ASTM F862-2011(2017) Standard Practice for pH and Chloride-ion Concentration of Aerospace Hydraulic Fluids《航空航天液压流体酸碱值和氯离子浓度的标准实施规程》.pdf
《ASTM F862-2011(2017) Standard Practice for pH and Chloride-ion Concentration of Aerospace Hydraulic Fluids《航空航天液压流体酸碱值和氯离子浓度的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM F862-2011(2017) Standard Practice for pH and Chloride-ion Concentration of Aerospace Hydraulic Fluids《航空航天液压流体酸碱值和氯离子浓度的标准实施规程》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F862 11 (Reapproved 2017)Standard Practice forpH and Chloride-ion Concentration of Aerospace HydraulicFluids1This standard is issued under the fixed designation F862; the number immediately following the designation indicates the year of originaladoption or, in the case of revision, the
2、 year of last revision. A number in parentheses indicates the year of last reapproval. A superscriptepsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the measurement of the pH andchloride ion of water extraction of aerospace hydraulic flu
3、ids.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish
4、appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.1.4 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of
5、 International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D512 Test Methods for Chloride Ion In WaterD1193 Specification for Reagent WaterE70 Test Method for pH of Aqueous Solutio
6、ns With theGlass Electrode3. Summary of Method3.1 The aerospace hydraulic fluid sample is shaken withwater, and the pH and the quantity of chloride ion aredetermined from the water layer.3.1.1 The pH is measured using a glass electrode and pHmeter.3.1.2 The quantity of the chloride ion is determined
7、 using achloride selective ion electrode and a selective ion meter.4. Significance and Use4.1 On application of the hydraulic fluid within the me-chanical fluidic system, the fluid may become contaminatedwith acid and chloride ion. Mechanical shearing of the hydrau-lic fluid in the presence of the m
8、inute quantity of water andresidual amount of organic solvents, used in cleaning, mayinitiate formation of acid and chloride ion. Measurements aredesired to control and maintain the cleanliness and non-corrosiveness of the fluidic system.5. Apparatus5.1 Combination pH Selective Ion Meter,5.2 Glass E
9、lectrodeThe pH response shall be 60.05 pH.5.3 Reference ElectrodeA calomel, silver/silver chloride,or other reference electrode of constant potential.5.4 Chloride Selective Ion Electrode.5.5 Double Junction Reference Electrode, sleeve-type5.6 Separatory Funnel, 250 mL.6. Reagents6.1 Water, reagent g
10、rade, Type IV, in accordance withSpecification D1193.6.2 Reference Buffer Solutions, SRM/RM 185, 186,and 187Materials supplied by the National Institute of Stan-dards and Technology with pH values.7. Standardization of pH Meter7.1 Standardize the pH meter in accordance with TestMethod E70.PART ApH M
11、EASUREMENT8. Procedure8.1 Add a 50-mL sample of hydraulic fluid and 50 mL ofreagent water to a 250-mL separatory funnel.8.2 Mix thoroughly. Allow for the water and oil layers toseparate completely.1This practice is under the jurisdiction of ASTM Committee F07 on Aerospaceand Aircraft and is the dire
12、ct responsibility of Subcommittee F07.07 on Qualifica-tion Testing of Aircraft Cleaning Materials.Current edition approved June 1, 2017. Published July 2017. Originally approvedin 1984. Last previous edition approved in 2011 as F862 11. DOI: 10.1520/F0862-11R17.2For referenced ASTM standards, visit
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF86220112017STANDARDPRACTICEFORPHANDCHLORIDEIONCONCENTRATIONOFAEROSPACEHYDRAULICFLUIDS 航空航天 液压 流体

链接地址:http://www.mydoc123.com/p-537426.html