1、Designation: F 302 04Standard Practice forField Sampling of Aerospace Fluids in Containers1This standard is issued under the fixed designation F 302; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A numb
2、er in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers field sampling of fluids fromhermetically sealed containers and other fluid containers of208-L (55-gal) volume maximu
3、m. It may be utilized atmanufacturing, storage, or use levels for obtaining representa-tive fluid samples for chemical, physical, or particulate matterdeterminations.1.2 Use of this practice depends upon variables such as fluidtoxicity, restrictive fluid odors, fluid flammability, and so forth.It is
4、 suitable for most hydraulic fluids; however, care should beexercised in determining compatibility before use.21.3 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.4 This standard does not purport to address all of thesafety c
5、oncerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For hazard state-ment, see 6.5.1.2. Referenced Documents2.1 ASTM Standards:3D
6、1193 Specification for Reagent WaterD 1836 Specification for Commercial HexanesD 2021 Specification for Neutral Detergent, 40 PercentAlkylbenzene Sulfonate Type4D 4898 Test Method for Insoluble Contamination of Hy-draulic Fluids by Gravimetric AnalysisF 311 Practice for Processing Aerospace Liquid S
7、amples forParticulate Contamination Analysis Using Membrane Fil-tersF 314 Test Method for Identification of Metallic and Fi-brous Contaminants in Aerospace Fluids42.2 DoD Standard:5MIL-C-81302 Cleaning Compound Solvent Trichlorotrif-luoroethane3. Summary of Practice3.1 The minimum requirements for c
8、ontainer agitation,sample withdrawal, and sample transfer are given in thispractice. Precautions to ensure sampling reliability are in-cluded in the procedure to the extent required by normalprocessing conditions. The procedure involves agitating thecontainer, withdrawing with a suitable instrument
9、capable ofcreating a vacuum, a predetermined quantity of fluid, andimmediately transferring it to a vessel, properly identified, tohold for analysis by a stipulated method.4. Significance and Use4.1 Samples obtained by use of this practice are intended forprocessing in accordance with Practice F 311
10、, Test MethodD 4898, and Test Method F 314, and other chemical orphysical methods of analysis.5. Apparatus5.1 Pipet, volumetric transfer or equivalent rubber-bulbtype. A taper-jointed type, as shown in Fig. 1, 560 mm (22 in.)long, calibrated to deliver 100 mL at 20C, is also acceptable.This type pro
11、vides for ease of maintenance by being separableat the midpoint of the bulb.NOTE 1The volume capacities selected for the pipet and samplebottles shall be as required for the sample volume desired. Normally a 1006 5-mL sample is standard, which would require a capacity of approxi-mately 125 mL. Unles
12、s otherwise indicated, it is intended that a samplevolume of 100 6 5 mL be used for accomplishing the methods definedherein.5.2 Bottles, sample, wide-mouth type (Note 1).5.3 Solvent Filtering DispenserAn apparatus to dispensea stream of 2.0 m or finer membrane-filtered fluid.5.4 Vinylidene Chloride,
13、 Polyethylene Terephthalate, orPolyamide Sheet, 0.1 mm (4-mil) min.1This practice is under the jurisdiction of ASTM Committee E21 on SpaceSimulation and Applications of Space Technology and is the direct responsibility ofSubcommittee E21.05 on Contamination.Current edition approved Sept. 1, 2004. Pu
14、blished September 2004. Originallyapproved in 1965. Last previous edition approved in 2000 as F 302 78 (2000).2Where a special environment is required, a Proposed Laboratory Method forSampling Aerospace Fluids in Containers is under development in the committee.For further information write to B. R.
15、 Hall, American Petroleum Institute, 1220 LSt., N.W., Washington, D. C. 20005.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page on
16、the ASTM website.4Withdrawn.5Available from Standardization Documents Order Desk, Bldg. 4 Section D, 700Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS. Also available fromDoD ASSIST website, http:/assist.daps.dla.mil/online/start.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C
17、700, West Conshohocken, PA 19428-2959, United States.5.5 Beverage Can Opener (Unplated), sharpened, de-burred.6. Reagents6.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Com
18、mit-tee on Analytical Reagents of the American Chemical Society,where such specifications are available.6Other grades may beused, provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the determination.6.2 Purity of WaterUn
19、less otherwise indicated, referencesto water shall be understood to mean reagent water conformingto Specification D 1193.6.3 Detergent, free-rinsing. Material conforming to Specifi-cation D 2021 is suitable.6.4 Isopropyl Alcohol, acetone-free.76.5 Ligroine (Petroleum Ether), 30 to 60C.6.5.1 WarningL
20、igroine and hexane are highly flammableand should be handled with adequate precautions.NOTE 2Ligroine is suggested because of its high-evaporation rate andrelatively negligible residue (0.001 %). Other solvents are acceptable asrequired by the sampling activity, when a comparable evaporation andresi
21、due is considered, such as commercial hexanes (see SpecificationD 1836), trichlorotrifluoroethane conforming to MIL-C-81302, and soforth. In any case, reagent selected should not have a harmful effect on thesampling apparatus, sampled fluid, or the equipment to be used inprocessing the sample, or bo
22、th.7. Preparations of Apparatus and Reagents7.1 Apparatus used in this practice shall be prepared by areliable process for assurance of essentially contamination-freesurfaces.NOTE 3It is recommended that a process shall be used as described inTest Method D 4898 or Practice F 311.7.2 Reagents used in
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF3022004STANDARDPRACTICEFORFIELDSAMPLINGOFAEROSPACEFLUIDSINCONTAINERS 容器 航空航天 流体 现场 取样 标准 实施 规程 PDF

链接地址:http://www.mydoc123.com/p-532545.html