1B rated from 8.3 A up to 200 A and up to 30 V
6、 rms (42 V peak);(d) Type 2 rated from 8.3 A up to 31 A and from 30 V to 600 V ac or dc, or both;(e) Type 3 rated from 31 A up to 200 A and from 30 V to 600 V ac or dc, or both; (f) Type 4 rated from more than 200 A up to and including 1000 A, and up to 600 V ac or dc; and(g) Type 5 rated less than
7、31 A and from over 600 V up to and including 6000 V ac or dc, or both.Note: As there is a great variety of applications for products covered by this Standard, their use should be evaluated with the design and construction of the end use application and cannot be solely judged by the requirements of
8、this Standard.1.2 This Standard does not apply to(a) appliance plugs covered in CSA Standard C22.2 No. 57;(b) attachment plugs, receptacles, and similar wiring devices intended for use in hazardous locations covered in CSA Standard C22.2 No. 159;(c) general use receptacles, attachment plugs, and sim
9、ilar wiring devices covered in CSA Standard C22.2 No. 42;(d) industrial type, special use attachment plugs, receptacles, equipment power inlets and outlets, and connectors covered in CSA Standard C22.2 No. 182.1-M; or(e) industrial locking type attachment plugs, receptacles, and connectors covered i
10、n CSA Standard C22.2 No. 182.2-M.2 Definitions2.1 The following definitions apply in this Standard:Connector (cable connector) a receptacle that is intended to provide power with means for attachment to electrical conductors.Contact a conductive element in a component that mates with a corresponding
11、 element to provide an electrical path.Elastomer a macromolecular material that at room temperature returns rapidly to approximately its initial dimensions and shape after substantial deformation by a weak stress and release of the stress.Enclosure the case or housing into which the insulator and co
12、ntacts are assembled.Equipment power inlet a male contact device designed for permanent, flush mounting on utilization equipment and intended to supply power to that equipment by insertion of a cord connector.11(Replaces p. 11, July 2010)C22.2 No. 182.3-M1987 Canadian Standards AssociationJuly 2011F
13、ield wiring terminal a terminal to which power supply, control, or equipment grounding connections will be made in the field when the device is installed.Insulator that portion of a device that provides for separation of and support of contacts.Locking retaining device a mechanical arrangement that
14、holds a plug or connector in position when it is in proper engagement and prevents its unintentional withdrawal.Plug (attachment plug) a device that is intended to receive power when coupled with a mating device, and that establishes connection between conductors of the two assemblies.Power inlet a
15、permanently mounted plug intended to receive power from a cable connector.Receptacle (outlet) a device intended to provide power to an inserted plug and that is usually installed as a fixed outlet.Switched outlet an outlet with an associated or integral switching device to disconnect the supply from
16、 the outlet contacts.Terminal an accessible conductive part provided on a contact for connecting a conductor.Terminal, wire binding screw a terminal in which the conductor is clamped under the head of the screw and the clamping pressure is applied directly by the head of the screw.Thermoplastic a pl
17、astic that repeatedly can be softened by heating and hardened by cooling through a temperature range characteristic of the plastic, and, which in the softened state, can be shaped by flow into articles by moulding or extrusion.Thermoset a material that, after having been cured by heat or other means
18、, is substantially infusible and insoluble.Weatherproof so constructed or protected that exposure to the weather will not interfere with safe operation.3 General Requirements3.1 GeneralGeneral requirements applicable to this Standard are given in CSA Standard C22.2 No. 0.3.2 Reference Publications3.
19、2.1 Where reference is made to CSA Standards of the Canadian Electrical Code, Part II, such reference shall be considered to refer to the latest edition and revision thereto, unless otherwise specified. This Standard refers to the following such Standards and the year dates shown indicate the latest
20、 editions available at the time of printing:C22.2 No. 0-M1982,General Requirements Canadian Electrical Code, Part II;CAN/CSA-C22.2 No. 0.17-00 (R2009),Evaluation of Properties of Polymeric Materials;C22.2 No.0.3-M1985Test Methods for Electrical Wires and Cables;C22.2 No. 42-M1984,General Use Recepta
21、cles, Attachment Plugs, and Similar Wiring Devices;(Replaces p. 12, July 2010)12 Canadian Standards Association Special Use Attachment Plugs, Receptacles, and ConnectorsJuly 2011C22.2 No. 57-M1985,Appliance Plugs for Heater Cord Sets;C22.2 No. 65-1956,Wire Connectors;C22.2 No. 159-1982,Attachment Pl
22、ugs, Receptacles and Similar Wiring Devices for Use in Hazardous Locations, Class I, Groups A, B, C, and D, Class II, Group G and in Coal or Coke Dust, and in Gaseous Mines;C22.2 No. 182.1-M1987,Industrial Type, Special Use Attachment Plugs, Receptacles, and Connectors;C22.2 No. 182.2-M1987,Industri
23、al Locking Type, Special Use Attachment Plugs, Receptacles and Connectors;C22.2 No. 188-M1983,Splicing Wire and Cable Connectors.3.2.2 Where reference is made to the following Publications such reference shall be considered to refer to that edition listed below:ANSI (American National Standards Inst
24、itute)C73-1973,American National Standard on Dimensions of Attachment Plugs and Receptacles.IEC (International Electrotechnical Commission)IEC 320-1981,Appliance Couplers for Household and Similar General Purposes.4 Construction4.1 Component PartsA component of a product covered by this Standard sha
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CSAC222NO1823M19871987SPECIALUSEATTACHMENTPLUGSRECEPTACLESANDCONNECTORSFIRSTEDITIONGENERALINSTRUCTIONNO1DECEMBER1987GENERALINSTRUCTIONNO2SEPTEMBER1989PDF

链接地址:http://www.mydoc123.com/p-621226.html