《ASTM E2766-2013 Standard Practice for Installation of Roof Mounted Photovoltaic Arrays on Steep-Slope Roofs《陡坡屋顶上屋顶安装光伏阵列安装的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2766-2013 Standard Practice for Installation of Roof Mounted Photovoltaic Arrays on Steep-Slope Roofs《陡坡屋顶上屋顶安装光伏阵列安装的标准实施规程》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2766 13Standard Practice forInstallation of Roof Mounted Photovoltaic Arrays on Steep-Slope Roofs1This standard is issued under the fixed designation E2766; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of
2、last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice details minimum requirements for theinstallation of roof mounted photovoltaic arrays on steep-sloped roo
3、fs with water-shedding roof coverings. These re-quirements include proper water-shedding integration with theroof system, material properties, flashing of roof penetrations,and sufficient anchoring per regional design load requirements.1.1.1 This practice does not apply to building-integrated oradhe
4、sively attached photovoltaic systems that are applied asroof-covering components.1.2 This practice does not cover the electrical aspects ofinstallation.1.3 Installation considerations are divided into two distinctaspects: the interface between the photovoltaic module and thearray mounting structure,
5、 and the interface between the arraymounting structure and the roof or roof structure.1.4 Safety and hazard considerations unique to thisapplication, such as worker fall protection, electrical exposure,accessibility of modules, and roof clearance around the perim-eter of the array are addressed by o
6、ther codes, standards, orauthorities having jurisdiction.1.5 This practice is intended to provide recommendedinstallation practices for use by installers, specifiers,inspectors, or for specification by photovoltaic module manu-facturers.1.6 This practice provides minimum guidelines and shouldbe used
7、 in conjunction with module and mounting systemmanufacturers instructions. This practice offers a set of in-structions for performing one or more specific operations. Thisdocument cannot replace education or experience and shouldbe used in conjunction with professional judgment. Not allaspects of th
8、is practice may be applicable in all circumstances.ThisASTM Standard is not intended to represent or replace thestandard of care by which the adequacy of a given professionalservice must be judged, nor should this document be appliedwithout consideration of a projects many unique aspects. Theword “S
9、tandard” in the title means only that the document hasbeen approved through the ASTM consensus process.1.7 This practice is not intended to replace or supersede anyother applicable local codes, standards or Licensed DesignProfessional instructions for a given installation.1.8 This standard does not
10、purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific hazards aregiven in Section 8.2.
11、 Referenced Documents2.1 ASTM Standards:2D1079 Terminology Relating to Roofing and WaterproofingD1761 Test Methods for Mechanical Fasteners in WoodE136 Test Method for Behavior of Materials in a VerticalTube Furnace at 750CE772 Terminology of Solar Energy Conversion2.2 AAMA Standards:3AAMA 800 Volun
12、tary Specifications and Test Methods forSealants2.3 ASCE Standards:4ASCE 7 Minimum Design Loads for Buildings and OtherStructures2.4 IEC Standards:5IEC 617301 (200410) Photovoltaic (PV) Module SafetyQualificationPart One: Requirements for Construction1This practice is under the jurisdiction of ASTM
13、Committee E44 on Solar,Geothermal and Other Alternative Energy Sources and is the direct responsibility ofSubcommittee E44.09 on Photovoltaic Electric Power Conversion.Current edition approved June 1, 2013. Published July 2013. DOI: 10.1520/E2766-132For referenced ASTM standards, visit the ASTM webs
14、ite, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American Architectural Manufacturers Association (AAMA),1827 Walden Office Sq., Suite 550, Schau
15、mburg, IL 60173, http:/www.aamanet.org.4Available from American Society of Civil Engineers (ASCE), 1801 AlexanderBell Dr., Reston, VA 20191, http:/www.asce.org.5Available from International Electrotechnical Commission (IEC), 3, rue deVaremb, P.O. Box 131, CH-1211 Geneva 20, Switzerland, http:/www.ie
16、c.ch.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States12.5 UL Standards:6UL 1703 Standard for Flat-Plate Photovoltaic Modules andPanelsUL746C Polymeric MaterialsUse in Electrical EquipmentEvaluationsUL 609501 Table J.1 Electrotechnical
17、Potentials (V)2.6 Other Standards:IBC International Building Code7IEC International Electrical Code7IFC International Fire Code7NFPA 1 Fire Protection Code8NDS National Design Specification for Wood Construction93. Terminology3.1 Definitions: Definitions of terms used in this standardmay be found in
18、 Terminology D1079 and E772.3.1.1 steep-slope, adjin roofing, that which commonlydescribes an incline of a roof which is greater than 25 % (14or 3:12 vertical rise to horizontal run). D1079.3.2 Definitions of Terms Specific to This Standard:3.2.1 array mounting structure, n all structural and me-cha
19、nical materials used to support and anchor the photovoltaicmodules on the roof system between the attachment system andthe roof deck.3.2.2 attachment system, nall structural and mechanicalmaterials used to support and anchor the photovoltaic modulesto the array mounting structure.3.2.3 design life,
20、nthe period of time during which asystem component is expected to perform its intended function,without significant degradation of performance and withoutrequiring major maintenance or replacement. E7723.2.4 licensed design professional, LDP, nan individuallicensed to approve structural designs in t
21、he state or jurisdic-tion where the roof mounted photovoltaic array will beinstalled.3.2.5 representative section, none or more modules con-nected to an array mounting structure utilizing the sameconnecting devices as would be used in an installation.4. Significance and Use4.1 With the rapid growth
22、of the use of photovoltaic systemsin buildings, roof mounted arrays continue to be one of themost prevalent forms of installations. These roof mountedarrays typically feature penetrations into the roof system,which can result in water leakage issues if not properly flashedor applied to the roof syst
23、em.4.2 Structural integrity and durability of the application ofthe roof mounted array to the roof system must be adequate perapplicable codes and regulations. This applies to both thephotovoltaic module-to-array mounting structure interface andthe array mounting structure-to-roof interface.4.3 The
24、installation of roof mounted arrays presents certainhazards that must be addressed, which include fall protection,carrying loads up ladders, wind and rain exposure duringinstallation, and electrical exposure during connections.4.4 The topics covered in 4.1 through 4.3 are potentially asignificant ba
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME27662013STANDARDPRACTICEFORINSTALLATIONOFROOFMOUNTEDPHOTOVOLTAICARRAYSONSTEEPSLOPEROOFS 陡坡 屋顶 安装

链接地址:http://www.mydoc123.com/p-531850.html