CSA B140 3-1962 Oil burning stoves and water heaters (First Edition).pdf
《CSA B140 3-1962 Oil burning stoves and water heaters (First Edition).pdf》由会员分享,可在线阅读,更多相关《CSA B140 3-1962 Oil burning stoves and water heaters (First Edition).pdf(48页珍藏版)》请在麦多课文档分享上搜索。
1、B140.3-1962(reaffirmed 2011)Oil burning stoves and water heatersBlank pageCSA STANDARD B140.3-1962 (Reaffirmed 2001) OIL BURNING STOVES AND WATER HEATERS PUBLISHED, MARCH, 1962 BY THE CANADIAN STANDARDS ASSOCIATION (INCORPORATED 1919) 235 MONTREAL ROAD OTTAWA 2, CANADA COPYRIGHT REGISTERED, CANADA,
2、1962 Blank pageCSA Standards Update ServiceB140.3-1962March 1962Title: Oil burning stoves and water heatersPagination: 40 pagesTo register for e-mail notification about any updates to this publicationgo to www.shop.CSA.caclick on E-mail Services under MY ACCOUNTclick on CSA Standards Update ServiceT
3、he List ID that you will need to register for updates to this publication is 2000205.If you require assistance, please e-mail techsupportcsa.ca or call 416-747-2233.Visit CSAs policy on privacy at www.csagroup.org/legal to find out how we protect your personal information.Blank pageClause (b) Model
4、or type number of the complete unit; (c) Maximum input in suitable units, Le. cubic centirnetres per minute, or gaIlons per hour, or pounds per hour (refer to the Combustion Test of Clause 7.2); (d) For oil burning stoves, the heat output in Btu per hour (refer to the Heat Output Test of Clause 7.3)
5、; (e) Electrical ratings, where applicable, as specified in CSA Standard C22.2 So. 3-1961, Electrical Features of Fuel-Burning Equipment (Gas and Oil). The above marking shall be on a non-removable panel of the unit, and shall be readily visible. Soms: 1. Inputs specified in gallons per hour are to
6、be qiralijied by the appropriate measurement, e.g. Imperial (Imp.) or United States (US.). 2. The heat output marking of Clause 5.2 (d) may be less than that actually determined by test. 5.3 Identification Marking for Space Heaters 5.3.1 Each space heater shall bear an identification marking, which,
7、 if the heater were involved in a fire, wouId be readable after the fire. XOTE: Marking embossed OT cast in metal having a melting point not less than l,dOOF, is considered satisfactory. 5.3.2 The identification marking shall be the rnark- ing required by Clause 5.2 items (a) and (b). 5.3.3 LnIess t
8、he nameplate, bearing the marking required by Clause 5.2 meets the requirements of Clause 5.3.1, the identification marking shall be on a separate nameplate, in addition to the nameplate re- quired by Clause 5.2, or shaIl be embossed or cast into some prominent permanent part of the heater. 5.3.4 If
9、 a separate nameplate, bearing the identi- fication marking is used, it shall meet the requirements of Clause 5.3.1 and shall be permanently secured to the heater adjacent to the nameplate required by Clause 5-2- 5.4 Cautions 5.4.1 The following cautions, or equivalent word- ings, shall be located o
10、n the appliance so that they are readily visible to the operator when lighting the burner: (a) “l7AIT UNTIL THE BURNER IS COOL BEFORE LIGHTIX-C” ; and (b) “IF THE BURNER IS FLOODED, DRAIS BEFORE LIGHTISG”. 5.4.2 The above cautions shall be on a metal plate, or the equivalent, or a temperature-resist
11、ant marking shall be used. 60: The aboae markings may be !muted on the inside surface f a cabinet door that provides access to the lzEhting door. 3.5 Installation Markings 5.51 Each unit shall bear a permanent” marking giving the minimum clearances, when installed from the unit to adjacent combustib
12、le construction. Permanent, in this case, means as permanent as metalfoil nameplates. 5.5.2 Each unit which is not to be installed on com- bustible flooring shall bear a marking or caution equivalent to: “IYSTAI,I, OSLY OS -4 SOS-COMBCSTIBLE FLOOR1 SG” . 5.5.3 The installation markings shaIl be loca
13、ted adjacent to or combined with the data required by Clause 5.2. 5.6 Field Assembled Units 5.6.1 %hen the unit, and the burner, or other components, are shipped as separate items intended for field-assembly, the following marking or its equiva- lent shall appear on the unit in a place where the det
14、ails may be readily seen : “FOR USE OSLY WITH (specify the manufacturer of the burner) OIL BURKER hlODEL (OR TYPE)”. 5.6.2 The above marking shall be located adjacent to, or combined with the details required in Clause 5.2. YOTS: The aboze marking may b? on a substantial paper slicker, water transfe
15、r, or the eqwizzalent. Muy, 19631 Rerision No. Z R140 3-1067 CSA CERTIFICATION The requirements of this CSA Standard have been made mandatory by most provincial or municipal authorities in Canada, and these authorities demand that before products covered by this CSA Standard may be offered or sale o
16、r placed in service, representative samples shall have been investigated by a designated labor- atory which shall certify that they meet the requirements of the Standard. The registered monogram mark , which is controlled by the CSA Testing Laboratories, is used to indicate this certification. The C
17、SA certification marks CSA STANDARD or CSA STD are not acceptable for this purpose. For complete detaiis, inquire directly to Manager, CSA Testing Laboratories, 178 Rexdale Boulevard, TORONTO, Rexdale Post Office, Ontario. STANDARDS Address all orders for CSA Standards to General Manager, Canadian S
18、tandards Association, 235 Montreal Road, Ottawa 2, Ontario. A complimentary copy of the complete list of CSA publications will be provided on request. OIL BURNING STOVES AND WATER HEATERS 3 CONTENTS Page 6 Preface 7 Reference Publications 7 List of Members of Committee on Oil Burning Equipment . STA
19、NDARD 1 . Scope 2 . Definitions . 9 9 3 . General Requirements . 11 3.1 General 11 3.2 Oil Burner 11 3.3 Electrical Features . 11 11 3.4 Methods of Assembly and Shipment . 4 . Construction . 11 4.1 General . 11 4.2 Accessibility of Parts 11 4.3 Location of Fuel Lines and Fuel Components 12 4.4 Casin
20、gs and Liners 12 4.5 Lubrication of Motors . 12 4.6 Flue Collars 12 4.7 Flue-Gas Passages 13 4.8 Draft Regulators . 13 4.9 Heating Surfaces . 13 4.10 Levelling 14 4.11 Glass Containers . 14 4.12 Anti-Flooding Devices . 14 4.13 Valves 14 4.14 Integral Tanks . 14 4.15 Fuel Lines and Fittings 15 4.16 F
21、uel Oil Filters 15 3.17 Observation of the Flame Zone . 15 4.18 Refractory MateriaIs 16 4.19 Metal Fireboxes 16 4.20 Flue Baffles and Flame Baffles . 16 4.2 1 Insulating Materials 16 4.22 Safety Limit Controls . 16 4.23 Water Heaters . I6 4 CSA STANDARD B140.3 Page 4.24 Meansof Ignition 17 4.25 Moun
22、ting 17 4.26 Flow Rate . 17 5 . Marking . . . 17 5.1 General . 17 5.2 Details Required 17 5.3 Cautions . 18 5.4 Installation Clearances . 18 5.5 FieId AssembIedUnits 18 6 . Instructions 18 6.1 General 18 6.2 Installation Instructions 18 6.3 Operating Instructions . 20 7 . Normal Unit Tests 21 7.1 Ge
23、neral 21 7.2 Combustion . 21 7.2.1 Test Requirements . 21 7.2.1.1 Combustion . 21 7.2.1.2 Smoke Density 21 7.2.1.3 Maximum Flue-Gas Temperature 21 7.2.1.4 Minimum Flue-Gas Temperature 22 7.2. I . 5 Operating Flow-Rate . 22 7.2.2 Test Procedures 22 7.3 Heat Output - Oil Burning Stoves 23 7.3.1 Test R
24、equirements . 23 7.3.1.1 Heat Output 23 7.3.1.2 Optional Mechanical Draft 23 7.3.2 Test Procedures 23 7.3.3 Determination of Heat Output 23 7.4 Limit Control Performance (Water Heaters) 24 7.5 Hydrostatic Pressure (Water Heaters) 24 7.6 Normal Temperatures 24 7.6.1 Test Requirements . 24 7.6.2 Test
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CSAB14031962OILBURNINGSTOVESANDWATERHEATERSFIRSTEDITIONPDF

链接地址:http://www.mydoc123.com/p-621107.html