1、B140.9.1-1972(reaffirmed 2011)Portable liquid fuelled catalytic appliancesBlank pageCSA Standards Update ServiceB140.9.1-1972June 1972Title: Portable liquid fuelled catalytic appliancesPagination: 14 pages To register for e-mail notification about any updates to this publicationgo to www.shop.CSA.ca
2、click on E-mail Services under MY ACCOUNTclick on CSA Standards Update ServiceThe List ID that you will need to register for updates to this publication is 2000213.If you require assistance, please e-mail techsupportcsa.ca or call 416-747-2233.Visit CSAs policy on privacy at www.csagroup.org/legal t
3、o find out how we protect your personal information.Blank pageCSA STANDARD B140.9.1-1972 PORTABLE LIQUID FUELLED CATALYTIC APPLIANCES PUBLISHED, JUNE, 1972 BY THE CANADiAN STANDARDS ASSOCIATION (INCORPORATED 1919) 178 REXDALE BOULEVARD REXDALE 603, ONTARIO, CANADA COPYRIGHT CANADIAN STANDARDS ASSOCI
4、ATION-I972 CSA CERTIFICATION The Canadian Standards Association pro- vides certification services for manufacturers who, under licence from CSA, wish to use the appropriate registered CSA Marks on certain products of their manufacture to indicate con- formity with a CSA Standard. CSA Certification f
5、or a number of products is provided on a voluntary basis in the interest of maintaining agreed-upon standards of qual- i ty, performance, interchangeability, or safety and, where appropriate, it forms the basis or acceptance by inspection authorities responsible for enforcement of regulations. Where
6、 feasible, programmes will be de- veloped for additional products for which certification is desired by producers, consum- ers, or other interests. PORTABLE LIQUID FUELLED CATALYTIC APPLIANCES 3 CONTENTS Committee on Oil Burning Appliance Standards . Preface . Reference Publications STANDARD 1 . Sco
7、pe . 2 . Definitions 3 . Basic General Requirements . 3.1 Reference PubIications 3.2 General 4 . Construction Requirements 5 . Marking . 6 . Instructions . 7 . Tests . . 7.1 General . 7.2 Rated Output Capacity . 7.3 Carbon Monoxide . 7.4 Unburned Hydrocarbons . 7.5 Leakage Test . 7.7 Temperature of
8、Materials 7.8 Canopy Test . 7.9 Draping Test . 7.10 Gasket Test 7.11 Extinction Test . 8 . Fuel Specifications for Portable Liquid Fuelled Catalytic Appliances 7.6 Stability . 4 5 5 7 7 7 7 8 9 9 10 10 10 11 11 12 13 13 13 13 13 13 13 13 4 CSA STANDARD B140.9.1 COMMITTEE ON OIL BURNING APPLIANCE STA
9、NDARDS G. C. STAPLETON (Chairman) Honeywell Limited, Scarborough A. G. REED (Vice-Chairman) Honeywell Limited, Scarborough P. C. BODETT .Duo-Therm Division of Motor Wheel Corpora- tion, Indiana A. E. BRIDGES .Alberta Department of the Provincial Secretary, Edmonton (Representing Council on Fire Safe
10、ty) W. C. Cmss Weil-McLain (Canada) Limited, Bramalea A. DRON F. FEITH G. E. FISHER . Ontario Hydro, Toronto . .Saskatchewan Department of Labour, Regina . Terry Industries, Poinle Claire J. E. FORSYTH .The Canadian Coleman Company, Limited, To- ronto J. W. INGRAM .Shell Canada Limited, Toronto (Rep
11、resenting CSA Committee on Installation Code for Oil Burning Equipment) A. I). RENT . .National Research Council of Canada, Ottawa E. LEDWINKA Anthes Eastern Limited, Toronto S. S. MAJURY . Factory Mutual Engineering Association, Toronto W. F. MALSBARY Malsbary Manufacturing Company, Uniontown, Penn
12、sylvania J. F. MITCHELL MacKinnon Mitchell marking and instruction require- ments are also included. 1.4 Portable appliances having materials or forms of construction differing from those contemplated or covered by these requirements but meeting the intent of the requirements, may be examined and te
13、sted according to the intent of the requirements, and if found to be substantially equivalent, may be given recognition. 1.5 Portable appliances which comply with these requirements shall not be acceptable if, when examined and tested, they are found to have additional features which impair the resu
14、lts contemplated by the requirements of this Standard. 2. DEFINITIONS 2.1 Definitions of terms used in this Standard are listed in CSA Standard B139, Installation Code for Oil Burning Equipment, and the supplementary definitions as follows shall apply: Canopy means a ventilated cover to shield the b
15、urner head during operation; Catalytic combustion means rapid, flameless, oxidation of a fuel in the presence of a catalyst; Catalytic layer means that part of the burner head which contains a catalyst and any supportkg screens; Burner head (catalytic combustion head) means the section of the applia
16、nce where evaporation and combustion of the fuel is intended to take place; Portable liquid fuelled cataIyeic appliance means a hand portable flame- less space heating appliance with integral fuel storage; Snuffer means a cap to fit over the burner head to extinguish combustion. 3. BASIC GENERAL REQ
17、UIREMENTS 3.1 Reference Publications. This Standard makes reference to the following publications, and where such reference is made it shall be to that edition of such publication as listed below: 8 CSA STANDARD B148.9.1 CSA Standards B 139-1 97 1, Installation Code for Oil Burning Equipment; B 140.
18、0-1 97 1, General Requirements for Oil Burning Equip- ment. CGBV Specification 4-GP-8 1-6 1, Cloth: ,Cotton, Cheesecloth. “Canadian Government Specifications Board. 3.2 General 3.2.8 The appliance shall not produce carbon monoxide. This require- ment shall be deemed met when the appliance is tested
19、in accordance with Clause 7.3 and a concentration of carbon monoxide not in excess of .05 per cent is produced in a room with no air changes occurring during combustion of the amount of fuel necessary to reduce the oxygen content of the room to a quantity equal to 15.1 per cent by volume, corrected
20、to 60F and 30.0 inches of mercury. 3.2.2 The appliance shall not emit unburned hydrocarbons in a quantity that exceeds 50 per cent of the lower explosive limit for the fuel when tested in accordance with Clause 7.4. 3.2.3 A device shall be provided for extinguishing the appliance and shall be such t
21、hat complete extinction results in accordance with Clause 7.11. 3.2.4 The extinction device shall be of a design which cannot be acci- dentally dislodged under normal use and handling. 3.2.5 The appliance, when empty or full, or partially filled with any amount of fuel, shall be capable of being tip
22、ped in any direction, to an angle of 35 degrees from the normal upright position without overturning on being released. 3.2.6 The appliance while operating or not operating and filled in accordance with Clause 7.1.7 shall not permit the escape of liquid fuel. This requirement shall be deemed met if
23、the appliance: (a) Will not leak liquid fuel when tilted to any angle up to 40 degrees in any direction from the normal upright position; and (b) When lying on its side for a period of at least 10 minutes, will not leak more than 2Y2 ounces of liquid fuel in any given minute. 3.2.7 The catalytic lay
24、er shall be homogeneous and the joint between the catalytic layer and the rim of the burner head shall be vapour tight. 3.2.8 The catalytic layer, if not self-supporting, shall be adequately supported. 3.2.9 A canopy shall be provided to protect and prevent contact of the catalytic layer while the a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CSAB140911972PORTABLELIQUIDFUELLEDCATALYTICAPPLIANCESFIRSTEDITIONPDF

链接地址:http://www.mydoc123.com/p-621111.html