1、Designation: F 2021 06An American National StandardStandard Guide forDesign and Installation of Plastic Siphonic Roof DrainageSystems1This standard is issued under the fixed designation F 2021; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、 revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide covers design and installation considerationsfor plastic siphonic roof drain system
3、s for industrial, commer-cial, public, and residential buildings. Requirements for mate-rials, pipe, and fittings are included.1.2 The interchangeability of pipe and fittings made bydifferent manufacturers is not addressed in this guide. Transi-tion fittings for joining pipe and fittings of differen
4、t manufac-turers is provided for in the referenced pipe and fittingspecification.1.3 In referee decisions, the SI units shall be used formetric-sized pipe and inch-pound units for pipe sized in the IPSsystem (ANSI B36.10). In all cases, the values given inparentheses are for information only.2. Refe
5、renced Documents2.1 ASTM Standards:2D 696 Test Method for Coefficient of Linear Thermal Ex-pansion of Plastics Between 30C and 30C with aVitreous Silica DilatometerD 1600 Terminology for Abbreviated Terms Relating toPlasticsD 1785 Specification for Poly(Vinyl Chloride) (PVC) Plas-tic Pipe, Schedules
6、 40, 80, and 120D 2104 Specification for Polyethylene (PE) Plastic Pipe,Schedule 40D 2282 Specification for Acrylonitrile-Butadiene-Styrene(ABS) Plastic Pipe (SDR-PR)D 2447 Specification for Polyethylene (PE) Plastic Pipe,Schedules 40 and 80, Based on Outside DiameterD 2661 Specification for Acrylon
7、itrile-Butadiene-Styrene(ABS) Schedule 40 Plastic Drain, Waste, and Vent Pipeand FittingsD 2665 Specification for Poly(Vinyl Chloride) (PVC) Plas-tic Drain, Waste, and Vent Pipe and FittingsD 2751 Specification for Acrylonitrile-Butadiene-Styrene(ABS) Sewer Pipe and FittingsD 2949 Specification for
8、3.25-in. Outside Diameter Poly-(Vinyl Chloride) (PVC) Plastic Drain, Waste, and VentPipe and FittingsD 3034 Specification for Type PSM Poly(Vinyl Chloride)(PVC) Sewer Pipe and FittingsD 3350 Specification for Polyethylene Plastics Pipe andFittings MaterialsE84 Test Method for Surface Burning Charact
9、eristics ofBuilding MaterialsE 814 Test Method for Fire Tests of Through-PenetrationFire StopsE 1966 Test Method for Fire-Resistive Joint SystemsE 2393 Practice for On-Site Inspection of Installed FireResistive Joint Systems and Perimeter Fire BarriersF 412 Terminology Relating to Plastic Piping Sys
10、temsF 628 Specification for Acrylonitrile-Butadiene-Styrene(ABS) Schedule 40 Plastic Drain, Waste, and Vent PipeWith a Cellular CoreF 714 Specification for Polyethylene (PE) Plastic Pipe(SDR-PR) Based on Outside DiameterF 891 Specification for Coextruded Poly(Vinyl Chloride)(PVC) Plastic Pipe With a
11、 Cellular CoreF 1901 Specification for Polyethylene (PE) Pipe and Fit-tings for Roof Drain Systems2.2 ANSI/ASME Standards:A112.20.2 Qualification of Installers of Firestop Systemsand Devices for Piping Systems3A112.6.4 Roof, Deck and Balcony Drains3A112.6.9 Siphonic Roof Drains3B36.10 Standard Dimen
12、sions of Steel Pipe (IPS)32.3 ANSI/UL Standard:UL-1479 (see Test Method E 814)32.4 Other References:International Building Code (IBC)International Plumbing Code (IPC)Uniform Building Code (UBC)Uniform Plumbing Code (UPC)NFPA 5000 Building Code1This guide is under the jurisdiction of ASTM Committee F
13、17 on Plastic PipingSystems and is the direct responsibility of Subcommittee F17.63 on DWV.Current edition approved April 1, 2006. Published April 2006. Originallyapproved in 2000. Last previous edition approved in 2000 as F 2021 00.2For referenced ASTM standards, visit the ASTM website, www.astm.or
14、g, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.1Copyright ASTM Inter
15、national, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3. Terminology3.1 DefinitionsTerms and abbreviations as described inTerminologies F 412 and D 1600, respectively, shall apply inthis guide. General terminology pertaining to roof drains asdescribed in ANSI/
16、ASME A112.6.4 and ASME A112.6.9 shallalso apply in this guide.3.2 Definitions of Terms Specific to This Standard:3.2.1 crown, nthe elevation of the top of a pipe inner wall.3.2.2 drain, nany pipe which carries rain water, wastewater or waterborne wastes in a building drainage system.3.2.3 drainage s
17、ystem, nincludes all the piping withinpublic or private premises, which conveys sewage, rain water,or other liquid wastes to a legal point of disposal. It does notinclude the mains of public sewer treatment or disposal plants.3.2.4 siphonic roof drain, na roof drain with a fixeddevice allowing water
18、 to enter without the ingress of air thatsustains a negative differential fluid head within the pipesystem thereby inducing flow without pipe gradient (pitch).4. Significance and Use4.1 The information provided in this standard guide isintended for use by designers and specifiers of siphonic roofdra
19、inage systems and their related components. Specifically,this guide addresses the use and limitations of plastic pipe andfittings in siphonic roof drainage systems where internaloperating pressures are typically sub-atmospheric.5. Procedure5.1 GeneralRefer to the governing plumbing code (forexample,
20、 IPC, UPC) to determine if plastic pipe and fittings arepermitted for building roof drainage systems in the projectjurisdiction. When permitted, select the appropriate material aslisted in the plumbing code that is approved for roof drainageapplications. Use of plastic pipe materials not approved by
21、 thegoverning code must be approved by the local authority havingjurisdiction. Regardless of material approval, use plastic pipematerials only when not prohibited by fire resistance require-ments of the governing building code (that is, NFPA 5000,IBC, UPC). Pipe materials must also meet the fire res
22、istiverequirements as specified in the building code and as deter-mined by Test Method E84.5.1.1 Specific types of PVC pipe appropriate for siphonicroof drainage systems include, but are not limited to: Specifi-cations D 2665, D 2949, and D 3034. When pipe diameters of212-in. (64-mm) must be specifi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF20212006STANDARDGUIDEFORDESIGNANDINSTALLATIONOFPLASTICSIPHONICROOFDRAINAGESYSTEMS 塑料 虹吸 屋面 排水系统

链接地址:http://www.mydoc123.com/p-536313.html