1、 ANSI/CEA Standard Mobile Electronics Cabling Standard ANSI/CEA-2015 May 2007 NOTICE Consumer Electronics Association (CEA) Standards, Bulletins and other technical publications are designed to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, faci
2、litating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such Standards, Bulletins and other technical publications shall not in any respect preclude any member or nonme
3、mber of CEA from manufacturing or selling products not conforming to such Standards, Bulletins or other technical publications, nor shall the existence of such Standards, Bulletins and other technical publications preclude their voluntary use by those other than CEA members, whether the standard is
4、to be used either domestically or internationally. Standards, Bulletins and other technical publications are adopted by CEA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, CEA does not assume any liability to any patent owner, nor does it assume any
5、 obligation whatever to parties adopting the Standard, Bulletin or other technical publication. This CEA Standard is considered to have International Standardization implication, but the International Electrotechnical Commission activity has not progressed to the point where a valid comparison betwe
6、en the CEA Standard and the IEC document can be made. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to det
7、ermine the applicability of regulatory limitations before its use. (Formulated under the cognizance of the CEAs R6 Mobile Electronics Committee.) Published by CONSUMER ELECTRONICS ASSOCIATION 2007 Technology Phone 800-854-7179; Fax 303-397-2740; Internet http:/; Email 2.2 Informative References The
8、 following references contain provisions that, through reference in this text, constitute informative provisions of this standard. At the time of publication, the edition indicated was valid. All standards are subject to revision, and parties to agreements based on this standard are encouraged to in
9、vestigate the possibility of applying the most recent edition of the standard indicated below. 2.2.1 Informative Reference List CEA-2006-A, Testing Phone 800-854-7179; Fax 303-397-2740; Internet http:/; Email National Electric Code: National Fire Protection Association, 1 Batterymarch Park, Quincy,
10、 MA, USA 02169-7471; Phone +1 617 770-3000; Internet http:/www.nfpa.org 2.3 Symbols and Abbreviations AWG American Wire Gauge IACS International Annealed Copper Standard 2.4 Compliance Notation As used in this document “shall” and “must” denote mandatory provisions of the standard. “Should” denotes
11、a provision that is recommended but not mandatory. “May” denotes a feature whose presence does not preclude compliance, and implementation of which is optional. “Optional” denotes items that may or may not be present in a compliant device. 3 Conductor Design Conductors shall be composed of multiple
12、strands of copper wire. Conductors shall comply with the size, resistivity and strand count requirements defined in Table 1. AWG gauges are defined in ASTM B 258, Standard Specification for Standard Nominal Diameters and Cross-Sectional Areas of AWG Sizes of Solid Round Wires Used as Electrical Cond
13、uctors, Rev. 02. 4Table 1: Size, Conductor Resistivity and Strand Count Requirements for CEA Wire Gauges Cross Sectional Area Gauge cmills NOM cmills MIN mm2NOM mm2MIN Minimum Strand Count for Entire Cable Minimum # of Groups Resistance per meter NOM (milliohms) Resistance per meter MAX (milliohms)
14、0000 AWG 211,565 198,934 107.2 100.8 3174 45 0.17 0.18 000 AWG 167,752 157,686 85.0 79.9 2517 45 0.22 0.23 00 AWG 133,017 125,123 67.4 63.4 1997 45 0.27 0.29 0 AWG 105,585 99,269 53.5 50.3 1584 18 0.35 0.37 1 AWG 83,678 78,744 42.4 39.9 1255 18 0.44 0.46 2 AWG 66,311 62,364 33.6 31.6 995 18 0.55 0.5
15、9 3 AWG 52,693 49,536 26.7 25.1 789 6 0.69 0.74 4 AWG 41,641 39,076 21.1 19.8 626 6 0.88 0.93 5 AWG 33,155 31,182 16.8 15.8 496 6 1.10 1.17 6 AWG 26,248 24,669 13.3 12.5 394 6 1.39 1.48 7 AWG 20,919 19,735 10.6 10.0 312 6 1.75 1.85 8 AWG 16,518 15,531 8.37 7.87 248 6 2.21 2.35 9 AWG 13,084 12,295 6.
16、63 6.23 196 6 2.79 2.97 10 AWG 10,380 9,749 5.26 4.94 156 6 3.52 3.74 11 AWG 8,229 7,736 4.17 3.92 123 6 4.44 4.72 12 AWG 6,532 6,137 3.31 3.11 98 6 5.59 5.95 13 AWG 5,190 4,874 2.63 2.47 78 6 7.03 7.49 14 AWG 4,104 3,868 2.08 1.96 62 6 8.89 9.44 15 AWG 3,256 3,059 1.65 1.55 49 6 11.21 11.94 16 AWG
17、2,585 2,427 1.31 1.23 39 1 14.12 15.04 17 AWG 2,052 1,934 1.04 0.98 31 1 17.79 18.88 18 AWG 1,624 1,527 0.823 0.774 24 1 22.48 23.90 19 AWG 1,288 1,211 0.653 0.614 19 1 28.33 30.13 20 AWG 1,024 963 0.519 0.488 15 1 35.65 37.91 54 Power Handling Capability The power handling capability of any cable i
18、s dependent on the material used to make the cable, and the size of the cable. The lower the resistivity of the conductive material used in the cable, the more power it can handle, all else being equal. Also, the larger the cross-sectional area of the cable the more power it can handle, all else bei
19、ng equal. CEA-2015 rates power cables and speaker cables differently. 4.1 Power Cables Power cables are rated in terms of the amplifiers with which they should be used. When amplifier power is measured in accordance with CEA-2006-A the amplifier power that is reported to consumers for a particular p
20、roduct is not equivalent to the power consumed by that product. Instead, it represents the power delivered to 4 ohm speakers. In order to convert this number to power consumed by the amplifier one needs to factor in the efficiency of the amplifier. For example, if an amplifier is rated as a 50 watt
21、per channel x 2 channel amplifier using CEA-2006-A, and the efficiency of the amplifier is 50 percent, then only 50 percent of the power supplied to the amplifier makes it to the speakers, and the total power consumed by the amplifier is 200 watts (50 watts per channel x 2 channels divided by 0.5).
22、So, in order to supply power to the CEA-2006-A-rated amplifier in this example, the power cables must be able to handle 200 watts of power. CEA-2015 assumes a standard efficiency of 50 percent for all amplifiers, which is typical performance for a class AB amplifier. While some amplifiers may be mor
23、e efficient than this, it is believed that a 50 percent efficiency assumption for all amplifiers will ensure that the CEA-2015-rated capacity of power cables will be equal to or greater than the power consumption of amplifiers if their output power is rated in accordance with CEA-2006-A. Once the am
24、ount of power that needs to be delivered to the amplifier by the cable is known the next step is to determine the current flowing through the cable. Current equals power divided by voltage. We know the power, and we also know that the voltage supplied to the amplifier is coming from a car battery. F
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CEA20152007MOBILEELECTRONICSCABLINGSTANDARD 移动 电子 布线 标准 PDF

链接地址:http://www.mydoc123.com/p-591442.html