ATIS 0600012 03-2012 Electrical Protection Considerations for Outdoor Coaxial Cable Runs for DS-3 and GPS Timing Signals.pdf
《ATIS 0600012 03-2012 Electrical Protection Considerations for Outdoor Coaxial Cable Runs for DS-3 and GPS Timing Signals.pdf》由会员分享,可在线阅读,更多相关《ATIS 0600012 03-2012 Electrical Protection Considerations for Outdoor Coaxial Cable Runs for DS-3 and GPS Timing Signals.pdf(15页珍藏版)》请在麦多课文档分享上搜索。
1、 ATIS-0600012.03 ATIS Standard on - ELECTRICAL PROTECTION CONSIDERATIONS FOR OUTDOOR COAXIAL CABLE RUNS FOR DS-3 AND GPS TIMING SIGNALS ATIS is the leading technical planning and standards development organization committed to the rapid development of global, market-driven standards for the informat
2、ion, entertainment and communications industry. More than 200 companies actively formulate standards in ATIS Committees and Forums, covering issues including: IPTV, Cloud Services, Energy Efficiency, IP-Based and Wireless Technologies, Quality of Service, Billing and Operational Support, Emergency S
3、ervices, Architectural Platforms and Emerging Networks. In addition, numerous Incubators, Focus and Exploratory Groups address evolving industry priorities including Smart Grid, Machine-to-Machine, Connected Vehicle, IP Downloadable Security, Policy Management and Network Optimization. ATIS is the N
4、orth American Organizational Partner for the 3rd Generation Partnership Project (3GPP), a member and major U.S. contributor to the International Telecommunication Union (ITU) Radio and Telecommunications Sectors, and a member of the Inter-American Telecommunication Commission (CITEL). ATIS is accred
5、ited by the American National Standards Institute (ANSI). For more information, please visit .Notice of Disclaimer however, it was written when the primary focus was on protection of hybrid fiber-coax plant for deployment of TV services to residential customers over RG-6, RG-59, RG-8, etc. - relativ
6、ely long run (thus more subject to EMI influence) coaxial cable plant with network-powered repeaters. While most of the test procedures of GR-2908 are applicable, this document intends to provide additional application guidance for outdoor DS-3 and GPS signals over 734A, 735A, low loss communication
7、s coax (such as LMR-400 or other LMR cables), hard-line coax, RG-59, and RG-8 type coax cable with relatively short (typically less than 450 feet) unrepeatered runs. ATIS-0600012.03 2 2 References The following standards contain provisions which, through referenced in this text, constitute provision
8、s of this ATIS Standard. At the time of publication, the editions indicated were valid (where no edition is indicated, the latest edition applies). All standards are subject to revision, and parties to agreements based on this ATIS Standard are encouraged to investigate the possibility of applying t
9、he most recent editions of the standards indicated below. 1 ATIS-0100510.1999(R2008), Network Performance Parameters for Dedicated Digital Services for Rates up to and Including DS3 Specifications.12 ATIS-0600333.2007, Grounding and Bonding of Telecommunications Equipment.13 ATIS-0600334.2008, Elect
10、rical Protection of Communications Towers and Associated Structures.14 ATIS-0600404.a.2005(R2010), Supplement to T1.404-2004, Network and Customer Installation Interfaces DS3 and Metallic Interface Specification.15 ATIS-0900101.2006, Synchronization Interface Standard.16 NFPA 70-2011, National Elect
11、rical Code (NEC).27 NFPA 780, Installation of Lightning Protection Systems.28 TIA/EIA J-STD-607-A, Commercial Building Grounding (Earthing) and Bonding Requirements for Telecommunications.39 ATIS-0600012, Electrical Protection Considerations for Broadband Systems.110 IEC 60529, Degrees of Protection
12、 Provided by Enclosures (IP Code).411 IEC 61196, Coaxial Communications Cables.412 IEEE 367, Recommended Practice for Determining the Electric Power Station Ground Potential Rise and Induced Voltage from a Power Fault.513 IEEE 487, Recommended Practice for the Protection of Wire-Line Communication F
13、acilities Serving Electric Power Locations.514 IEEE 1590, Recommended Practice for the Electrical Protection of Communication Facilities Serving Electric Supply Locations Using Optical Fiber Systems.515 ITU-T K.27, Bonding Configurations and Earthing Inside a Telecommunications Building Protection A
14、gainst Interference.616 MIL-STD-196E, Joint Electronics Type Designation System.717 MIL-C-39012, General Specification for Connectors, Coaxial, Radio Frequency.718 NEMA 250, Enclosures for Electrical Equipment (1000 Volts Maximum).819 Telcordia, GR-49, Outdoor Telephone Network Interface Devices.91T
15、his document is available from the Alliance for Telecommunications Industry Solutions, 1200 G Street N.W., Suite 500, Washington, DC 20005. 2This document is available from the National Fire Protection Association (NFPA). 3This document is available from the Telecommunications Industry Association (
16、TIA). 4This document is available from the International Electrotechnical Commission. 5This document is available from the Institute of Electrical and Electronics Engineers (IEEE). 6This document is available from the International Telecommunications Union. 7Available from the Department of Defense
17、Single Stock Point for Military Specifications and Standards, located at the Document Automation and Production Service, Building 4/D, 700 Robins Ave, Philadelphia, Pa. 19111-5094. 8This document is available from the National Electrical Manufacturers Association. ATIS-0600012.03 3 20 Telcordia, GR-
18、295, Mesh and Isolated Bonding Networks: Definition and Application to Telephone Central Offices.921 Telcordia, GR-974, Telecommunications Line Protector Units.922 Telcordia GR-1089, Electromagnetic Compatibility and Electrical Safety - Generic Criteria for Network Telecommunications Equipment.923 T
19、elcordia, GR-2908, Surge Protectors on Coaxial Lines at Customer Premises.924 Telcordia, GR-3111, Transmission Characteristics for Outside Plant Passive Copper Components.925 UL 497C, Standard for Safety Protectors for Coaxial Communications Circuits.103 Definitions, Acronyms, however, the impedance
20、 loss for DS-3 signal frequencies is relatively high. 734A cable is slightly larger, and thus its DS-3 signal loss is less. Since it is desirable to limit the cable loss to about 5 dB, the practical distance limit for DS-3 runs on 735A coaxial cable is about 60 m. For 734A cable, the typical maximum
21、 run distance is about 130 m. If longer runs are needed, solid-shield 75- characteristic CATV-type cable - such as RG-11 or QR-320 - may be used. The following table summarizes typical coaxial cables used for DS-3 outdoor transmission 11. ATIS-0600012.03 6 Table 1: Typical Outdoor DS-3 Coax Cable Pr
22、operties Cable Type Characteristic Impedance Typical Terminations Typical Attenuation for DS-3 Typical Max DS-3 Distance 735A 75 BNC 0.092 dB/m 60 m 734A 0.043 dB/m 130 m RG-11 F-type 0.023 dB/m 240 m QR-320 0.019 dB/m 300 m L1 GPS Timing signals are typically carried from the antenna to the timing
23、bays on LMR-400 coaxial cable (similar to the RG-8 16 type cable commonly used in CATV applications), and terminated with 50- N-type 17 connectors. LMR-type cables are considered to be low-loss communications cables. Because it is usually desired to limit total cable loss to approximately 30 dB for
24、most of these timing applications (cable loss may be offset by the gain of an active antenna, so actual cable loss and distance is manufacturer-specific), the typical maximum distance for an LMR-400 cable carrying GPS timing signals is about 150 m. For shorter runs, RG-59 or 734A cable is also somet
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ATIS0600012032012ELECTRICALPROTECTIONCONSIDERATIONSFOROUTDOORCOAXIALCABLERUNSFORDS3ANDGPSTIMINGSIGNALSPDF

链接地址:http://www.mydoc123.com/p-541221.html