1、 1 ANSI/BHMA A156.13-2012 Revision of ANSI/BHMA A156.13 2005 AMERICAN NATIONAL STANDARD FOR MORTISE LOCKS where wood screws are specified a hardwood equivalent is acceptable. It may be modified to allow strike attachment simulating the manufacturers mounting instructions provided the cutaway feature
2、 is maintained subjecting the strike and fasteners to the full test load. A recessed attachment is not permitted to remove the load from the strike. 19 7.5.7 Vertical Impactor Pendulum System ASTM F476 FIG. X1.6 7.5.8 Component Ram ASTM F476 paragraph 5.1.2 7.5.9 Door Ram ASTM F476 FIG. X1.2 8. OPER
3、ATIONAL TESTS Three locks shall be tested for each test in Sections 9.8 through 9.12 and failure of one in any category shall constitute failure of the complete test. 8.1 Dead Bolt Torque 8.1.1 Torque to retract dead bolt or torque to retract dead bolt and latch bolt by turn. A torque meter shall be
4、 applied to the turn and slowly rotated until the bolt or bolts clear the strike without contact. The maximum measured torque to retract the bolts shall not exceed the maximum specified. Requirements Maximum All Grades 9 lbf-in. (1 Nm) 8.1.2 Torque to retract dead bolt or torque to retract dead bolt
5、 and latch bolt by key. A torque meter shall be applied to the key and slowly rotated until the bolt or bolts clear the strike without contact. The maximum measured torque to retract the bolts shall not exceed the maximum specified. Requirements Maximum All Grades 9 lbf-in. (1 Nm) 8.2 Force or Torqu
6、e to Retract Latch Bolt or Latch Bolt and Dead Bolt 8.2.1 Knob or lever A torque meter shall be applied to the outside lever or knob to slowly rotate lever in a downward direction or rotate knob in a clockwise direction until the latch bolt clears the strike. When the knob is unidirectional, test on
7、ly in the direction of operation. The maximum measured torque to retract the latch bolt shall not exceed the maximum specified. Requirements Maximum Knobs - All Grades 9 lbf-in. (1Nm), Levers - All Grades 28 lbf-in. (3.1 Nm) Repeat 8.2.1 to the outside knob in a counterclockwise direction retracting
8、 the latch bolt. 20 Requirements. Maximum All Grades 9 lbf-in. (1 Nm) Repeat 8.2.1 to the inside lever or knob retracting dead bolt or latch bolt or both. Requirements. Maximum Knobs - All Grades 14 lbf-in. (1.6 Nm) Levers - All Grades 28 lbf-in. (3.1 Nm) Repeat 8.2.1 to the inside knob in a counter
9、clockwise direction retracting dead bolt or latch bolt or both. Requirements. Maximum All Grades 14 lbf-in. (1.6 Nm) 8.2.2 Entry handleset thumb piece. Apply a load at a point 1/4 in. (6.4 mm)1/32 in.(.8mm) from the end of the thumb piece until the latch bolt clears the strike. Center punch the thum
10、b piece to receive a pointed rod connected to a load gauge (see figure 5). The maximum load to retract the latch bolt shall not exceed the value specified. Requirements. Maximum All Grades 9 lbf (40N) 8.2.3 Paddle. A force meter shall be applied to the outside paddle in the direction of the opening
11、swing of the door 1 in. (25.4mm)1/32 in. (.8mm) from the free end of the paddle on the centerline retracting the dead bolt or latch bolt or both. Requirements Maximum All Grades 40 lbf (180N) 8.2.3.2 Repeat 8.2.3 to the inside paddle in the direction of the opening swing of the door 1 in. (25.4mm) f
12、rom the free end of the paddle retracting the dead bolt or latch bolt or both. Requirements Maximum All Grades 40 lbf (180N) 8.3 Force to Latch Door. A force meter shall be applied perpendicular to the face of the door to a point 1 in. (25.4 mm)1/16 in. (1.6mm) from the lock edge of the door and on
13、the center line of the latch bolt when the door is open just within 1/4 in. (6.4 mm) of the latch bolt contacting the lip of the strike. Close the door slowly by pushing the force meter against the door until the latch bolt fully enters the strike opening. The maximum measured force to fully latch t
14、he door shall not exceed the value specified. Requirements Maximum All Grades 4.5 lbf (20 N) 8.4 Torque to Retract Latch Bolt by Key 21 8.4.1 A torque meter shall be applied to the key and slowly rotated until the latch bolt clears the strike. The maximum measured torque to retract the latch bolt sh
15、all not exceed the maximum specified. 8.4.2 Repeat 8.4.1 in the opposite direction (when the lock construction permits operation in both clockwise and counterclockwise directions). Requirements. Maximum All Grades 9 lbf-in. (1 Nm) 8.5 Minimum Projection of Latch Bolt when depressed to dead latched p
16、osition. Depress the auxiliary dead latch and then depress the latch bolt to the deadlocked position. Measure the projection of the depressed latch bolt from the centerline of the lock front to the end of the latch bolt. The measured projection shall not be less than the minimum specified: Requireme
17、nts. Minimum Grade 1 9/16 in. (14.3 mm) Grade 2 and 3 3/8 in. (9.5 mm) 8.6 Minimum Projection of Auxiliary Dead Latch to Deadlock Latch Bolt. Depress the auxiliary dead latch slowly and test the latch bolt for the start of the deadlocking action. Measure the projection of the depressed auxiliary dea
18、d latch from the centerline of the lock front to the end of auxiliary dead latch at the point of the first effective deadlocking. The measured projection shall not be less than the minimum specified: Requirements Minimum Grade 1 3/8 in. (9.5 mm) Grade 2 and 3 5/16 in. (7.9 mm) 8.7 Warped Door Test T
19、orque to Retract Preloaded Bolt (Warped Door) A 50 lbf (222 N) force is applied perpendicular to the door at a point 1 in. (25.4 mm) from the lock edge of the door and on the center line of the bolt. The 50 lbf (222 N) shall load the bolt against the strike in the direction of opening the door and b
20、e sustained throughout the test. Breakage or other failure constitutes failure of the test. Failure of the trim also results in failure of the test. The maximum measured torque to retract the dead bolt or dead bolt and latch bolt to clear the strike without contact shall not exceed the value specifi
21、ed. 8.7.1 For Keys, Turns, Knobs or Levers, a torque measuring device shall be applied and slowly rotated until the bolt is withdrawn to within 1/8 in. (3.2 mm) of the lock front. The maximum measured torque shall not exceed the maximum specified below. For keys, does not apply to functions where th
22、e lever, knob, or paddle, after it is unlocked by key, can be operated to retract the latch bolt. 8.7.2 Lever, or Knob. A torque meter shall be applied to the outside lever or knob to slowly rotate the lever in a downward direction or rotate knob in a clockwise direction. The maximum measured force
23、shall not exceed the value specified in 8.7.5. When the knob is unidirectional, only test in the direction of operation. 8.7.2.1 Repeat 8.7.2 to the outside knob in a counterclockwise direction with the test applicable to the latch bolt or dead bolt or both. 8.7.2.2 Repeat 8.7.2 to the inside lever
24、downward or the knob in a clockwise direction with the test applicable to the latch bolt or dead bolt or both. 22 8.7.2.3 Repeat 8.7.2 to the inside knob in a counterclockwise direction with the test applicable to the latch bolt or dead bolt or both. 8.7.3 Entry Handleset Thumb Piece Apply a force g
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BHMAA156132012MORTISELOCKSLATCHESSERIES10001000 系列 榫槽锁 PDF

链接地址:http://www.mydoc123.com/p-542472.html