AWS PHB-1-1994 Everyday Pocket Handbook for Arc Welding Steel《弧焊钢的每日小册》.pdf
《AWS PHB-1-1994 Everyday Pocket Handbook for Arc Welding Steel《弧焊钢的每日小册》.pdf》由会员分享,可在线阅读,更多相关《AWS PHB-1-1994 Everyday Pocket Handbook for Arc Welding Steel《弧焊钢的每日小册》.pdf(36页珍藏版)》请在麦多课文档分享上搜索。
1、The Everyday Pocket Handbook for Arc Welding Steel a series Compiled as a useful tool for on-the-job welding personnel by an AWS Presidential Task Group Reproduced by Global Engineering Documents With the Permission of AWS Under Royalty Agreement GLOBAL EAIGKNEERiNG DOCUIVIENTC“ American Welding Soc
2、iety 4b O 1994 by American Welding Society. All rights reserved. Printed in the United States of America Noto: Although care was taken in choosing and presenting the data in this guide, AWS cannot gurantee that it is error free. Further, this guide is not intended to be an exhaustive treatment of th
3、e topic and therefore may not include all available information, including with respect to safety and health issues. By publishing this guide, AWS does not insure anyone using the information it contains against any liabliity or injury to property or persons arising from that use. 2 Table of Content
4、s Basic Safety Precautions . 4 Electrodes: CIassication, Size, Amps, Carbon Arc Gouging Electrodes . 15 Deposition Rate for Mild Steel for GMAW 16 Recommended Copper Cable Sizes 17 Guide to Electrode Conditioning and Storage 18 Welding Positions - fillet (piate) 19 Welding Positions - Groove (plate)
5、 20 Welding Positions - Pipe 21 ThiCkms and Weight of steel Plates - 1/32 to 2 inch i 23 How to Use Weld Fillet Gage . 25 Pipe Size and Wall Thicknesses 26 Tests to Identify the Material 27 using Natural Gas 29 using Acetylene Gas 30 using Propylene Gas 31 Deposition Rate Classification System for C
6、arbon Steel Eiectrodes for SMAW . 6 SMAW E6010 Electrodes 7 SMAW E6011 Electrodes 7 SMAW E60 12 Electrodes 8 SMAW E601 3 Electrodes 8 SMAW E701 8 Electrodes 9 SMAW E7024 Electrodes 9 Classification System for Solid and Composite Carbon Steel Electrodes for GMAW 10 GMAW ER7OS-X Short Arc Electrodes 1
7、1 GMAW ER70S-X Spray Arc Electrodes 11 GMAW E70C-XX Metal Cored Electrodes 12 Classification System for Carbon Steel Electrodes for FCAW . 13 FCAW Self-shielded Electrodes 14 . Schedu, e for Oxyfuel Cuaing . . FCAW E7XT-X Gas-Shieldd Electrodes . 14 Basic Welding Symbols and Their Location 32 Locati
8、on of Elements of a Welding Symbol . 34 3 Basic Safety Precautions Burn Protection. Molten metal, sparks, slag, and hot wonk surfaces are produced by welding, cutting, and allied processes. These can cause burns if precautionary measures are not used. Workers should wear protective clothing made of
9、fire-resistant material. Pant cuffs, open pock- ets, or other places on clothing that can catch and retain molten metal or sparks should not be worn. High-top shoes or leather leggings and fire-resistant gloves should be worn. Pant legs should be worn over the outside of high-top shoes. Heimets or h
10、and shields that provide pro- tection for the face, neck, and ears, and a head covering to protect the head should be used. In addition, appropriate eye protection should be used. Electrical Hazards. Electric shock can kill. However, it can be avoided. Live electrical parts should not be touched. Th
11、e manufacturers instructions and recommended safe practices should be read and understood. Faulty installa- tion, improper grounding, and incorrect opera- tion and maintenance of electrical equipment are all sources of danger. All electrical equipment and the workpiece should be grounded. The workpi
12、ece lead is not a ground lead. It is used only to complete the welding circuit. A separate connection is required to ground the workpiece. The work- piece should not be mistaken for a ground connection. 4 Fumes and Gases. Many welding, cutting, and allied processes produce fumes and gases which may
13、be harmful to health. Avoid breath- ing the air in the fume plume directly above the arc. Do not weld in a confined area without a ventilation system. Use point-of-welding fume removal when welding galvanized steel, zinc, lead, cadmium, chromium, manganese, brass, or bronze. Do not weld on piping or
14、 containers that have held hazardous materials unless the containers have been inerted properly. Compressed Gas Cylinders. Keep caps on cylinders when not in use. Make sure that gas cylinders are chained to a wall or other struc- turai support. Radiation. Arc welding may produce ultra- violet, infra
15、red, or light radiation. Always wear protective clothing and eye protection to pro- tect the skin and eyes from radiation. Shield others from light radiation from your welding operation. AWS also recommends a personal copy of “Arc Welding Safely” and “Fire Safety in Welding and Cutting”. 5 Classific
16、ation System for Carbon Steel Electrodes for SMAW Designates an electrode. This designator may be deleted from the product imprint required for identification of the electrode. Designates the tensile strength (minimum), in ksi, of the weld metal when produced in accord- ance with the test assembly p
17、reparation procedure of this specification. Designates the welding position in which electrodes are usable, the type of covering, and the kind of welding current for which the electrodes are suitable. Optional Supplemental Designators: Designates that the elecirode meets the requirements of the abso
18、rbed moisture test (an optional supplemental test for all low hydrogen electrodes except the E7018M classification, for which the test is required). Designates that the elecwde meets the requirements of the diffusible hydrogen test (an optional supplemental test of the weld metal from low hydrogen e
19、lectrodes, as-received or conditioned - with an average value not exceeding “2” mi. of H, per 100g of deposited metal, where “Z“ is 4.8, or 16). Designates that the electrode (E7016, E7018, or E7024) meets the requirements for improved toughness - and ductility in the case of E7024. IXXYY-1HZR 6 SMA
20、W Electrodes I Il i SMAW Electrodes I E6010 II Diameter (in.) 3/32 E6011 i Amps Dep. Rale 50 0.8 I IL i 5/32 130 2.3 140 2.8 Diameter (in.) Dep. Rate 5/32 140 3.5 175 4.0 I I 130 I 2.3 I 7/32 190 3.5 190 4.5 I 3/16 1 170 1 4.0 1 t-+-+pj 220 5.1 I I1 1 1. Deposition rate in Ibar based on 100% arc tim
21、e. May vary within =IO%. The efficiency. with a 2“ stub loss, is approximately 60%. I. Deposition rate in IbAr based on 100% arc time. May vary within 110%. The efficiency, with a 2“ stub loss, is approximately 60%. 7 SMAW Electrodes I - E601 2 Diameter (fm) Amps Dep. Rate 118 100 2.4 i 30 2.9 I SMA
22、W Electrodes I i 18 100 i .8 135 3.0 E601 3 Diameter (in.) I Amps I Dep.Rate 3/16 I 75 I 1.2 1 180 3.2 220 4.1 1 I4 I 7/32 I 275 I 4.8 I 320 5.6 320 5.6 I 7/32 1 250 I 5.3 I I I 290 I 6.1 I I. Deposition :IO%. The CeQmCy. with a 2“ stub loss, is approximately 60%. in Ibsnir based on 100% arc time. M
23、ay vary within I. Deposition rate in IbsBir bascd on 100% arc time. May vary within 110%. The efficiency, with a 2” stub loss, is approximately 60%. 8 I SMAW Electrodes I Diameter (in.) 3/32 -1 - I CMAW Electrodes Amps Dep. Rate 70 1.4 110 1.7 Diameter (in.) I18 I 118 1 1 2.6 i 3 .O 5/32 3.1 Amps ep
24、. Rate 140 4.2 I E7024 I 3/16 240 7.2 245 7.5 1 5/32 I 180 I 5.3 I 114 400 11.6 12.6 I I 200 I 4.3 I I I 290 1- -9.11 7/32 250 1 340 I 7.4 I I. Deposition rate in Ibsnir based on 100% arc time. May vary within +IO%. The efficiency, with a 2“ stub loss. is approximately 60%. I 7/32 1 320 9.4 I 9 Clas
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AWSPHB11994EVERYDAYPOCKETHANDBOOKFORARCWELDINGSTEEL 弧焊钢 每日 PDF

链接地址:http://www.mydoc123.com/p-542042.html