BS ISO 12771-1997 Plastics laboratory ware - Disposable serological pipettes《实验室塑料制品器皿 可处理的血清移液管》.pdf
《BS ISO 12771-1997 Plastics laboratory ware - Disposable serological pipettes《实验室塑料制品器皿 可处理的血清移液管》.pdf》由会员分享,可在线阅读,更多相关《BS ISO 12771-1997 Plastics laboratory ware - Disposable serological pipettes《实验室塑料制品器皿 可处理的血清移液管》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS ISO 12771:1997 Plastics Laboratory Ware Disposable serological pipettes ICS 11.100; 71.040.20BSISO12771:1997 This British Standard, having been prepared under the directionof the Sector Board forMaterials and Chemicals, waspublished under the authorityof the Standards Boardand co
2、mes into effect on 15 September 1997 BSI 09-1999 ISBN 0 580 28410 7 National foreword This British Standard reproduces verbatim ISO 12771:1997 and implements it as the UK national standard. The UK participation in its preparation was entrusted by Technical Committee LBI/36, Laboratory glassware and
3、related apparatus, to Subcommittee LBI/36/1, Volumetric instruments, which has the responsibility to: aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; mo
4、nitor related international and European developments and promulgate them in the UK. A list of organizations represented on this subcommittee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this
5、 document may be found in the BSI Standards Catalogue under the section entitled “International Standards Correspondence Index”, or using the “Find” facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions of a contract. Users of
6、 British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, the ISO title page, pages ii to iv, pages 1 t
7、o 4 and abackcover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. Amendments issued since publication Amd. No. Date CommentsBSISO12771:1997 BSI 09-1999 i Contents Page National fo
8、reword Inside front cover Foreword iii Text of ISO 12771 1ii blankBSISO12771:1997 ii BSI 09-1999 Contents Page Foreword iii 1 Scope 1 2 Normative references 1 3 Definitions 1 4 Basis of adjustment 1 5 Dimensions and delivery times 1 6 Construction 1 7 Volumetric performance 2 8 Definition of capacit
9、y 2 9 Determination of accuracy and repeatability 3 10 Marking 3 Annex A (informative) Bibliography 4 Table 1 Capacity, subdivision, dimensions and delivery times 2 Table 2 Dimensions of optional suction tubes 2 Descriptors: Laboratory equipment, disposable equipment, plastics products, pipettes, sp
10、ecifications, dimensions, capacity, marking, colour codes.BSISO12771:1997 BSI 09-1999 iii Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried ou
11、t through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO co
12、llaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval
13、 by at least75% of the member bodies casting a vote. International Standard ISO12771 was prepared by Technical Committee ISO/TC48, Laboratory glassware and related apparatus, Subcommittee SC1, Volumetric instruments. Annex A of this International Standard is for information only.iv blankBSISO12771:1
14、997 BSI 09-1999 1 1 Scope This International Standard specifies requirements for disposable plastics serological pipettes, gauged to deliver, suitable for general laboratory purposes. 2 Normative references The following standards contain provisions which, through references in this text, constitute
15、 provisions of this International Standard. At the time of publication, the editions indicated were valid. All standards are subject to revision, and parties to agreements based on this International Standard are encouraged to investigate the possibility of applying the most recent editions of the s
16、tandards indicated below. Members of IEC and ISO maintain registers of currently valid International Standards. ISO 1043-1:1987, Plastics Symbols Part1:Basic polymers and their special characteristics. ISO 1769:1975, Laboratory glassware Pipettes Colour coding. ISO 8417:, Laboratory volumetric instr
17、uments Principles of design and construction of disposable volumetric articles 1) . 3 Definitions For the purposes of this International Standard, the following definitions apply. 3.1 disposable adjective used to describe serological pipettes which are intended to be used once only and then discarde
18、d NOTESuch pipettes will only be expected to provide their specified performance during the original operation. 3.2 accuracy (of a pipette) closeness of agreement between the nominal volume and the true volume, obtained by applying the test procedure specified in clause9.1. It is quantified by the c
19、apacity deviation 3.3 repeatability (of a number of pipettes) closeness of agreement between the individual volumes obtained by applying the test procedure specified in9.2 NOTE 1Definitions and terms are in agreement with the “International Vocabulary of Basic and General Terms in Metrology”. See IS
20、O3534-1 for details. NOTE 2The definitions for accuracy and repeatability apply only in cases where the distributions are Gaussian. 4 Basis of adjustment 4.1 Unit of volume The unit of volume is the cubic centimetre (cm 3 ), for which the name millilitre (ml) may be used. NOTEThe term millilitre (ml
21、) is commonly used as a special name for the cubic centimetre (cm 3 ), in accordance with the International System of Units (SI). 4.2 Reference temperature The reference temperature, i.e.the temperature at which the pipette is intended to deliver its nominal volume (nominal capacity), is20 C. When t
22、he pipette is required for use in a country which has adopted a reference temperature of27 C (the alternative specified in ISO8417 for tropicaluse), this figure shall be substituted for20 C. 4.3 Adjustment The pipettes shall be adjusted to deliver the required volume (i.e.the nominal volume or a par
23、tof it) with the last drop to be blown out. 5 Dimensions and delivery times The dimensions and delivery times shall be as shown in Table 1. The delivery time shall be determined with the pipette unplugged, and with distilled water at a temperature of20 C. 6 Construction 6.1 Material The pipettes sha
24、ll be made of translucent plastics material of chemical and physical properties suitable for their intended use. The plastic material or its symbol in accordance with ISO1043-1 shall be marked on each pipettes. 6.2 Graduation and figuring The pipettes shall be provided with a graduation in accordanc
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSISO127711997PLASTICSLABORATORYWAREDISPOSABLESEROLOGICALPIPETTES 实验室 塑料制品 器皿 处理 血清 移液管 PDF

链接地址:http://www.mydoc123.com/p-583966.html