1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationPower transformersPart 2: Temperature rise for liquid-immersed transformersBS EN 60076-2:2011National forewordThis British Standard is the UK implementation of EN 60076-2:2011. I
2、t is identical to IEC 60076-2:2011. It supersedes BS EN 60076-2:1997 which The UK participation in its preparation was entrusted to Technical Committee PEL/14, Power transformers.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does n
3、ot purport to include all the necessary provisions of a contract. Users are responsible for its correct application. BSI 2011ISBN 978 0 580 60092 0 ICS 29.180Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of th
4、e Standards Policy and Strategy Committee on 31 May 2011.Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 60076-2:2011will be withdrawn 30 March 2014.EUROPEAN STANDARD EN 60076-2 NORME EUROPENNE EUROPISCHE NORM April 2011 CENELEC European Committee for Electrotechn
5、ical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 6007
6、6-2:2011 E ICS 29.180 Supersedes EN 60076-2:1997English version Power transformers - Part 2: Temperature rise for liquid-immersed transformers (IEC 60076-2:2011) Transformateurs de puissance - Partie 2: Echauffement des transformateurs immergs dans le liquide (CEI 60076-2:2011) Leistungstransformato
7、ren - Teil 2: bertemperaturen fr flssigkeitsgefllte Transformatoren (IEC 60076-2:2011) This European Standard was approved by CENELEC on 2011-03-30. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the stat
8、us of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German).
9、 A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cr
10、oatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 60076-2:2011
11、EN 60076-2:2011 - 2 - Foreword The text of document 14/669/FDIS, future edition 3 of IEC 60076-2, prepared by IEC TC 14, Power transformers, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60076-2 on 2011-03-30. This European Standard supersedes EN 60076-2:1997. EN 6
12、0076-2:2011 includes the following significant technical changes with respect to EN 60076-2:1997: the standard is applicable only to liquid immersed transformers; the winding hot-spot temperature rise limit was introduced among the prescriptions; the modalities for the temperature rise test were imp
13、roved in relation to the new thermal requirements; five informative annexes were added in order to facilitate the standard application. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and CENELEC shall not be held responsible
14、for identifying any or all such patent rights. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2011-12-30 latest date by which the national standards conflicting with the EN h
15、ave to be withdrawn (dow) 2014-03-30 Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 60076-2:2011 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following notes have to be add
16、ed for the standards indicated: 2 IEC 60296:2003 NOTE Harmonized as EN 60296:2004 (not modified). 3 IEC 60567:2005 NOTE Harmonized as EN 60567:2005 (not modified). 4 IEC 60599:1999 NOTE Harmonized as EN 60599:1999 (not modified). 5 IEC 60836:2005 NOTE Harmonized as EN 60836:2005 (not modified). 6 IE
17、C 61099:2010 NOTE Harmonized as EN 61099:2010 (not modified). _ BS EN 60076-2:2011- 3 - EN 60076-2:2011 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following referenced documents are indispensable for the application of t
18、his document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD appli
19、es. Publication Year Title EN/HD Year IEC 60076-1 (mod) - Power transformers - Part 1: General EN 60076-1 - IEC 60076-8 1997 Power transformers - Part 8: Application guide - - IEC 60085 2007 Electrical insulation - Thermal evaluation and designation EN 60085 2008 IEC 61181 2007 Mineral oil-filled el
20、ectrical equipment - Application of dissolved gas analysis (DGA) to factory tests on electrical equipment EN 61181 2007 IEC Guide 115 2007 Application of uncertainty of measurement to conformity assessment activities in the electrotechnical sector - - BS EN 60076-2:2011 2 60076-2 IEC:2011 CONTENTS 1
21、 Scope . . 6 2 Normative references . 6 3 Terms and definitions . 6 4 Cooling methods . 8 4.1 Identification symbols . 8 4.2 Transformers with alternative cooling methods . . 9 5 Normal cooling conditions. 9 5.1 Air-cooled transformers 9 5.2 Water-cooled transformers 10 6 Temperature rise limits . 1
22、0 6.1 General . . 10 6.2 Temperature rise limits at rated power 10 6.3 Modified requirements for special cooling conditions 12 6.3.1 General . 12 6.3.2 Air-cooled transformers 12 6.3.3 Water-cooled transformers . . 13 6.4 Temperature rise during a specified load cycle 13 7 Temperature rise tests 13
23、7.1 General . . 13 7.2 Temperature of the cooling media . 13 7.2.1 Ambient temperature . . 13 7.2.2 Water temperature . 14 7.3 Test methods for temperature rise determination . 14 7.3.1 General . 14 7.3.2 Test by short-circuit method for two winding transformers. . 14 7.3.3 Test modification for par
24、ticular transformers . 15 7.4 Determination of liquid temperatures . 16 7.4.1 Top-liquid temperature . 16 7.4.2 Bottom and average liquid temperatures 17 7.5 Determination of top, average and bottom liquid temperature rises . . 18 7.6 Determination of average winding temperature 18 7.7 Determination
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN6007622011POWERTRANSFORMERSTEMPERATURERISEFORLIQUIDIMMERSEDTRANSFORMERS 电力变压器 变压器 PDF

链接地址:http://www.mydoc123.com/p-575246.html