《CEN TS 15912-2012 Durability of reaction to fire performance - Classes of fireretardant treated wood-based product in interior and exterior end use applications《耐用性反应火性能 类防燃剂对待木质产品.pdf》由会员分享,可在线阅读,更多相关《CEN TS 15912-2012 Durability of reaction to fire performance - Classes of fireretardant treated wood-based product in interior and exterior end use applications《耐用性反应火性能 类防燃剂对待木质产品.pdf(35页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationDurability of reaction to fire performance Classes of fire-retardant treated wood-based product in interior and exterior end use applicationsPD CEN/TS 15912:2012National foreword
2、This Published Document is the UK implementation of CEN/TS 15912:2012.The UK participation in its preparation was entrusted to Technical CommitteeB/543, Round and sawn timber.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not pu
3、rport to include all the necessary provisions of acontract. Users are responsible for its correct application. The British Standards Institution 2012Published by BSI Standards Limited 2012ISBN 978 0 580 65579 1ICS 71.100.50Compliance with a British Standard cannot confer immunity fromlegal obligatio
4、ns.This Published Document was published under the authority of theStandards Policy and Strategy Committee on 30 April 2012.Amendments issued since publicationAmd. No. Date Text affectedPUBLISHED DOCUMENTPD CEN/TS 15912:2012TECHNICAL SPECIFICATION SPCIFICATION TECHNIQUE TECHNISCHE SPEZIFIKATION CEN/
5、TS 15912 April 2012 ICS 71.100.50 English Version Durability of reaction to fire performance - Classes of fire-retardant treated wood-based product in interior and exterior end use applications Durabilit des performances de raction au feu - Classement des produits base de bois ignifugs pour utilisat
6、ion finale en intrieur et en extrieur Dauerhaftigkeit des Verhaltens bei Brandeinwirkung - Klassen der mit Feuerschutzmitteln behandelten Holzprodukte fr Anwendungen im Innen- und Auenbereich This Technical Specification (CEN/TS) was approved by CEN on 14 February 2012 for provisional application. T
7、he period of validity of this CEN/TS is limited initially to three years. After two years the members of CEN will be requested to submit their comments, particularly on the question whether the CEN/TS can be converted into a European Standard. CEN members are required to announce the existence of th
8、is CEN/TS in the same way as for an EN and to make the CEN/TS available promptly at national level in an appropriate form. It is permissible to keep conflicting national standards in force (in parallel to the CEN/TS) until the final decision about the possible conversion of the CEN/TS into an EN is
9、reached. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia,
10、 Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2012 CEN All rights of exploitation in any form and by any means reserved worldw
11、ide for CEN national Members. Ref. No. CEN/TS 15912:2012: EPD CEN/TS 15912:2012CEN/TS 15912:2012 (E) 2 Contents Page Foreword 4Introduction .51 Scope 62 Normative references 63 Terms and definitions .64 Symbols 75 Requirements .75.1 Wood-based products and non-fire-retardant coating systems .75.2 Re
12、action to fire performance 85.2.1 Initial classification for reaction to fire 85.2.2 Reaction to fire performance before and after accelerated or natural weathering .85.3 Durability of reaction to fire performance .95.3.1 General 95.3.2 DRF Class ST .95.3.3 DRF Class INT1 95.3.4 DRF Class INT2 95.3.
13、5 DRF Class EXT .96 Practices to use the DRF classification system 117 Classification report . 11Annex A (informative) Test methods 13A.1 Hygroscopic properties of fire-retardant treated wood-based products including those with fire-retardant coatings . 13A.1.1 General . 13A.1.2 Field of application
14、 . 13A.1.3 Sampling, sample handling and preparation . 14A.1.4 Test method . 15A.2 Accelerated weathering of fire-retardant treated wood for fire testing . 17A.2.1 General . 17A.2.2 Field of application . 18A.2.3 Sampling, sample handling and preparation . 18A.2.4 Test method . 19A.3 Building materi
15、als and components in the vertical position: Exposure to accelerated climate strains . 21A.3.1 General . 21A.3.2 Field of application . 21A.3.3 Sampling 21A.3.4 Test method . 22Annex B (informative) Example of classification report . 26B.1 Classification report: Durability classes of reaction to fir
16、e performance of fire-retardant wood-based products in interior and exterior end use applications according to CEN/TS 15912 26B.1.1 Product 26B.1.2 Product specification . 26B.1.3 Requirements 27B.1.4 Evaluation documents . 27B.1.5 Durability of reaction to fire performance (DRF) Class 28B.1.6 Appli
17、cability of DRF Class . 28PD CEN/TS 15912:2012CEN/TS 15912:2012 (E) 3 B.1.7 Service life 29Bibliography 30PD CEN/TS 15912:2012CEN/TS 15912:2012 (E) 4 Foreword This document (CEN/TS 15912:2012) has been prepared by Technical Committee CEN/TC 175 “Round and sawn timber”, the secretariat of which is he
18、ld by AFNOR. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. According to the CEN/CENELEC Internal Regulations, the national standards
19、 organisations of the following countries are bound to announce this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland
20、, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. PD CEN/TS 15912:2012CEN/TS 15912:2012 (E) 5 Introduction Fire-retardant treatments may considerably improve the reaction to fire properties of wood and wood-based products and these may result in wood
21、 having the highest fire-resisting characteristics achievable with any combustible product. However, the reaction to fire performance may be reduced by exposure to wet and/or humid conditions 1 and the ability of treatments to continue to perform even when exposed to these conditions needs to be dem
22、onstrated. Two aspects of fire durability of the fire-retardant treatment of wood-based products need to be considered. One is the risk for high moisture content and migration of the fire-retardant chemicals within the wood product and salt crystallisation on the product surface. These hygroscopic p
23、roperties of the treated wood-based product can be evaluated by exposure to high relative humidity. The other aspect is the risk for decreased fire performance due to loss of the fire-retardant chemicals by leaching in exterior applications, e.g. facade claddings. Maintained fire performance after w
24、eathering needs to be verified. The Technical Specification is based on a Nordtest standard 15 and on experience from North America 7 12. PD CEN/TS 15912:2012CEN/TS 15912:2012 (E) 6 1 Scope This European Technical Specification describes the characteristics which fire-retardant treated wood products
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CENTS159122012DURABILITYOFREACTIONTOFIREPERFORMANCECLASSESOFFIRERETARDANTTREATEDWOODBASEDPRODUCTININTERIORANDEXTERIORENDUSEAPPLICATIONS

链接地址:http://www.mydoc123.com/p-592597.html