CEN TR 16013-2-2010 Workplace exposure - Guide for the use of direct-reading instruments for aerosol monitoring - Part 2 Evaluation of airborne particle concentrations using Optica.pdf
《CEN TR 16013-2-2010 Workplace exposure - Guide for the use of direct-reading instruments for aerosol monitoring - Part 2 Evaluation of airborne particle concentrations using Optica.pdf》由会员分享,可在线阅读,更多相关《CEN TR 16013-2-2010 Workplace exposure - Guide for the use of direct-reading instruments for aerosol monitoring - Part 2 Evaluation of airborne particle concentrations using Optica.pdf(28页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationPD CEN/TR 16013-2:2010Workplace exposure Guidefor the use of direct-readinginstruments for aerosolmonitoringPart 2: Evaluation of airborne particleconcentrations using Optical Pa
2、rticleCountersPD CEN/TR 16013-2:2010 PUBLISHED DOCUMENTNational forewordThis Published Document is the UK implementation of CEN/TR 16013-2:2010.The UK participation in its preparation was entrusted to TechnicalCommittee EH/2/2, Work place atmospheres.A list of organizations represented on this commi
3、ttee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. BSI 2010ISBN 978 0 580 69046 4ICS 13.040.30Compliance with a British Standard cannot confer immunity fromlegal obl
4、igations.This Published Document was published under the authority of theStandards Policy and Strategy Committee on 31 2010Amendments issued since publicationDate Text affectedAugustTECHNICAL REPORT RAPPORT TECHNIQUE TECHNISCHER BERICHT CEN/TR 16013-2 May 2010 ICS 13.040.30 English Version Workplace
5、 exposure - Guide for the use of direct-reading instruments for aerosol monitoring - Part 2: Evaluation of airborne particle concentrations using Optical Particle CountersExposition au poste de travail - Guide dutilisation des instruments lecture directe pour la surveillance des arosols - Partie 2 :
6、 Evaluation des concentrations de particules en suspension dans lair laide de compteurs optiques de particules Exposition am Arbeitsplatz - Leitfaden fr die Anwendung direkt anzeigender Gerte zur berwachung von Aerosolen - Teil 2: Ermittlung der Konzentration Luft getragener Partikel mit optischen P
7、artikelzhlern This Technical Report was approved by CEN on 13 March 2010. It has been drawn up by the Technical Committee CEN/TC 137. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hung
8、ary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centr
9、e: Avenue Marnix 17, B-1000 Brussels 2010 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. CEN/TR 16013-2:2010: ECEN/TR 16013-2:2010 (E) 2 Contents Page Foreword 4Introduction .51 Scope 62 Principles of the method .72.1 Light scatterin
10、g 72.2 Working principle.73 OPC performance characteristics 84 Number and mass concentrations .85 Mass concentrations of thoracic and respirable aerosol fractions 96 OPC use . 106.1 General . 106.2 Airflow adjustment 116.3 Calibration of particle count response . 116.4 Calibration of particle diamet
11、er response 116.5 Mass concentration response . 117 Fundamental and practical limitations . 127.1 Refraction index and particle density . 127.2 Forward scattering instruments 127.3 Limitation in particle size . 127.4 Coincidence error and concentration limitation 127.5 Aerosols from several sources
12、. 128 Instrumentation characteristics 138.1 Aspiration system . 138.2 Integrated collection filter 138.3 Sampling head 138.4 Optical cell . 138.5 Electronics . 138.6 Case of laser instruments 139 Aerosol measurement by OPC 139.1 Operating procedure 139.2 Cartography of workplace . 149.3 Working shif
13、t monitoring . 149.4 Sampling record 149.5 Cleaning and maintenance 14Annex A (informative) Evaluation of an OPC as an instrument for thoracic and respirable mass concentrations 15A.1 Introduction to workplace evaluation . 15A.2 Procedure for field comparison of the OPC with the reference sampler 15
14、A.2.1 General . 15A.2.2 Comparison of a static OPC with a static reference sampler 16A.2.3 Comparison of mass concentrations for the respirable or thoracic aerosol fractions calculated from OPC data with a reference sampler . 16A.3 Calculation methods 16A.3.1 General . 16A.3.2 Estimation of the corr
15、ection coefficient . 16A.3.3 Exclusion of outliers 17PD CEN/TR 16013-2:2010CEN/TR 16013-2:2010 (E) 3 A.3.4 Residual uncertainty after transformation by the correction function 17A.3.5 Equivalence 17A.4 Periodic validation . 17A.5 Documentation 18A.5.1 General . 18A.5.2 Description of the OPC and the
16、 reference sampler . 18A.5.3 Critical review of sampling process 18A.5.4 Circumstances of field comparison 18A.5.5 Details of experimental design 18A.5.6 Data analysis 18A.5.7 Equivalence 19A.6 Nomenclature . 19Annex B (informative) Example for the determination of the correction coefficient for an
17、OPC . 20Bibliography 23PD CEN/TR 16013-2:2010CEN/TR 16013-2:2010 (E) 4 Foreword This document (CEN/TR 16013-2:2010) has been prepared by Technical Committee CEN/TC 137 “Assessment of workplace exposure to chemical and biological agents”, the secretariat of which is held by DIN. Attention is drawn to
18、 the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. CEN/TR 16013, Workplace exposure Guide for the use of direct-reading instruments for aerosol monitoring, co
19、nsists of the following parts: Part 1: Choice of monitor for specific applications Part 2: Evaluation of airborne particle concentrations using Optical Particle Counters Part 3: Evaluation of airborne particle concentrations using photometers (in preparation) PD CEN/TR 16013-2:2010CEN/TR 16013-2:201
20、0 (E) 5 Introduction Optical Particle Counters (OPC) count airborne particles and are therefore suitable for measuring concentrations expressed in number of particles per unit volume of air. Counting-based measurement of mass concentration and particle size estimation is indirect: a number of assump
21、tions and approximations are made to access the information sought. Nevertheless, optical particle counters can be used to evaluate the efficiency of preventive actions and to monitor the spatial distribution and/or the temporal evolution of an aerosol. In occupational hygiene, no standard recommend
22、s workers exposure assessment using optical particle counters. These instruments should instead be considered as permitting a complementary approach to the conventional filter-based gravimetric method. The estimated mass concentrations from OPC data are only indicative and can not be used for a dire
23、ct comparison with a legally enforced occupational exposure limit. An OPC method allows assessment of working place aerosol conditions including: almost instantaneous evaluation of particle concentration and size distribution; estimating concentration variations and mean concentration of aerosol par
24、ticles during a working shift period; sampling to constitute a particle sample for further analysis (when equipped with terminal filter). PD CEN/TR 16013-2:2010CEN/TR 16013-2:2010 (E) 6 1 Scope This Technical Report describes the principle underlying evaluation of one or more health related aerosol
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CENTR1601322010WORKPLACEEXPOSUREGUIDEFORTHEUSEOFDIRECTREADINGINSTRUMENTSFORAEROSOLMONITORINGPART2EVALUATIONOFAIRBORNEPARTICLECONCENTRATIONSUSINGOPTICAPDF

链接地址:http://www.mydoc123.com/p-592190.html