ATIS T1 TR 1-1986 Status of the Compatibility Standard for the Interface between a Cellular Mobile Carrier and a Wireline Exchange Carrier (C-E Interface).pdf
《ATIS T1 TR 1-1986 Status of the Compatibility Standard for the Interface between a Cellular Mobile Carrier and a Wireline Exchange Carrier (C-E Interface).pdf》由会员分享,可在线阅读,更多相关《ATIS T1 TR 1-1986 Status of the Compatibility Standard for the Interface between a Cellular Mobile Carrier and a Wireline Exchange Carrier (C-E Interface).pdf(21页珍藏版)》请在麦多课文档分享上搜索。
1、KSC-STD-E-0002E MARCH 12, 2009 Supersedes KSC-STD-E-0002D June 11, 2007 HAZARDPROOFING OF ELECTRICALLY ENERGIZED EQUIPMENT, STANDARD FOR EAR 99 NO LICENSE REQUIRED The information contained in the document is technical in content, but not technical data as defined by the International Traffic in Arm
2、s Regulations (ITAR) or the Export Administration Regulations (EAR), and therefore is EAR 99 NLR, no export license required, suitable for public release. General Prohibition Six (Embargo) applies to all items subject to the EAR, i.e. items on the CCL and within EAR 99 NLR. You may not make an expor
3、t or re-export contrary to the provisions of part 746 (Embargos and Other Special Controls) of the EAR and 22 CFR part 126.1 of the ITAR. KSC EDDR #09186 ENGINEERING DIRECTORATENational Aeronautics and Space Administration John F. Kennedy Space Center KSC FORM 16-12 (REV. 6/95) PREVIOUS EDITIONS ARE
4、 OBSOLETE (CG 11/95) KSC-STD-E-0002E MARCH 12, 2009 Supersedes KSC-STD-E-0002D June 11, 2007 KSC Form 7-657 NS (01/09) KSC-STD-E-0002E March 12, 2009 CONTENTS 1. PURPOSE AND SCOPE.1 2. APPLICABLE DOCUMENTS .1 2.1 Governmental.1 2.1.1 Specifications.1 2.1.2 Standards2 2.1.3 Handbooks .2 2.2 Nongovern
5、mental.2 2.3 Order of Precedence.3 3. DEFINITIONS.3 4. GENERAL REQUIREMENTS.4 5. GUIDELINES4 5.1 Hazardous Locations and Classifications 4 5.2 Purging and Pressurizing .5 5.3 Equipment for Hazardous Areas6 5.3.1 Class and Properties.6 5.3.2 Cable Wiring Methods.6 5.4 Electrical Connections for Meter
6、s, Instruments, and Relays.8 6. QUALITY ASSURANCE PROVISIONS 8 7. PREPARATION FOR DELIVERY 8 8. NOTES.9 8.1 Intended Use 9 8.2 Notice.9 APPENDIX A. SPACE SHUTTLE ELECTRICAL-POWER HAZARDOUS-ZONE DOCUMENTATION 11 KSC-STD-E-0002E_DD_03122009.doc iii KSC-STD-E-0002E March 12, 2009 This page intentionall
7、y left blank. iv KSC-STD-E-0002E March 12, 2009 HAZARDPROOFING OF ELECTRICALLY ENERGIZED EQUIPMENT, STANDARD FOR 1. PURPOSE AND SCOPE This standard sets forth requirements for hazardproofing electrical installations and equipment located in hazardous (classified) and other locations designated as ha
8、zardous by the authority having jurisdiction (AHJ) at Kennedy Space Center (KSC) to prevent ignition of flammable liquids or hazardous fluids, gases, or vapors. This document defines the minimum requirement that KSC ground systems and equipment must meet. This document does not define how to design
9、systems and equipment, or encompass hazardproofing requirements associated with lightning protection, grounding, operational safety, toxicity, or chemical reactions. This standard does not apply to locations made hazardous because of the presence of high explosives (such as blasting agents or muniti
10、ons) or pyrophoric materials (those that ignite spontaneously in air). 2. APPLICABLE DOCUMENTS The following documents form a part of this document to the extent specified herein. When this document is used for procurement, including solicitations, or is added to an existing contract, the specific r
11、evision levels, amendments, and approval dates of said documents shall be specified in an attachment to the solicitation/statement of work/contract. Unless a specific edition is cited, the latest released edition applies. 2.1 Governmental 2.1.1 Specifications John F. Kennedy Space Center (KSC), NASA
12、 KSC-SPEC-E-0031 Cables, Electrical, Specification for 1 KSC-STD-E-0002E March 12, 2009 Military MIL-DTL-5015 Connectors, Electrical Circular Threaded, AN Type, General Specification for MIL-DTL-22992 Connectors, Plugs and Receptacles, Electrical, Waterproof, Quick Disconnect, Heavy Duty Type, Gener
13、al Specification for 2.1.2 Standards John F. Kennedy Space Center (KSC), NASA KSC-STD-132 Potting and Molding Electrical Cable Assembly Terminations, Standard for KSC-STD-E-0006 Instrumentation and Communications Cable Applications, Standard for KSC-STD-E-0011 Electrical Power Receptacles and Plugs,
14、 Standard for KSC-STD-E-0014 Wire and Cable Applications, Standard for 2.1.3 Handbooks John F. Kennedy Space Center (KSC), NASA GP-864, Volume IIA Electrical Ground Support Equipment Cables Handbook 2.2 Nongovernmental National Fire Protection Association NFPA 70 National Electric Code NFPA 430 Code
15、 for the Storage of Liquid and Solid Oxidizers NFPA 496 Standard for Purged and Pressurized Enclosures for Electrical Equipment 2 KSC-STD-E-0002E March 12, 2009 NFPA 497 Recommended Practice for the Classification of Flammable Liquids, Gases or Vapors and of Hazardous (Classified) Locations for Elec
16、trical Installations in Chemical Process Areas 2.3 Order of Precedence In the event of conflict between the documents cited herein and the contents of this document, the contents of this document shall supersede, except where otherwise noted. The NASA contract, purchase order, or program-level docum
17、entation shall take precedence over the contents of this document in the event of conflicting requirements. Nothing in this document supersedes applicable laws and regulation unless a specific exemption has been obtained. 3. DEFINITIONS For the purpose of this document, the following definitions sha
18、ll apply. a. authority having jurisdiction (AHJ): Organization, office, or individual responsible for approving equipment, materials, an installation, or a procedure. At KSC, the NASA Fire and Rescue Office is the AHJ. b. control drawing: Drawing or other document provided by the manufacturer of the
19、 intrinsically safe or associated apparatus (or of the nonincendive field wiring apparatus or associated nonincendive field wiring apparatus) that details the allowed interconnections between the intrinsically safe and associated apparatus or between the nonincendive field wiring apparatus or associ
20、ated nonincendive field wiring apparatus. c. facility: Structure or building that serves a particular purpose. d. hazardous location: Location where fire or explosion hazards may exist because of the presence of flammable gases, vapors, or liquids; combustible dust; or ignitable fibers or flyings. T
21、he area is classified in accordance with properties of the material responsible for the potential hazard and with the likelihood of the hazard actually being present. e. purged and pressurized: Condition achieved by (1) purging, or supplying an enclosure with a protective gas at a sufficient flow an
22、d positive pressure to reduce the concentration of any flammable gas or vapor initially present to an acceptable level; and (2) pressurizing, or supplying an enclosure with a protective gas, with or without continuous flow, at sufficient pressure to prevent the entrance of flammable gas or vapor, co
23、mbustible dust, or ignitable fibers. (For further information, see NFPA 496.) 3 KSC-STD-E-0002E March 12, 2009 f. intrinsically safe: “An assembly of interconnected intrinsically safe apparatus, associated apparatus, and interconnecting cables in that those parts of the system that may be used in ha
24、zardous (classified) locations are intrinsically safe circuits” (NFPA 70). 4. GENERAL REQUIREMENTS Design for all new electrical equipment to be used in hazardous (classified) locations shall comply with the intent of the applicable guidelines of NFPA 70 (latest released edition), NFPA 430 (latest r
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ATIST1TR11986STATUSOFTHECOMPATIBILITYSTANDARDFORTHEINTERFACEBETWEENACELLULARMOBILECARRIERANDAWIRELINEEXCHANGECARRIERCEINTERFACEPDF

链接地址:http://www.mydoc123.com/p-541605.html