BS EN 60079-29-2-2015 Explosive atmospheres Gas detectors Selection installation use and maintenance of detectors for flammable gases and oxygen《爆炸性气体环境 第29-2部分 气体探测器 易燃气体和氧用探测器的选择.pdf
《BS EN 60079-29-2-2015 Explosive atmospheres Gas detectors Selection installation use and maintenance of detectors for flammable gases and oxygen《爆炸性气体环境 第29-2部分 气体探测器 易燃气体和氧用探测器的选择.pdf》由会员分享,可在线阅读,更多相关《BS EN 60079-29-2-2015 Explosive atmospheres Gas detectors Selection installation use and maintenance of detectors for flammable gases and oxygen《爆炸性气体环境 第29-2部分 气体探测器 易燃气体和氧用探测器的选择.pdf(120页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationExplosive atmospheresPart 29-2: Gas detectors Selection, installation, use and maintenance of detectors for flammable gases and oxygenBS EN 60079-29-2:2015National forewordThis British Standard is the UK implementation of EN 60079-29-2:2015. It isidentical to IEC 60079-29-2:
2、2015. It supersedes BS EN 60079-29-2:2007which is withdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee EXL/31, Equipment for explosive atmospheres.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does n
3、ot purport to include all the necessary provisions ofa contract. Users are responsible for its correct application. The British Standards Institution 2015.Published by BSI Standards Limited 2015ISBN 978 0 580 79818 4ICS 13.320; 29.260.20Compliance with a British Standard cannot confer immunity froml
4、egal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 31 May 2015.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN 60079-29-2:2015EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 60079-29-2 M
5、ay 2015 ICS 29.260.20 Supersedes EN 60079-29-2:2007 English Version Explosive atmospheres - Part 29-2: Gas detectors - Selection, installation, use and maintenance of detectors for flammable gases and oxygen (IEC 60079-29-2:2015) Atmosphres explosives - Partie 29-2: Dtecteurs de gaz - Slection, inst
6、allation, utilisation et maintenance des dtecteurs de gaz inflammables et doxygne (IEC 60079-29-2:2015) Explosionsfhige Atmosphre - Teil 29-2: Gasmessgerte - Auswahl, Installation, Einsatz und Wartung von Gerten fr die Messung von brennbaren Gasen und Sauerstoff (IEC 60079-29-2:2015) This European S
7、tandard was approved by CENELEC on 2015-04-20. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references conc
8、erning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC m
9、ember into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Repu
10、blic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardizati
11、on Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2015 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. EN 60079-29-2:201
12、5 E BS EN 60079-29-2:2015EN 60079-29-2:2015 - 2 - Foreword The text of document 31/1169/FDIS, future edition 2 of IEC 60079-29-2, prepared by IEC TC 31, Equipment for explosive atmospheres, was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 60079-29-2:2015. The following da
13、tes are fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2016-01-20 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2018-04-20 This document s
14、upersedes EN 60079-29-2:2007. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. Endorsement notice The text of the International Standar
15、d IEC 60079-29-2:2015 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following notes have to be added for the standards indicated: IEC 60079-14 NOTE Harmonized as EN 60079-14. IEC 60079-20-1 NOTE Harmonized as EN 60079-20-1. IE
16、C 61326-1 NOTE Harmonized as EN 61326-1. IEC 60079-29-3 NOTE Harmonized as EN 60079-29-3. BS EN 60079-29-2:2015- 3 - EN 60079-29-2:2015 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following documents, in whole or in part,
17、 are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE 1 When an International Publication has been mo
18、dified by common modifications, indicated by (mod), the relevant EN/HD applies. NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here: www.cenelec.eu. Publication Year Title EN/HD Year IEC 60079-0 - Explosive atmospheres - Part 0: Equip
19、ment - General requirements EN 60079-0 - - - +A11 - IEC 60079-10-1 2008 Explosive atmospheres - Part 10-1: Classification of areas - Explosive gas atmospheres EN 60079-10-1 2009 IEC 60079-10-2 - Explosive atmospheres - Part 10-2: Classification of areas - Combustible dust atmospheres EN 60079-10-2 -
20、 IEC 60079-13 - Explosive atmospheres - Part 13: Equipment protection by pressurized room “p“ EN 60079-13 - IEC 60079-17 - Explosive atmospheres - Part 17: Electrical installations inspection and maintenance EN 60079-17 - IEC 60079-19 - Explosive atmospheres - Part 19: Equipment repair, overhaul and
21、 reclamation EN 60079-19 - IEC 60079-29-1 (mod) 2007 Explosive atmospheres - Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases EN 60079-29-1 2007 IEC 60079-29-4 - Explosive atmospheres - Part 29-4: Gas detectors - Performance requirements of open path detectors for
22、 flammable gases EN 60079-29-4 - IEC 61285 - Industrial-process control - Safety of analyzer houses EN 61285 - BS EN 60079-29-2:2015 2 IEC 60079-29-2:2015 IEC 2015 CONTENTS FOREWORD . 8 INTRODUCTION . 11 1 Scope 13 2 Normative references 14 3 Terms and definitions 14 3.1 Gas properties and other phy
23、sics 14 3.2 Types of equipment 16 3.3 Sensors and detectors 18 3.4 Supply of gas to instruments . 19 3.5 Signals and alarms . 19 3.6 Times, checks and equipment behaviour . 20 3.7 Terms exclusive to open path equipment 21 4 Basic information on the properties, behaviour, gases and vapours, and speci
24、fic applications of gas detection . 23 4.1 Detecting gases and vapours 23 4.1.1 General . 23 4.1.2 Safety when monitoring for flammable gases where personnel could be present 24 4.2 Some common properties of gases and vapours . 25 4.3 The differences between detecting gases and vapours . 26 4.3.1 Ge
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN600792922015EXPLOSIVEATMOSPHERESGASDETECTORSSELECTIONINSTALLATIONUSEANDMAINTENANCEOFDETECTORSFORFLAMMABLEGASESANDOXYGEN

链接地址:http://www.mydoc123.com/p-575268.html