1、 ATIS-0700019 ATIS Standard on - RF MINIMUM PERFORMANCE OF WGPRS INDOOR BEARER As a leading technology and solutions development organization, the Alliance for Telecommunications Industry Solutions (ATIS) brings together the top global ICT companies to advance the industrys most pressing business pr
2、iorities. ATIS nearly 200 member companies are currently working to address the All-IP transition, network functions virtualization, big data analytics, cloud services, device solutions, emergency services, M2M, cyber security, network evolution, quality of service, billing support, operations, and
3、much more. These priorities follow a fast-track development lifecycle from design and innovation through standards, specifications, requirements, business use cases, software toolkits, open source solutions, and interoperability testing. ATIS is accredited by the American National Standards Institut
4、e (ANSI). The organization is the North American Organizational Partner for the 3rd Generation Partnership Project (3GPP), a founding Partner of the oneM2M global initiative, a member of and major U.S. contributor to the International Telecommunication Union (ITU), as well as a member of the Inter-A
5、merican Telecommunication Commission (CITEL). For more information, visit www.atis.org. Notice of Disclaimer GPRS Radio Interface Stage 2“.1 3a 3GPP TS 43.071: “Location Services (LCS); Functional description Stage 2”.1 4 3GPP TS 45.001: “Physical layer on the radio path; General description“.1 1Thi
6、s document is available from the Third Generation Partnership Project (3GPP) at . ATIS-0700019 2 5 3GPP TS 45.004: “Modulation“.1 6 3GPP TS 45.008: “Radio subsystem link control“.1 7 3GPP TS 45.010: “Radio subsystem synchronization“.1 8 3GPP TS 51.010-1: “Mobile Station (MS) conformance specificatio
7、n Part 1: Conformance Specification“.1 9 3GPP TS 51.011: “Specification of the Subscriber Identity Module - Mobile Equipment (SIM - ME) interface“.1 10 ITU-T (formerly CCITT) Recommendation O.153: “Basic parameters for the measurement of error performance at bit rates below the primary rate“.211 ETS
8、 300 019-1-3: “Equipment Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 1-3: Classification of environmental conditions Stationary use at weather protected locations“.312 ETS 300 019-1-4: “Equipment Engineering (EE); Environmental conditions
9、 and environmental tests for telecommunications equipment; Part 1-4: Classification of environmental conditions Stationary use at non-weather protected locations“.3 13 3GPP TS 44.014: Individual equipment type requirements and interworking; Special conformance testing functions”.1 14 ATIS-1000610, G
10、eneric Procedures for Supplementary Services, 1990.415 3GPP TS 43.052: “GSM Cordless Telephony System (CTS); Phase 1; Lower layers of the CTS radio interface; Stage 2“.116 3GPP TS 45.005, Radio Transmission and Reception 1.2 Abbreviations Abbreviations used in this document are listed in 3GPP TR 21.
11、905. 1.3 Acronyms 8-PSK 8-ary Phase Shift Keying ARFCN Absolute Radio-Frequency Channel Number ATIS Alliance for Telecommunications Industry Solutions BLER Block Error Rate BSS Base Station System BTS Base Transceiver Station C/I Carrier to Interference Ratio 2This document is available from the Int
12、ernational Telecommunications Union. 3This document is available from the European Committee for Electrotechnical Standardization (CENELEC). 4This document is available from the Alliance for Telecommunications Industry Solutions (ATIS) at . ATIS-0700019 3 CW Continuous Wave DMAC Digital Mobile Atten
13、uation Code DRx Discontinuous Reception DTx Discontinuous Transmission ERP Effective Radiated Power FH Frequency Hopping GMSK Gaussian Minimum Shift Keying HS High Speed MAC Mobile Attenuation Code micro-BTS microcell Base Transceiver Station MS Mobile Station NER Nominal Error Rates O-QAM Offset Qu
14、adrature Ampitude Modulation PCS 8 PSK Coding Scheme pico-BTS picocell Base Transceiver Station PL Power Level RF Radio Frequency SFH Slow Frequency Hopping VMAC Voice Mobile Attenuation Code WGPRS Wideband General Packet Radio Service WTSC Wireless Technologies and Systems Committee 2 Frequency Ban
15、ds while the change from level 7 to level 8 uses the bottom row criteria. 4.1.1.2 1900 MHz The mean ERP of the mobile station is shown in the table below. The manufacturer should recommend the net power gain or loss of the antenna system to be installed with the mobile station such that the power me
16、asured at the transmitter output terminals can be directly related to the required ERP (typical antenna systems have 2.5 dB gain with respect to a half-wave dipole and 1.5 dB cable loss). The station class indicated by the mobile station at the beginning of any call will be assumed by the system to
17、be maintained throughout that call. ATIS-0700019 7 Table 4.3 Mobile Station Nominal Power Levels Mobile Station Power Level (PL) Mobile Attenuation Code (MAC) Nominal ERP(dBW) for Mobile Station Power Class (see Note 4) II III IV 0 0000 0.0 -2 1 0001 0.0 -2 2 0010 -2 -2 3 0011 -6 -6 4 0100 -10 -10 5
18、 0101 -14 -14 6 0110 -18 -18 7 0111 -22 -22 8 1000 -284dB -284dB 9 1001 -335dB -335dB 10 1010 -386dB -386dB NOTE 1: The three least significant bits of MAC are used in the VMAC field. All four bits of MAC are used in the DMAC field. NOTE 2: The output powers shown above shall be maintained within th
19、e range of +2 dB, -4 dB of nominal value for Power Levels 0 7, and within +2 dB, -6 dB of the nominal value for Power Levels 8 10 (see Note 3). NOTE 3: The Nominal Output Power for levels 8, 9, and 10 are expressed as a range, rather than an absolute value. When the mobile station changes to one of
20、these power levels, it shall insure that it stabilizes within the range centered around the target value for that level. For example, the target value for power level 8 in the 1900 MHz operating band is -28dBW. The mobile station is considered to be within the requirement provided it stabilizes with
21、in 4dB of this target level. Once the mobile station has stabilized, the operating tolerance is applied to the specific value within the nominal range on which the mobile station stabilized. NOTE 4: The Nominal ERP values in watts for power level 0 are: Class Power Level II. +0 dBW = 1.0 W III. Rese
22、rved IV. -2 dBW = 0.6 W NOTE 5: Only Power Class IV is applicable to the Indoor. ATIS-0700019 8 Table 4.4 Relative Step Accuracy vs. Power Level on a Single Channel Mobile Station Power Class II Levels (PL) Mobile Station Power Class IV Levels (PL) Step Between Successive Power Levels (dB) 0 7 2 7 4
23、 1 - 7 10 4 2 When the mobile station changes from power level X to power level X+1, it shall satisfy the requirements for the Nominal Output Power for that level. Additionally, the mobile station shall satisfy the requirements identified for the Relative Step Accuracy going into the X+1 Power Level
24、. Thus, the mobile station shall reduce its power such that it conforms to the Nominal level, with a reduction in power at least as great as the minimum specified by the Relative Step requirement. 4.1.2 Base Station The micro-BTS maximum output power per carrier measured at the antenna connector aft
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ATIS07000192015RFMINIMUMPERFORMANCEOFWGPRSINDOORBEARERPDF

链接地址:http://www.mydoc123.com/p-541311.html