ASTM F862-1993(2002) Standard Test Method for pH and Chloride-ion Concentration of Aerospace Hydraulic Fluids 《航空航天液压流体的氯离子浓度及pH值的试验方法》.pdf
《ASTM F862-1993(2002) Standard Test Method for pH and Chloride-ion Concentration of Aerospace Hydraulic Fluids 《航空航天液压流体的氯离子浓度及pH值的试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F862-1993(2002) Standard Test Method for pH and Chloride-ion Concentration of Aerospace Hydraulic Fluids 《航空航天液压流体的氯离子浓度及pH值的试验方法》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 862 93 (Reapproved 2002)Standard Test Method forpH and Chloride-ion Concentration of Aerospace HydraulicFluids1This standard is issued under the fixed designation F 862; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision
2、, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the measurement of the pH andchloride ion of water extraction of aerospace hydr
3、aulic fluids.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.
4、 Referenced Documents2.1 ASTM Standards:D 1193 Specification for Reagent Water23. Summary of Method3.1 The aerospace hydraulic fluid sample is shaken withwater, and the pH and the quantity of chloride ion aredetermined from the water layer.3.1.1 The pH is measured using a glass electrode and pHmeter
5、.3.1.2 The quantity of the chloride ion is determined using asilver/sulfide electrode and a specific ion meter.4. Significance and Use4.1 On application of the hydraulic fluid within the me-chanical fluidic system, the fluid may become contaminatedwith acid and chloride ion. Mechanical shearing of t
6、he hydrau-lic fluid in the presence of the minute quantity of water andresidual amount of organic solvents, used in cleaning, mayinitiate formation of acid and chloride ion. Measurements aredesired to control and maintain the cleanliness and noncorro-siveness of the fluidic system.5. Apparatus5.1 pH
7、 Meter, with expanded millivolt scale and a sensitiv-ity of 1 mV. The method can be adopted for use with aselective-ion meter.35.2 Glass ElectrodeThe pH response shall be 60.05 pH.5.3 Reference ElectrodeA calomel, silver/silver chloride,or other reference electrode of constant potential.5.4 Silver/S
8、ilver Sulfide Electrode.45.5 Double Junction Reference Electrode, sleeve-type.55.6 Separatory Funnel, 250 mL.5.7 Buret, 10-mL capacity.5.8 Titration Stand, preferably built as an integral part of themeter housing and provided with support for the electrodes andelectrical stimer, all connected to gro
9、und.5.9 Grans Plot Paper.66. Reagents6.1 Water, reagent grade, Type IV, in accordance withSpecification D 1193.6.2 Reference Buffer Solutions, Standards 185, 186,and 187Materials supplied by the National Bureau of Stan-dards with pH values.6.3 Silver Nitrate Solution, Standard (2.82 3 103M)Dissolve
10、4.7909 g of silver nitrate dissolved in 1 L of water anddiluted 1:10.7. Standardization of pH Meter7.1 Turn on the instrument, allow it to warm up thoroughly,and bring it to electrical balance in accordance with themanufacturers instructions. Wash the glass and referenceelectrodes with three changes
11、 of water. Form a fresh liquidjunction if a sleeve-type reference junction is used.7.2 Fill the sample cup with the first reference buffersolution and immerse the electrodes. If the pH meter is of thezero-null type, set the dial of the meter to equal pH value of thereference buffer solution. Engage
12、the operating button androtate the standardization knob until the meter is brought tobalance. If the pH meter is of the direct-reading type, engagethe operating button, turn the range switch to the properposition, and rotate the asymmetry-potential knob until thereading corresponds to the pH of the
13、reference buffer. Emptythe sample cup and repeat until two successive readings areobtained without adjustment of the controls.1This test method is under the jurisdiction of ASTM Committee F07 onAerospace and Aircraft and is the direct responsibility of Subcommittee F07.07 onQualification Testing of
14、Aircraft Cleaning Materials.Current edition approved Jan. 15, 1993. Published April 1993. Originallypublished as F 862 84. Last previous edition F 862 84.2Annual Book of ASTM Standards, Vol 11.01.3The Orion Model 901 has been found satisfactory.4The Orion Research Model has been found satisfactory.5
15、The Orion Model 90-01 has been found satisfactory.6Grans plot paper is available from Orion Research, Inc., 380 Putnam Ave.,Cambridge, MA 02139.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.7.3 Wash the electrodes and the sample cu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF86219932002STANDARDTESTMETHODFORPHANDCHLORIDEIONCONCENTRATIONOFAEROSPACEHYDRAULICFLUIDS 航空航天 液压

链接地址:http://www.mydoc123.com/p-537424.html