CAN CGSB-12 4-M91-1991 Heat Absorbing Glass.pdf
《CAN CGSB-12 4-M91-1991 Heat Absorbing Glass.pdf》由会员分享,可在线阅读,更多相关《CAN CGSB-12 4-M91-1991 Heat Absorbing Glass.pdf(21页珍藏版)》请在麦多课文档分享上搜索。
1、CGSB CAN/.CGSB- 12.4-ML tt 1874650 0001193 T71 CANICGSB-12.4-M91 SupersededRemplace NATIONAL NORME STANDARD N AT1 O NA LE CAN/CGSB-12.4-M76 OF CANADA DU CANADA I 1 Heat Verre Absorbing athermane Glass * Canadian General Standards Board ss Office des normes gnrales du Canada O this surface is not ill
2、uminated by direct sunlight so its brightness is very low. Thus very little radiation enters the radiometer by reflection compared with the solar radiation that comes through the glass. The long-wave radiation emitted by the glass is excluded from the radiometer by a quariz window at the entrance to
3、 the radiometer tube. rflchis proviennent de la face intrieure peinte en noir de cet abat-jour; cette face prsente une luminosit trs faible du fait quelle nest pas directement claire par la lumire du soleil. Ainsi, une trs faible quantit de rayons rflchis pntrent dans le radiomtre comparativement au
4、x rayons solaires qui traversent le verre. Les rayons grandes ondes mis par le verre sont carts du radiomtre au moyen dune fentre de quae place lentre du tube du radiomtre. Radiometer in position for transmission test Radiomtre install pour lessai de transmission Radiometer in position for reflectio
5、n test Radiomtre install FIGURE Al Arrangement for Transmission and Reflection Test on Glazing Unit Montage pour lessai de transmission et de rflexion duo panneau de verre A2.4 The procedure for determining the reflection factor is similar: La mthode de calcul du facteur de rflexion est semblable: A
6、2.4.1. The radiometer is aimed at the sun and the voltage, el, generated by the thermopile is measured. A2.4.2 The glazing unit is placed behind the radiometer and positioned so that the direct rays from the sun have the desired angle of incidence at the glass surface. The radiometer is then aimed a
7、t the image of the sun produced by the glazing unit. The thermopile output voltage, e3, is measured. A2.4.3 The solar reflection factor for the glazing unit is simply p = edel. Pointer le radiomtre vers le soleil et mesurer la tension, el, produite par la thermopile. Placer le panneau derrire le rad
8、iomtre en lorientant de faon que les rayons mis directement par le soleil aient langle dincidence voulu sur la surface du verre. Pointer ensuite le radiomtre vers le reflet du soleil mis par le panneau de verre. Mesurer la tension de sortie, e3, de la thermopile. Le facteur de rflexion de la lumire
9、du soleil pour ce panneau est simplement le suivant: p = edel. O A2.4.4 In this case it is important that the brightness of the background seen through the window by the radiometer Dans ce casci, il est important que la luminosit du fond, perue travers la fentre par le radiomtre, soit trs faible par
10、 A2 CAN/CGSB-I 2.4-M91 CGSB CANICGSB- 12.4-Pl91 Xf 1874b50 OOOLZOb 45T be very low compared with the brightness of the suns image. The black-painted shade behind the unit shown in Figure Al ensures that this is the case. rapport celle du reflet du soleil. Voil ce quassure labat-jour peint en noir il
11、lustr la figure Al. A3. THERMAL CONDUCTANCE OF ME INTERPANE CONDUCTIVIT MERMIQUE DE LA LAME DAIR ENTRE AIRSPACE DEUX VITRES A3.1 Heat is transferred across an airspace in a window by two quite separate processes: by thermal radiation and by conduction, or a combination of conduction and convection.
12、The rate of heat transfer by each process is dependent on the difference between the temperatures of surfaces that bound the space. The ratio of the heat flux to the temperature difference is the thermal conductance of the airspace. A3.2 The conductance associated with the radiant heat transfer depe
13、nds on the emissivity of the enclosing surfaces as well as on the mean temperature. The thin film of metal that is applied to the surface of the glass in a reflective glazing unit generally reduces the emissivity of the surface and hence reduces the conductance of the airspace. The conductance of th
14、e airspace in this type of unit can be determined experimentally using a guarded hot plate apparatus of the type normally used to determine the thermal conductivity of materials. A sample is made by taking two sheets of glass of the same types that are used in the glazing unit, and separating them b
15、y about 6 mm by using small pieces of flat glass ai each corner. The thickness of the airspace is then the same as the thickness of the glass spacer pieces, which can be measured accurately with a micrometer. The two sheets of glass can be held together by a strip of adhesive tape applied all around
16、 the perimeter. This also completes the enclosure of the airspace. A pair of identical samples are placed in a guarded hot plate and their overall thermal resistance is measured in the normal way. The resistance of the airspace is obtained by subtracting the thermal resistance of the two sheets of g
17、lass from the measured total resistance. The conductance of the airspace is just the reciprocal of its thermal resistance. The conductance obtained in this way is for the particular thickness and mean temperature used for the test. Values for other thicknesses and mean temperatures can be deduced fr
18、om this value. A3.3 O A3.4 La chaleur traverse la lame dair qui spare deux vitres dune fentre de deux faons tout fait diffrentes: par rayonnement thermique et par conduction, ou par une combinaison de conduction et de convection. Le taux de transfert de la chaleur selon chaque mthode est fonction de
19、 la diffrence de temprature entre les deux surfaces qui limitent la lame. Le rapport du flux de chaleur la diffrence de temprature reprsente la conductivit thermique de la lame dair. La conductivit associe au transfert de la chaleur rayonnante est fonction de Imissivit des surfaces qui retiennent la
20、ir, ainsi que de la temprature moyenne. La mince couche de mtal qui est applique la surface du verre dune vitre rflchissante rduit en gnral Imissivit de la surface et, par consquent, rduit la conductivit de la lame dair. La conductivit de la lame dair de ce genre de vitrage peut tre dtermine exprime
21、ntalement laide dune plaque chauffante grillage du modle habituellement utilis pour dterminer la conductivit thermique des matriaux. Lchantillon se compose de deux vitres du mme type que celui des vitres constituant le panneau, spares denviron 6 mm par de petits fragments de verre plat placs chaque
22、coin. Lpaisseur de la lame dair est alors la mme que celle des fragments de verre qui servent de cales despacement et peut tre mesure avec prcision au moyen dun micromtre. Les deux vitres peuvent tre retenues ensemble par un ruban adhsif appliqu sur leur pourtour. Ce ruban sert galement enfermer la
23、lame dair. Placer deux chantillons identiques sur une plaque chauffante grillage et mesurer leur rsistance thermique totale de la manire habituelle. Calculer la rsistance de la lame dair en soustrayant la rsistance thermique des deux vitres de la rsistance totale. La conductivit de la lame dair est
24、inversement proportionnelle sa rsistance thermique. La conductivit ainsi obtenue vaut pour lpaisseur et la temprature moyenne utilises pour le prsent essai. Les valeurs applicables dautres paisseurs et tempratures moyennes peuvent tre tablies partir de cette valeur. A3.5 The conductance due to heat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CANCGSB124M911991HEATABSORBINGGLASSPDF