BS EN 50123-1-2003 Railway applications Fixed installations D C switchgear General《轨道交通 固定设备 直流开关装置 总则》.pdf
《BS EN 50123-1-2003 Railway applications Fixed installations D C switchgear General《轨道交通 固定设备 直流开关装置 总则》.pdf》由会员分享,可在线阅读,更多相关《BS EN 50123-1-2003 Railway applications Fixed installations D C switchgear General《轨道交通 固定设备 直流开关装置 总则》.pdf(50页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS EN 50123-1:2003 Railway applications Fixed installations D.C. switchgear Part 1: General The European Standard EN 50123-1:2003 has the status of a British Standard ICS 29.120.60; 45.020 BS EN 50123-1:2003 This British Standard, was published under the authority of the Standards P
2、olicy and Strategy Committee on 11 July 2003 BSI 11 July 2003 ISBN 0 580 42246 1 National foreword This British Standard is the official English language version of EN 50123-1:2003. It supersedes BS EN 50123-1:1996 which is withdrawn. The UK participation in its preparation was entrusted by Technica
3、l Committee GEL/9, Railway electrotechnical applications, to Subcommittee GEL/9/3, Fixed equipment, which has the responsibility to: A list of organizations represented on this subcommittee can be obtained on request to its secretary. Cross-references The British Standards which implement internatio
4、nal or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purport t
5、o include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committee any
6、 enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 46, an in
7、side back cover and a back cover. The BSI copyright date displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. Date CommentsEUROPEAN STANDARD EN 50123-1 NORME EUROPENNE EUROPISCHE NORM February 2003 CENELEC European Committee for Electro
8、technical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2003 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No
9、. EN 50123-1:2003 E ICS 29.120.60; 45.020 Supersedes EN 50123-1:1995English version Railway applications Fixed installations D.C. switchgear Part 1: General Applications ferroviaires Installations fixes Appareillage courant continu Partie 1: Gnralits Bahnanwendungen Ortsfeste Anlagen Gleichstrom-Sch
10、alteinrichtungen Teil 1: Allgemeines This European Standard was approved by CENELEC on 2002-09-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
11、Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translati
12、on under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Hun
13、gary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and United Kingdom. EN 50123-1:2003 2 Foreword This European Standard was prepared by SC 9XC, Electric supply and earthing systems for public transport equipment and ancillary appara
14、tus (fixed installations), of the Technical Committee CENELEC TC 9X, Electrical and electronic applications for railways. The text of the draft was submitted to the formal vote and was approved by CENELEC as EN 50123-1 on 2002-09-01. This European Standard supersedes EN 50123-1:1995. It has been pre
15、pared taking into account IEC document 9/578/FDIS (61992-1) in order to align technically as much as possible this EN 50123-1 and IEC 61992-1. These documents are to be considered as technically equivalent except for those references and peculiarities which are due to the European standardisation in
16、 the railway application field. The following dates were fixed: - latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2003-09-01 - latest date by which the national standards conflicting with the EN have to be w
17、ithdrawn (dow) 2005-09-01 Annexes designated “normative” are part of the body of the standard. Annexes designated “informative” are given for information only. In this standard, Annexes A, B and C are normative and Annexes D and E are informative. _ 3 EN 50123-1:2003 Contents 1 Scope.4 2 Normative r
18、eferences4 3 Definitions .6 3.1 General terms.6 3.2 Performance characteristics9 3.3 Components .13 3.4 Terms relating to d.c. circuit breakers, switch-disconnectors and associated relays .17 4 Service conditions and requirements.22 4.1 Environmental conditions 22 4.2 Insulation levels22 5 Standard
19、features and conventional assumptions.24 5.1 Standard features and conventional parameters for the main circuit 24 5.2 Standard features for auxiliary and control circuits.26 6 Temperature-rise limits.26 7 Tests27 7.1 General 27 7.2 Test tolerances.28 7.3 Tests on movable devices.28 7.4 Temperature-
20、rise test .30 7.5 Dielectric tests32 7.6 Short circuit and load switching conditions 32 7.7 Verification of the behaviour during short-time withstand current test.34 7.8 Verification of the manual control device for sturdiness and position indicator reliability.34 Annex A (normative) Diagrams for te
21、sts36 Annex B (normative) Environmental conditions for indoor installations 38 Annex C (normative) Search of critical currents for d.c. circuit breakers and switches.40 Annex D (informative) Recommended creepage distances42 Annex E (informative) Determination of maximum energy fault location .43 Bib
22、liography46 Figure A.1 - Diagram of the test circuit for checking the making and breaking capacities in short-circuit and load/overload switching conditions 37 Figure A.2 - Typical calibrations and interruption under short-circuit and load/overload switching conditions.38 Figure E.1 - Equivalent cir
23、cuit of a d.c. traction system 46 Figure E.2 - Ratio of I maxE /I ssto T s /T c .46 Table 1 - Insulation levels24 Table 2 - Test circuit parameters for maximum circuit energy 25 Table 3 - Preferred voltages for auxiliary and control circuits V 27 Table 4 - Temperature-rise limits for insulated coils
24、.27 Table 5 - Temperature-rise limits for various components28 Table 6 - Test tolerances.29 Table 7 - Recommended quantities and dimensions of copper bars .32 Table 8 - Values of forces or torques for the tests36 Table B.1 - Limits of sinusoidal vibrations40 Table D.1 - Material group identification
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN5012312003RAILWAYAPPLICATIONSFIXEDINSTALLATIONSDCSWITCHGEARGENERAL 轨道交通 固定 设备 直流 开关 装置 总则 PDF

链接地址:http://www.mydoc123.com/p-574562.html