BS ISO 4795-1997 Laboratory glassware - Glass for thermometer bulbs《实验室玻璃器皿 温度计球头玻璃》.pdf
《BS ISO 4795-1997 Laboratory glassware - Glass for thermometer bulbs《实验室玻璃器皿 温度计球头玻璃》.pdf》由会员分享,可在线阅读,更多相关《BS ISO 4795-1997 Laboratory glassware - Glass for thermometer bulbs《实验室玻璃器皿 温度计球头玻璃》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS ISO 4795:1996 Laboratory glassware Glass for thermometer bulbs ICS 17.200.20; 71.040.20BSISO4795:1996 This British Standard, having been prepared under the directionof the Sector Board for Materials and Chemicals, was published under the authority ofthe Standards Board and comesi
2、ntoeffect on 15 April 1997 BSI 09-1999 ISBN 0 580 27252 4 National foreword This British Standard reproduces verbatim ISO 4795:1996 and implements it as the UK national standard. The UK participation in its preparation was entrusted by Technical Committee LBI/36, Laboratory glassware and related app
3、aratus, to Subcommittee LBI/36/3, Thermometers, which has the responsibility to: aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UKinterests informed; monitor related internat
4、ional and European developments and promulgate them in the UK. A list of organizations represented on this subcommittee can be obtained on request. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Stand
5、ards Catalogue under the section entitled “International Standards Correspondence Index”, or using the “Find” facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for
6、their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, theISO title page, page ii, pages 1 to 4 and a back cover. This standard has been up
7、dated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. Amendments issued since publication Amd. No. Date CommentsBSISO4795:1996 BSI 09-1999 i Contents Page National foreword Inside front cover Foreword ii 1 Scope
8、1 2 Normative references 1 3 Definitions 1 4 Maximum temperature of use 1 5 Requirements 1 6 Marking 1 Annex A (normative) Determination of the average zero-point depression 2 Annex B (informative) Stabilization test 3 Annex C (informative) Zero-point depression of some types of thermometric glass 3
9、 Annex D (informative) Type of glass and identification 3 Table D.1 Certified thermometric glass 4ii blankBSISO4795:1996 ii BSI 09-1999 Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing
10、International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaiso
11、n with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication
12、as an International Standard requires approval by at least 75 % of the member bodies casting a vote. This International Standard ISO 4795 has been prepared by Technical Committee ISO/TC 48, Laboratory glassware and related apparatus, Subcommittee SC 3, Thermometers. Annex A forms an integral part of
13、 this International Standard. Annex B, Annex C and Annex D are for information only. Descriptors: Laboratory equipment, laboratory glassware, thermometers, tanks (containers), specifications, materials specifications, marking.BSISO4795:1996 BSI 09-1999 1 1 Scope This International Standard specifies
14、 the physical and chemical characteristics and the marking of thermometric glass and the test methods to be used for the selection of glass for the manufacture of the bulbs of liquid-in-glass thermometers. It is not applicable to the glass used in parts of the thermometer other than the bulb (e.g. t
15、he stem). However, the glass used for the other parts can be identical to that used for the bulb. The coefficient of linear thermal expansion of the bulb glass should not differ from that of the glass intended for the stem by more than 0,2 10 6K 1 . 2 Normative references The following standards con
16、tain provisions which, through references in this text, constitute provisions of this International Standard. At the time of publication, the editions indicated were valid. All standards are subject to revision, and parties to agreements based on this International Standard are encouraged to investi
17、gate the possibility of applying the most recent editions of the standards indicated below. Members of IEC and ISO maintain registers of currently valid International Standards. ISO 719:1985, Glass Hydrolytic resistance of glass grains at 98 C Method of test and classification. ISO 7884-7:1987, Glas
18、s Viscosity and viscometric fixed points Part 7: Determination of annealing point and strain point by beam bending. 3 Definitions For the purposes of this International Standard, the following definitions apply. 3.1 strain point, F f4 the temperature determined in accordance with ISO7884-7 NOTEBy th
19、e beam-bending method, the viscosity of glass at the strain point may be evaluated as 10 14,7dPas. 3.2 zero-point correction, K correction of the thermometer at 0 C: K = 0 C t ind where t indis the temperature indicated 3.3 zero-point depression change of the zero-point correction after heating and
20、fast cooling of the thermometer 4 Maximum temperature of use The maximum temperature recommended for use shall not exceed (F f4 130) C, where F f4is the strain point determined in accordance with the method given in ISO 7884-7. 5 Requirements 5.1 Stability The indication at 0 C of a suitable test th
21、ermometer having a bulb made of the glass under consideration shall not change by more than 2 C after exposure to the maximum temperature recommended for use (see clause 4) for 500 h. This stability requirement can be determined in accordance with Annex B. 5.2 Zero-point depression When tested in ac
22、cordance with the procedure given in Annex A, a thermometer having a bulb made of the glass under consideration shall have an average zero-point depression not exceeding 0,05 C for “normal glass” or 0,03 C for borosilicate glass. NOTEThe zero-point depression of some types of thermometric glass is g
23、iven in Annex C. 5.3 Chemical resistance When tested according to the procedure and classification given in ISO 719, the glass shall comply with the requirements of class HGB 3 or better. 6 Marking 6.1 Thermometric glass complying with this International Standard shall be identified according to eit
24、her of the schemes given in 6.2 and 6.3. 6.2 The manufacturer of the thermometric glass shall incorporate an identification stripe or stripes in accordance with the approved list shown in Table D.1 (see Annex D). 6.3 The manufacturer of the thermometer shall mark it with an identification alphanumer
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSISO47951997LABORATORYGLASSWAREGLASSFORTHERMOMETERBULBS 实验室 玻璃器皿 温度计 玻璃 PDF

链接地址:http://www.mydoc123.com/p-587388.html