BS EN 62718-2016 Railway applications Rolling stock DC supplied electronic ballasts for lighting fluorescent lamps《轨道交通 机车车辆 照明荧光灯用直流电子镇流器》.pdf
《BS EN 62718-2016 Railway applications Rolling stock DC supplied electronic ballasts for lighting fluorescent lamps《轨道交通 机车车辆 照明荧光灯用直流电子镇流器》.pdf》由会员分享,可在线阅读,更多相关《BS EN 62718-2016 Railway applications Rolling stock DC supplied electronic ballasts for lighting fluorescent lamps《轨道交通 机车车辆 照明荧光灯用直流电子镇流器》.pdf(46页珍藏版)》请在麦多课文档分享上搜索。
1、BS EN 62718:2016Railway applications Rolling stock DC supplied electronic ballasts for lighting fluorescent lamps * - Sections 8.2.3.1 and 9.3.4.1: the specified Level (0,7 mA) of leakage current in EN 50311:2003 is omitted, instead of it a reference to the standard (IEC 60598-1:2008, Section 10.3)
2、is noted; - Section 9.3.2.8: Table 3 - Dielectric test voltage values are referenced to IEC 62497-1, this cause an extension of the nominal voltage levels; - Section 9.3.4.1: the values of R and C in Figure 3 (EN 50311:2003 R = 2 000 g525 100 g525 C = 112 nF 6 nF) are omitted; - new Annex A (informa
3、tive): Distance between lamp an metallic support (before it was normative in Section 8.2.4.4 of EN 50311:2003); - Annex H from EN 50311:2003 is omitted. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not
4、be held responsible for identifying any or all such patent rights. Endorsement notice The text of the International Standard IEC 62718:2013 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following notes have to be added for the
5、 standards indicated: IEC 60068-1:1988 NOTE Harmonized as EN 60068-1:1994 1)(not modified). IEC 60081 NOTE Harmonized as EN 60081. IEC 60901:1996 NOTE Harmonized as EN 60901:1996 (not modified). IEC 60927 NOTE Harmonized as EN 60927. IEC 61347-2-7:2011 NOTE Harmonized as EN 61347-2-7:2012 (not modif
6、ied). CISPR 15:2005 NOTE Harmonized as EN 55015:2006 2)(not modified). CISPR 15:2005/A1:2006 NOTE Harmonized as EN 55015:2006/A1:2007 2)(not modified). 1)Superseded by EN 60068-1:2014 (IEC 60068-1:2013): DOW = 2016-11-11. 2)Superseded by EN 55015:2013 (CISPR 15:2013 + IS1:2013 + IS2:2013): DOW= 2016
7、-06-12. BS EN 62718:2016iiEN 62718:2016 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For date
8、d references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. NOTE 2 Up-to-dat
9、e information on the latest versions of the European Standards listed in this annex is available here: www.cenelec.eu Publication Year Title EN/HD Year IEC 60068-2-1 2007 Environmental testing - Part 2-1: Tests - Test A: Cold EN 60068-2-1 2007 IEC 60068-2-2 2007 Environmental testing - Part 2-2: Tes
10、ts - Test B: Dry heat EN 60068-2-2 2007 IEC 60068-2-30 2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) EN 60068-2-30 2005 IEC 60077-1 (mod) 1999 Railway applications - Electric equipment for rolling stock - Part 1: General service conditions and general
11、 rules EN 60077-1 2002 IEC 60417-DB - Graphical symbols for use on equipment - - IEC 60529 1989 Degrees of protection provided by enclosures (IP Code) EN 60529 +corr. May 1991 1993 IEC 60571 2012 Railway applications - Electronic equipment used on rolling stock EN 50155 + corr. May + AC 2007 2010 20
12、12 IEC 60598-1 (mod) 2008 Luminaires - Part 1: General requirements and tests EN 60598-1 A11 2008 3)2009 3)IEC 60929 - AC and/or DC-supplied electronic control gear for tubular fluorescent lamps - Performance requirements EN 60929 - IEC 61140 - Protection against electric shock - Common aspects for
13、installation and equipment EN 61140 - IEC 61347-1 (mod) 2007 Lamp controlgear - Part 1: General and safety requirements EN 61347-1 2008 4)IEC 61347-2-3 - Lamp controlgear - Part 2-3: Particular requirements for a.c. and/or d.c. supplied electronic control gear for fluorescent lamps EN 61347-2-3 - 3)
14、Superseded by EN 60598-1:2015 (IEC 60598-1:2014): DOW = 2017-10-20. 4)Superseded by EN 61347-1:2015 (IEC 61347-1:2015): DOW = 2018-03-26. BS EN 62718:2016iiiEN 62718:2016 Publication Year Title EN/HD Year IEC 61373 - Railway applications - Rolling stock equipment - Shock and vibration tests EN 61373
15、 - IEC 62236-3-2 2008 Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus EN 50121-3-2 2006 IEC 62497-1 - Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment
16、 EN 50124-1 - IEC 62498-1 - Railway applications - Environmental conditions for equipment - Part 1: Equipment on board rolling stock EN 50125-1 - BS EN 62718:2016iv 2 62718 IEC:2013 CONTENTS FOREWORD . 4 INTRODUCTION . 6 1 Scope . 7 2 Normative references 7 3 Terms and definitions . 8 3.1 General te
17、rms 8 3.2 Lamps and characteristics . 9 4 Classification 10 5 Characteristics 10 5.1 Rated voltages. 10 5.2 Overvoltages . 10 5.3 Type of fluorescent lamps 10 6 Product information . 11 6.1 Nature of information . 11 6.1.1 General . 11 6.1.2 Identification 11 6.1.3 Characteristics . 11 6.1.4 Other c
18、haracteristics and information for installation. 11 6.2 Marking . 11 6.3 Instructions for storage, installation, operation and maintenance 12 7 Normal service conditions . 12 8 Constructional and performance requirements 12 8.1 Constructional requirements 12 8.1.1 General . 12 8.1.2 Dimensions and w
19、iring diagram 12 8.1.3 Terminals 12 8.1.4 Provisions for repair . 12 8.1.5 Clearance and creepage distances . 13 8.1.6 Protection 13 8.1.7 Inrush current 13 8.2 Performance requirements . 13 8.2.1 Electronic ballast parameters in accordance with lamps characteristics . 13 8.2.2 Exceptional condition
20、s of use . 14 8.2.3 Electronic ballast design requirements . 15 8.2.4 Installation requirements 16 8.3 Safety requirements . 17 9 Tests 17 9.1 Test conditions 17 9.1.1 Environmental conditions . 17 9.1.2 Other conditions 18 9.2 Kinds of tests . 18 9.2.1 Type tests 18 9.2.2 Routine tests . 19 9.2.3 I
21、nvestigatory tests 20 9.3 Verification of constructional and performance requirements 20 BS EN 62718:201662718 IEC:2013 3 9.3.1 General . 20 9.3.2 Sequence 1 . 20 9.3.3 Sequence 2 . 22 9.3.4 Sequence 3 . 24 9.3.5 Sequence 4 . 25 9.3.6 Sequence 5 . 27 Annex A (informative) Distance between lamp and m
22、etallic support 29 Annex B (informative) Electronic ballast for lamps up to 40 W (case 1) . 30 Annex C (informative) Electronic ballast for lamps up to 40 W (case 2) . 31 Annex D (informative) Electronic ballast for lamps up to 15 W 32 Annex E (informative) Electronic ballast for lamps up to 20 W. 3
23、3 Annex F (informative) Electronic ballast for lamps up to 10 W . 34 Annex G (informative) Basic schematic diagrams . 35 Bibliography 38 Figure 1 Test circuit . 22 Figure 2 Current limiting curve 23 Figure 3 Circuit for leakage current measurement . 24 Figure 4 Circuit for test B: Cathode deactivate
24、d (rectifying effect) . 26 Figure B.1 Overall dimensions for electronic ballast 30 Figure C.1 Overall dimensions for electronic ballast 31 Figure D.1 Overall dimensions for electronic ballast 32 Figure E.1 Overall dimensions for electronic ballast 33 Figure F.1 Overall dimensions for electronic ball
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN627182016RAILWAYAPPLICATIONSROLLINGSTOCKDCSUPPLIEDELECTRONICBALLASTSFORLIGHTINGFLUORESCENTLAMPS 轨道交通

链接地址:http://www.mydoc123.com/p-578662.html