1、ATIS-0600012.01 ATIS Standard on Electrical Primary Protection Considerations for Broadband xDSL Systems Alliance for Telecommunications Industry Solutions Approved December 8, 2017 Abstract: xDSL Broadband equipment is susceptible to disturbances that require the use of electrical primary protectio
2、n devices. These primary protectors could have a negative impact on the signal of interest during steady-state conditions as well as during protector switching or clamping operation. The characteristics of these electrical primary protectors and their impact on xDSL broadband signals are considered
3、herein. This is the first communication service platform specific document in a suite of ATIS Standards intended to provide requirements and guidance for the use of electrical primary protectors in various technology architectures. This particular ATIS Standard will address xDSL. ATIS-0600012.01 ii
4、Foreword The Alliance for Telecommunication Industry Solutions (ATIS) serves the public through improved understanding between providers, customers, and manufacturers. The Sustainability in Telecom: Energy and Protection (STEP) Committee formerly the Network Interface, Power, and Protection Committe
5、e (NIPP) engages industry expertise to develop standards and technical reports for telecommunications equipment and environments in the areas of energy efficiency, environmental impacts, power and protection. The work products of STEP enable vendors, operators and their customers to deploy and opera
6、te reliable, environmentally sustainable, energy efficient communications technologies. STEP is committed to proactive engagement with national, regional and international standards development organizations and forums that share its scope of work. The mandatory requirements are designated by the wo
7、rd shall and recommendations by the word should. Where both a mandatory requirement and a recommendation are specified for the same criterion, the recommendation represents a goal currently identifiable as having distinct compatibility or performance advantages. The word may denotes a optional capab
8、ility that could augment the standard. The standard is fully functional without the incorporation of this optional capability. Suggestions for improvement of this document are welcome. They should be sent to the Alliance for Telecommunications Industry Solutions, STEP, 1200 G Street NW, Suite 500, W
9、ashington, DC 20005. At the time of consensus on this document, STEP, which was responsible for its development, had the following leadership: E. Gallo, STEP Chair and STEP NEP Vice Chair (Ericsson) J. Fuller, STEP Vice Chair and STEP NEP Chair (AT Access transmission system on metallic access cable
10、s; Symmetrical single pair high bit rate Digital Subscriber Line (SDSL); Part 2: Transceiver requirements.9 106 ITU-T Recommendation G.991.1, High bit rate digital subscriber line (HDSL).10 107 ITU-T Recommendation G.991.2, Single-pair high-speed digital subscriber line (SHDSL) transceivers.10108 IT
11、U-T Recommendation G.992.1, Asymmetric digital subscriber line (ADSL) transceivers.10109 ITU-T Recommendation G.992.2, Splitterless asymmetric digital subscriber line (ADSL) transceivers.10110 ITU-T Recommendation G.992.3, Asymmetric digital subscriber line transceivers 2 (ADSL2).10111 ITU-T Recomme
12、ndation G.992.4, Splitterless asymmetric digital subscriber line transceivers 2 (splitterless ADSL2).10112 ITU-T Recommendation G.992.5, Asymmetric digital subscriber line (ADSL) transceivers - Extended bandwidth ADSL2 (ADSL2+).10113 ITU-T Recommendation G.993.1, Very high speed digital subscriber l
13、ine transceivers (VDSL).10114 ITU-T Recommendation G.993.2, Very high speed digital subscriber line transceivers 2 (VDSL2).10115 ITU-T Recommendation G.993.5, Self-FEXT cancellation (vectoring) for use with VDSL2 transceivers.103 Definitions, Acronyms, it will conduct current once its breakdown volt
14、age has been exceeded (it is a variable resistor model). 3.1.18 Positive Temperature Coefficient (PTC) thermistor: A current limiting device, the resistance of which increases as a function of the temperature caused by the heating effect of the current and PTC resistance. 3.1.19 Primary Protector: U
15、sed to protect an equipment interface and wiring system located where it diverts most of the stressful voltages and currents from propagation into the equipment thus protecting inside wiring. It also minimizes voltage gradients within outside plant wiring but does not limit current in outside plant
16、wiring. It is generally accessible, removable, and connected to equipotential bonding. 3.1.20 Quiescent State (Off-State): The surge protector, while not being exposed to external voltages that would cause it to operate, should present low loss at transmission frequencies. ATIS-0600012.01 5 3.1.21 T
17、hyristor: A semi-conductor device that conducts current by switching into a short-circuit once its breakdown voltage has been exceeded. The thyristor is reset back into its high-impedance state once the current falls below its holding current value. 3.1.22 Transverse Voltage (also known as Different
18、ial or Metallic Voltage): A voltage between the tip conductors and the ring conductors. 3.2 Acronyms Access transmission system on metallic access cables; Symmetrical single-pair high bit rate Digital Subscriber Line (SHDSL); Part 2: Transceiver requirements 105. ATIS-0600012.01 7 SHDSL is typically
19、 used as a transport technology to commercial customer locations due to its high-speed symmetric characteristics. SHDSL can be used by applications that require symmetric access. The international standard for SHDSL is ITU-T Recommendation G.991.2, Single-pair high-speed digital subscriber line (SHD
20、SL) transceivers 107. The highest signal frequencies for SHDSL are: 385kb/s 120 kHz; 784 kb/s 250 kHz; 1.56 Mb/s 500 kHz. ADSLx can transmit a high speed down-stream data rate up to 27 Mbps to the subscriber, a lower speed up-stream data rate up to 2 Mbps, and can coexist with Plain Old Telephone Se
21、rvice (POTS). When POTS and ADSLx coexist on the same twisted-pair, then a splitter/filter is required at the Network End (Central Office, Remote Terminal, etc.) and at the Remote End (Customer Location) to separate the POTS and ADSLx signals. The ADSLx technology is intended for applications such a
22、s internet access, multimedia access, and video on demand that can be provided by an asymmetric system. The standard for ADSL is ATIS-0600413, Network and Customer Installation Interfaces Asymmetric Digital Subscriber Line (ADSL) Metallic Interface 101. The international standards for ADSL are the I
23、TU-T standards ITU-T Recommendation G.992.1, Asymmetric digital subscriber line (ADSL) transceivers 108 and ITU-T Recommendation G.992.2, Splitterless asymmetric digital subscriber line (ADSL) transceivers 109. The ADSL2 standards are ITU-T Recommendation G.992.3, Asymmetric digital subscriber line
24、transceivers 2 (ADSL2) 110 and ITU-T Recommendation G.992.4, Splitterless asymmetric digital subscriber line transceivers 2 (splitterless ADSL2) 111. The ADSL2plus standard is ATIS-0600417, Spectrum Management for Loop Transmissions Systems 102. The international standard is ITU-T Recommendation G.9
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ATIS0600012012017ELECTRICALPRIMARYPROTECTIONCONSIDERATIONSFORBROADBANDXDSLSYSTEMSPDF

链接地址:http://www.mydoc123.com/p-541220.html