ASTM G87-2002(2007) Standard Practice for Conducting Moist SO2 Tests《对金属进行潮湿二氧化硫(SO2)的腐蚀试验的标准实施规程》.pdf
《ASTM G87-2002(2007) Standard Practice for Conducting Moist SO2 Tests《对金属进行潮湿二氧化硫(SO2)的腐蚀试验的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM G87-2002(2007) Standard Practice for Conducting Moist SO2 Tests《对金属进行潮湿二氧化硫(SO2)的腐蚀试验的标准实施规程》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: G 87 02 (Reapproved 2007)Standard Practice forConducting Moist SO2Tests1This standard is issued under the fixed designation G 87; the number immediately following the designation indicates the year of originaladoption or, in the case of revision, the year of last revision. A number in p
2、arentheses indicates the year of last reapproval. A superscriptepsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the apparatus and procedure to beused in conducting qualitative assessment tests in accordancewith the requirements of mater
3、ial or product specifications bymeans of specimen exposure to condensed moisture containingsulfur dioxide.1.2 The exposure conditions may be varied to suit particularrequirements and this practice includes provisions for use ofdifferent concentrations of sulfur dioxide and for tests eitherrunning co
4、ntinuously or in cycles of alternate exposure to thesulfur dioxide containing atmosphere and to the ambientatmosphere.1.3 The variant of the test to be used, the exposure periodrequired, the type of test specimen, and the criteria of failureare not prescribed by this practice. Such details are provi
5、ded inappropriate material and product purchase specifications.1.4 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.5 This standard does not purport to address all of thesafety concerns, if any associated with its use. It is t
6、heresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For a specificwarning statement, see 4.3.2. Referenced Documents2.1 ASTM Standards:2D 714 Test Method for Evaluating Degree of
7、Blistering ofPaintsD 1193 Specification for Reagent WaterD 1654 Test Method for Evaluation of Painted or CoatedSpecimens Subjected to Corrosive EnvironmentsG1 Practice for Preparing, Cleaning, and Evaluating Cor-rosion Test SpecimensG46 Guide for Examination and Evaluation of PittingCorrosion3. Sign
8、ificance and Use3.1 Moist air containing sulfur dioxide quickly produceseasily visible corrosion on many metals in a form resemblingthat occurring in industrial environments. It is therefore a testmedium well suited to detect pores or other sources ofweakness in protective coatings and deficiencies
9、in corrosionresistance associated with unsuitable alloy composition ortreatments.3.2 The results obtained in the test should not be regarded asa general guide to the corrosion resistance of the testedmaterials in all environments where these materials may beused. Performance of different materials i
10、n the test should onlybe taken as a general guide to the relative corrosion resistanceof these materials in moist SO2service.4. Apparatus4.1 The apparatus required for moist SO2testing consists ofa test chamber having an internal capacity of 300 L (10.6 ft3),a supply of sulfur dioxide with metering
11、device, specimensupports, provisions for heating the chamber, and necessarymeans of control. The size and detailed construction of theapparatus are optional, provided the conditions obtained meetthe requirements of this practice. Suitable apparatus which maybe used to obtain these conditions is desc
12、ribed inAppendix X1.4.2 Drops of condensing moisture which accumulate on theceiling of the chamber shall not be permitted to fall on thespecimens being tested.1This practice is under the jurisdiction of ASTM Committee G01 on Corrosionof Metals and is the direct responsibility of Subcommittee G01.05
13、on LaboratoryCorrosion Tests.Current edition approved May 1, 2007. Published May 2007. Originallyapproved in 1997. Last previous edition approved in 2002 as G 87-02.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Bo
14、ok of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.3 (WarningSuck-back into cylinder may cause explo-sion. Always use a check valv
15、e, vacuum break, or otherprotective apparatus in any line or piping from cylinder to testchamber to prevent suck-back. Installation of the chamberunder a fume hood is recommended.)5. Reagents5.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is in
16、tended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,where such specifications are available.3Other grades may beused, provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use wi
17、thout lessening theaccuracy of the determination.5.2 Purity of WaterUnless otherwise indicated, referencesto water shall be understood to mean reagent water as definedby Type IV of Specification D 1193.5.3 A commercially available source of bottled SO2gashaving a minimum purity of 99.9 % (liquid pha
18、se) with properregulator, and means of measuring the volumes of gas requiredfor delivery into test chamber shall be provided.5.4 The volume of gas delivered into test chamber shall bemeasured by means of either a properly calibrated flowmeter(rotameter type) with metering valve, or in a gas buret us
19、ingviscous paraffin oil as the pressure controlling fluid.5.4.1 The volume to be measured may be as small as 0.2 L.Measures should be taken to avoid errors from air contained indelivery tubes between flowmeter or gas burette and testchamber.6. Sampling6.1 The specific location of samples in a mill p
20、roduct, thenumber of samples that should be tested, and other factorsconcerning sampling, are not within the scope of this practice.These factors should be mutually agreed upon between pur-chaser and supplier (see 7.1).7. Test Specimens7.1 Select the number and type of test specimens, and theirshape
21、 and dimensions according to the specification coveringthe product or material being tested or agreed upon betweenpurchaser and supplier.7.2 The total combined exposed surface area of the materialtested at any one time should be substantially the same andunless otherwise agreed upon, it shall be 0.5
22、 6 0.1 m2(5.4 ft26 1ft2).7.2.1 More specimens of the same material may be added, ifneeded.7.3 To obtain quantitative corrosion-rate data, only materi-als with similar reactivities should be included in a test run.7.4 Preparation of Test Specimens:7.4.1 Suitably clean the specimens before testing (se
23、e Prac-tice G1). Unless otherwise agreed upon the cleaning methodshall be optional depending on the nature of the surface and ofthe likelihood of contamination. The cleaning method shall notinclude the use of abrasives (other than a paste of puremagnesium oxide), corrosive solvents, corrosion-promot
24、ingmaterials or protective film formers. Care in handling isnecessary so as not to recontaminate the test specimens.7.4.2 If test specimens are cut from a larger coated article,carry out the cutting in such a way that coating damage isminimized in the area adjacent to the cut. Unless otherwisespecif
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMG8720022007STANDARDPRACTICEFORCONDUCTINGMOISTSO2TESTS 金属 进行 潮湿 二氧化硫 SO2 腐蚀 试验 标准 实施 规程 PDF

链接地址:http://www.mydoc123.com/p-540734.html