AWWA M9-2008 Concrete Pressure Pipe (Third Edition Errata 7 2013)《混凝土压力管 第三版》.pdf
《AWWA M9-2008 Concrete Pressure Pipe (Third Edition Errata 7 2013)《混凝土压力管 第三版》.pdf》由会员分享,可在线阅读,更多相关《AWWA M9-2008 Concrete Pressure Pipe (Third Edition Errata 7 2013)《混凝土压力管 第三版》.pdf(285页珍藏版)》请在麦多课文档分享上搜索。
1、Manual of Water Supply practiceS M9 9 M 1P-3E-1.25M-30009-10/08-SB AWWA is the authoritative resource for knowledge, information, and advocacy to improve the quality and supply of water in North America and beyond. AWWA is the largest organization of water professionals in the world. AWWA advances p
2、ublic health, safety, and welfare by uniting the efforts of the full spectrum of the entire water community. Through our collective strength, we become better stewards of water for the greatest good of the people and the environment. AdvocacyCommunicationsConferencesEducation and TrainingScience and
3、 TechnologySections The Authoritative Resource on Safe Water Concrete Pressure Pipe Concrete Pressure Pipe Third Edition D esigned for engineers, designers, contractors, and utility operators, this comprehensive operations manual explains the design, selection, specification, installation, and testi
4、ng of concrete pressure pipe in potable water service. M9, Concrete Pressure Pipe, covers everything about concrete water pipe: types, engineering, hydraulics, surge pressure, external loads, bedding, and backfilling. It also includes proper installation guidelines and safety practices for transport
5、ing concrete pipe. Cover photo courtesy of the American Concrete Pressure Pipe Association. 30009 Cover2.indd 1 9/23/2008 4:10:23 PMConcrete Pressure Pipe AWWA MANUAL M9 Third Edition Copyright 2008 American Water Works Association. All Rights Reserved.MANUAL OF WATER SUPPL Y PRACTICES M9, Third Edi
6、tion Concrete Pressure Pipe Copyright 1979, 1995, 2008 American Water Works Association All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information or retrieval system, exc
7、ept in the form of brief excerpts or quotations for review purposes, without the written permission of the publisher. Disclaimer The authors, contributors, editors, and publisher do not assume responsibility for the validity of the content or any consequences of their use. In no event will AWWA be l
8、iable for direct, indirect, special, incidental, or consequential damages arising out of the use of information presented in this book. In particular, AWWA will not be responsible for any costs, including, but not limited to, those incurred as a result of lost revenue. In no event shall AWWAs liabil
9、ity exceed the amount paid for the purchase of this book. Project Manager and Technical Editor: Franklin S. Kurtz Production: Melanie Schiff Manual Coordinator: Beth Behner Unless otherwise noted, all photographs used in this manual are provided courtesy of the American Concrete Pressure Pipe Associ
10、ation.Library of Congress Cataloging-in-Publication Data Concrete pressure pipe. - 3rd ed.p. cm. - (AWWA manual ; M9)Includes bibliographical references and index.ISBN 1-58321-549-21. Water-pipes. 2. Pipe, Concrete. 3. Pressure vessels. I. American Water Works Association.TD491.C66 2008628.15-dc2220
11、08010413Printed in the United States of America American Water Works Association 6666 West Quincy Avenue Denver, CO 80235 ISBN 1-58321-549-2 978-1-58321-549-4 Copyright 2008 American Water Works Association. All Rights Reserved. e-ISBN: 978-1-61300-071-7Errata to AWWA Manual M9, Concrete Pressure Pi
12、pe, 3rd ed. (July 2013) 1. On pages 130, 142, and 152, the equation Eq 9-5B should read: W e= D o H 12 + 1 4 D 2 o 12 2 2 2. On page 132, (D o= pipe outside diameter, ft) should read: D o= pipe outside diameter, in. 3. On page 136, Table 9-1, soil friction ( = 0.5) in the Soil Properties column for
13、Soil Type IV should read: = 0.4 Ideal crop marks Copyright 2008 American Water Works Association. All Rights Reserved.iii Contents List of Figures, vii List of Tables, xi Acknowledgments, xiii Chapter 1 Purpose and Scope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
14、 . . . . . . 1 Chapter 2 Description of Concrete Pressure Pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Prestressed Concrete Cylinder Pipe (ANSI/AWWA C301-Type Pipe), 3 Reinforced Concrete Cylinder Pipe (ANSI/AWWA C300-Type Pipe), 7 Reinforced Concrete Noncylinder Pipe (ANSI/AWW
15、A C302-Type Pipe), 8 Concrete Bar-Wrapped Cylinder Pipe (ANSI/AWWA C303-Type Pipe) , 10 Fittings and Special Pipe, 11 Reference, 12 Chapter 3 Hydraulics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Flow Formulas, 13 Effects of Aging on Ca
16、rrying Capacity, 20 Head Losses, 20 Determining an Economical Pipe Diameter, 21 Air Entrapment and Release, 25 Blowoff Outlets, 25 References, 25 Chapter 4 Surge Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Equations and Variables, 27
17、Negative Pressures, 30 Causes of Surge Pressure, 30 Control of Water Hammer, 31 References, 32 Chapter 5 External Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Major Installation Classifications, 33 Trench Conduits, 33 Embankment Conduits
18、, 37 Positive Projection Installations, 37 Earth Loads on Large Diameter ANSI/AWWA C303 Pipe, 41 Copyright 2008 American Water Works Association. All Rights Reserved.iv Negative Projection Installations, 42 Induced Trench Installations, 44 Jacked or Tunneled Conduits, 47 Determination of Live Load,
19、48 References, 56 Chapter 6 Bedding and Backfilling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 Introduction, 57 Rigid Pipe, 57 Semirigid Pipe, 59 Unstable Foundations, 60 References, 61 Chapter 7 Design of Reinforced Concrete Pressure Pipe . . . . . . . . .
20、. . . . . . . . . . . . . . 63 Information Required for Pipe Design, 63 Design Procedure for Rigid Pipe (ANSI/AWWA C300- and C302-Type Pipe), 64 Design Procedure for Semirigid Pipe (ANSI/AWWA C303-Type Pipe), 86 References, 93 Chapter 8 Design of Fittings and Appurtenances . . . . . . . . . . . . .
21、. . . . . . . . . . . . . . . . . 95 Fit tings, 95 Fit tings Design, 98 Specials , 117 References, 119 Chapter 9 Design of Thrust Restraints for Buried Pipe . . . . . . . . . . . . . . . . . . . . . . . . 121 Thrust Forces, 121 Hydrostatic Thrust, 121 Thrust Resistance, 123 Thrust Blocks, 124 Joints
22、 With Small Deflections, 126 Tied Joints, 132 Design Examples, 141 Combination Thrust-Restraint System, 167 Other Uses for Restraints, 170 References, 171 Chapter 10 Design of Pipe on Piers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173 Loads, 173 Copyright 2008
23、American Water Works Association. All Rights Reserved.v Cylinder Pipe, 173 Location of Piers, 177 Design of Pipe and Supports at Piers, 179 Protection of Exposed Concrete Pipelines, 183 References, 185 Chapter 11 Design of Subaqueous Installations . . . . . . . . . . . . . . . . . . . . . . . . . .
24、. . . . 187 Application, 187 Pipe Design Features, 187 Subaqueous Pipe Details, 190 Installation, 191 Testing, 194 Chapter 12 Design Considerations for Corrosive Environments . . . . . . . . . . . . . . . . 195 History, 195 Inherent Protective Properties, 195 Special Environmental Conditions, 196 Bo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AWWAM92008CONCRETEPRESSUREPIPETHIRDEDITIONERRATA72013 混凝土 压力 第三 PDF

链接地址:http://www.mydoc123.com/p-542461.html