1、Designation: F1980 07 (Reapproved 2011)Standard Guide forAccelerated Aging of Sterile Barrier Systems for MedicalDevices1This standard is issued under the fixed designation F1980; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、 year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide provides information for developing accel-erated aging protocols to rapidly determine the effects,
3、 if any,due to the passage of time on the sterile integrity of the sterilebarrier system (SBS), as defined in ANSI/AAMI/ISO116071:2006 and the physical properties of their componentpackaging materials.1.2 Information obtained using this guide may be used tosupport expiration date claims for medical
4、device sterile barriersystems.1.3 The accelerated aging guideline addresses the sterilebarrier systems in whole with or without devices. The sterilebarrier system material and device interaction compatibilitythat may be required for new product development or theresulting evaluation is not addressed
5、 in this guide.1.4 Real-time aging protocols are not addressed in thisguide; however, it is essential that real-time aging studies beperformed to confirm the accelerated aging test results usingthe same methods of evaluation.1.5 Methods used for sterile barrier system validation,which include the ma
6、chine process, the effects of the steriliza-tion process, environmental challenge, distribution, handling,and shipping events, are beyond the scope of this guide.1.6 This guide does not address environmental challengingthat stimulates extreme climactic conditions that may exist inthe shipping and ha
7、ndling environment. Refer to PracticeD4332 for standard conditions that may be used to challengethe sterile barrier system to realistic extremes in temperatureand humidity conditions. See Terminology F1327 for a defini-tion of “environmental challenging.”1.7 This standard does not purport to address
8、 all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D4332 Practice fo
9、r Conditioning Containers, Packages, orPackaging Components for TestingE337 Test Method for Measuring Humidity with a Psy-chrometer (the Measurement of Wet- and Dry-Bulb Tem-peratures)F17 Terminology Relating to Flexible Barrier PackagingF1327 Terminology Relating to Barrier Materials for Medi-cal P
10、ackaging3F2097 Guide for Design and Evaluation of Primary FlexiblePackaging for Medical Products2.2 AAMI Standards:ANSI/AAMI/ISO 116071: 2006, Packaging for TerminallySterilized Medical Devices4AAMI TIR 222007, Guidance for ANSI/AAMI/ISO11607, Packaging for Terminally Sterilized Medical De-vices43.
11、Terminology3.1 DefinitionsFor general definitions of packaging formedical devices, seeANSI/AAMI/ISO 11607. For terminologyrelated to barrier materials for medical packaging see Termi-nology F17.3.2 Definitions of Terms Specific to This Standard:3.2.1 accelerated aging (AA), nstorage of samples at an
12、elevated temperature (TAA) in order to simulate real time agingin a reduced amount of time.3.2.2 accelerated aging factor (AAF), nan estimated orcalculated ratio of the time to achieve the same level ofphysical property change as a sterile barrier system stored atreal time (RT) conditions.1This guid
13、e is under the jurisdiction of ASTM Committee F02 on FlexibleBarrier Packaging and is the direct responsibility of Subcommittee F02.50 onPackage Design and Development.Current edition approved Aug. 1, 2011. Published November 2011. Originallyapproved in 1999. Last previous edition approved in 2007 a
14、s F1980 07. DOI:10.1520/F1980-07R11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn. The last appr
15、oved version of this historical standard is referencedon www.astm.org.4Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, Un
16、ited States.3.2.3 accelerated aging temperature (TAA), nthe elevatedtemperature at which the aging study is conducted, and it maybe based on the estimated storage temperature, estimated usagetemperature, or both.3.2.4 accelerated aging time (AAT), nthe length of timethe accelerated aging is conducte
17、d.3.2.5 ambient temperature (TRT), nstorage temperaturefor real-time aging (RT) samples that represents storage con-ditions.3.2.6 sterile barrier system shelf life, nthe amount of realtime that a sterile barrier system can be expected to remain instorage at ambient conditions, or under specified con
18、ditions ofstorage, and maintain its critical performance properties.3.2.7 real-time aging (RT), nstorage time of samples atambient conditions.3.2.8 real-time equivalent (RTE), namount of real-timeaging to which given accelerated aging conditions are esti-mated to be equivalent.3.2.9 zero time (t0),
19、nthe beginning of an aging study.3.3 Symbols:Q10= an aging factor for 10C increase or decrease intemperature.Tm= temperature at which a material melts.Tg= glass transition temperature.Ta= alpha temperature; heat distortion temperature.4. Significance and Use4.1 The loss of sterile barrier system int
20、egrity may occur asa result of physical properties of the materials and adhesive orcohesive bonds degrading over time and by subsequent dy-namic events during shipping and handling.4.2 ISO 116071:2006, clause 6, states that “the packagingsystem shall provide physical protection and maintain integrit
21、yof the sterile barrier system. The sterile barrier system shallmaintain sterility to the point of use or until the expiry date.Stability testing shall demonstrate that the sterile barrier systemmaintains integrity over time. Stability testing using acceler-ated aging protocols shall be regarded as
22、sufficient evidence forclaimed expiry date until data from real time aging studies areavailable.”4.3 Real time aging programs provide the best data toensure that sterile barrier system materials and sterile barriersystem integrity do not degrade over time. However, due tomarket conditions in which p
23、roducts become obsolete in ashort time, and the need to get new products to market in theshortest possible time, real time aging studies do not meet thisobjective. Accelerated aging studies can provide an alternativemeans. To ensure that accelerated aging studies do trulyrepresent real time effects,
24、 real time aging studies must beconducted in parallel to accelerated studies. Real time studiesmust be carried out to the claimed shelf life of the product andbe performed to their completion.4.4 Conservative accelerated aging factors (AAFs) must beused if little is known about the sterile barrier s
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF198020072011STANDARDGUIDEFORACCELERATEDAGINGOFSTERILEBARRIERSYSTEMSFORMEDICALDEVICES 医疗器械 无菌 阻隔

链接地址:http://www.mydoc123.com/p-536217.html