1、ANSI Z21.54a-2006 CSA 8.4a-2006 Addenda to the Second Edition of ANSI Z21.54-2002 CSA 8.4-2002 American National Standard/ CSA Standard For Gas Hose Connectors For Portable Outdoor Gas-Fired Appliances Preface The standards set forth herein apply to the second edition of the Standard for Gas Hose Co
2、nnectors For Portable Outdoor Gas-Fired Appliances ANSI Z21.54-2002 CSA 8.4-2002, and supersede corresponding standards therein. Following their preparation by the supervising Technical Advisory Group, they were accepted by the American National Standards Institute (ANSI) and the Interprovincial Gas
3、 Advisory Council (IGAC), and subsequently approved. NOTE: Changes, other than editorial, are denoted by a vertical line in the margin. APPROVED IGAC August 25, 2005 January 4, 2006 American National Standards Institute, Inc. Interprovincial Gas Advisory Council Effective in Canada March 1, 2007 Sta
4、ndard Developer CSA AMERICA, INC. CANADIAN STANDARDS ASSOCIATION 8501 East Pleasant Valley Road 5060 Spectrum Way, Suite 100 Cleveland, Ohio 44131 Mississauga, Ontario, Canada L4W 5N6 Printed In Canada Published - January 2006 Copyright 2006 Canadian Standards Association Permission is granted to re
5、publish material herein in laws or ordinances, and in regulations, administrative orders, or similar documents issued by public authorities. Those desiring permission for other republication should consult Canadian Standards Association at 5060 Spectrum Way, Suite 100, Mississauga, Ontario, Canada L
6、4W 5N6. Copyright 2006 CSA America, Inc. Permission is granted to republish material herein in laws or ordinances, and in regulations, administrative orders, or similar documents issued by public authorities. Those desiring permission for other republication should consult CSA America, Inc. at 8501
7、East Pleasant Valley Road, Cleveland, Ohio 44131.1Addenda To American National Standard/CSA Standard For Gas Hose Connectors For Portable Outdoor Gas-Fired Appliances Part I: Construction 1.7 Installation 1.7.2 Installation. The instructions shall include, as a minimum, installation instructions to
8、the effect that: a. CAUTION: All adapters (unions) supplied with the connector must be used unless the appliance valve has a union connection. No attempt shall be made to connect the fittings on the connector directly to the threaded rigid pipe ends of the equipment manifold or the outlet of the fue
9、l gas piping system. b. The final assembly must be tested for leaks. CAUTION: Test for leaks only with leak test solution. Rinse with clear water after leak test to remove any corrosive residue. DO NOT USE OPEN FLAME TO TEST FOR GAS LEAKS. The installation instructions shall be accompanied by illust
10、rations or diagrams depicting the proper assembly of fittings, adapters or other parts. 2Part II: Performance 2.1 General 2.1.1 During test for compliance with this standard, connections shall be made using the maximum torque specified in Table VIII, Applied Torque During Reconnection of Fittings Te
11、st, unless otherwise specified. 2.1.2 Unless otherwise specified, all tests for leakage in Part II shall be made consistent with section 2.2, Leakage. 2.2 Leakage A connector and its fittings shall not leak. For the purpose of this section, leakage is defined as a flow rate in excess of 10cm3/hr at
12、3 psi (20.7 kPa). Method of Test This test shall be conducted at room temperature. One end of the connector shall be attached to a flow measuring device, capable of accurately indicating the allowable flow rate, and a pneumatic system, capable of supplying clean air at a test pressure of 3 psi (20.7
13、 kPa). An airtight connection shall be made at the opposite end of the connector. Air shall be admitted to the system slowly and maintained at the specified test pressure. The leakage rate shall be measured and shall not exceed 10 cm3/hr of air corrected to standard conditions of 30 in Hg column (10
14、1.3 kPa) and 60F (15.5C). 2.4 Strength, Flexibility And Temperature Resistance 2.4 Of Conduit 2.4.1 Unless otherwise stated, each test specified in this section shall consist of three tests: one performed with a connector which has been maintained at -40F (-40C) for 6 hours immediately preceding the
15、 test, one with a connector which has been maintained at 200F (93.5C) in dry air for six hours immediately preceding the test, and one with a connector which has been maintained at 200F (93.5C) in air saturated with water vapor for 6 hours immediately preceding the test. During the conduct of these
16、tests, connectors which have been exposed to elevated temperatures shall not soften sufficiently to become sticky or for any material to ooze through the covering or inside the hose. 2.4.2 Connectors shall withstand, without bursting or leakage, a hydrostatic pressure of 25 lb/in2(172.4 kPa). 3Metho
17、d of Test During this test, a quick-disconnect device supplied as an end connection shall be removed and replaced with a plug. A connector of the shortest length provided by the manufacturer shall be assembled in a hydraulic pressure test system, including a pump, gage and heavy-duty pipe fittings,
18、capable of sustaining the desired pressure, care being taken to free all air from the system. The applied pressure shall be maintained for 1 minute. If no bursting or leakage occurs during this period, this provision shall be deemed met. This test shall be applied to each nominal diameter, type and
19、material of connector submitted. 2.4.3 Connectors shall be able to withstand, without leakage and without becoming detached, a steady lengthwise pull of 400 lb/in (70.1 kN/m) of nominal inside diameter for 1 minute. Method of Test During this test, a quick-disconnect device supplied as an end connec
20、tion shall be removed and replaced with a plug. One end of a connector of the shortest length provided by the manufacturer shall be securely attached to a fixed pipe to which an air supply system and pressure gage is connected. The other end shall be securely attached in a similar manner to a closed
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CSA84A2006GASHOSECONNECTORSFORPORTABLEOUTDOORGASFIREDAPPLIANCESADDENDATOTHESECONDEDITIONPDF

链接地址:http://www.mydoc123.com/p-621051.html