《ASTM E2484-2008 Standard Specification for Multi-Story Building External Evacuation Controlled Descent Devices《多层建筑外部疏散缓降器的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2484-2008 Standard Specification for Multi-Story Building External Evacuation Controlled Descent Devices《多层建筑外部疏散缓降器的标准规范》.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 2484 08Standard Specification forMulti-Story Building External Evacuation Controlled DescentDevices1This standard is issued under the fixed designation E 2484; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year
2、 of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers the requirements, perfor-mance, design, marking instructions, test methods and ancil-la
3、ry components of Multi-Story Building External EvacuationControlled Descent Device (CDD) systems for emergencyescape of persons who cannot use the standard exit facilities inmulti-story buildings, defines requirements for their installa-tion, periodic maintenance when installed and instructions fort
4、heir use.1.2 This specification does not apply to personal escapeparachutes, rope, chain ladders or rappelling devices.1.3 This specification does not apply to ancillary compo-nents used with and included in CDD systems, harnesses,connecting hardware, signage, special evacuation openings,personal pr
5、otection equipment or devices and other compo-nents used on CDD systems which may be installed, purchasedor used in accordance with the requirements specified herein.1.4 The values stated in SI units are to be regarded as thestandard.1.5 This standard does not purport to address all of thesafety con
6、cerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2B117 Practice for Operating Salt Spray
7、 (Fog) ApparatusE 488 Test Methods for Strength of Anchors in Concreteand Masonry ElementsE 631 Terminology of Building ConstructionsE 894 Test Method for Anchorage of Permanent MetalRailing Systems and Rails for BuildingsE 1512 Test Methods for Testing Bond Performance ofBonded AnchorsE 2265 Termin
8、ology for Anchors and Fasteners in Concreteand Masonry2.2 ANSI Standards:ANSI Z359.1 Fall Arrest System Components3ANSI/AWS D, 14.4 Specification for Welded Joints inmachinery and Equipment32.3 ASCE Standard:ASCE 1-05 Minimum Design Loads for Buildings andOther Structures42.4 ASME Standard:ASME A120
9、 Safety Requirements for Powered Platformsfor Building Maintenance52.5 International Standards:CSA-Z259.10 Full Body Harness, M906CSA-Z259.2.3-99 Descent Control Devices6EN 292-1:1991 Basic Design Concepts and general Prin-ciples of Design for Safety Machinery7EN 362 Connectors and Attachment Hardwa
10、re7EN 1497 Rescue Equipment-Rescue Harness7EN 1498 Rescue Equipment Class B-Rescue Harness7EN 1891 Personal Protective Equipment7PrEN 341:2002 Personal Protective Equipment for Protec-tion Against Falls from Height72.6 ISO Standards:ISO 9002 Quality Management and Manufacturing QualityAssurance8ISO
11、10333-5 Connectors and Attachment Hardware81This specification is under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.77on High Rise Building External Evacuation Devices.Current edition approved Jan. 1, 2008. Published February
12、 2008. Originallyapproved in 2006. Last previous edition approved in 2006 as E2484 - 06.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summa
13、ry page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.4Available from American Society of Civil Engineers (ASCE), 1801 AlexanderBell Dr., Reston, VA 20191, http:/www.asce.org.5Available from American
14、Society of Mechanical Engineers (ASME), ASMEInternational Headquarters, Three Park Ave., New York, NY 10016-5990, http:/www.asme.org.6Available from Canadian Standards Association (CSA), 5060 Spectrum Way,Mississauga, ON L4W 5N6, Canada, http:/www.csa.ca.7Available from European Committee for Standa
15、rdization (CEN), 36 rue deStassart, B-1050, Brussels, Belgium, http:/www.cenorm.be.8Available from International Organization for Standardization (ISO), 1 rue deVaremb, Case postale 56, CH-1211, Geneva 20, Switzerland, http:/www.iso.ch.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C70
16、0, West Conshohocken, PA 19428-2959, United States.2.7 NEMA Standard:NEMA 250 Enclosures for Electrical Equipment92.8 NFPA Standard:NFPA 130 Appendix B 2.1.1 and B 2.1.2102.9 OSHA Document:OSHA Safety and Health Bulletin, SHIB 02-24-2004 Suspension Trauma/Orthostatic Intolerance112.10 UL Standard:UL
17、 1523 Controlled Descent Devices for Marine Use, 9, 15,16, 17 and 18123. Terminology3.1 See Terminology E 631 for definitions of general con-cepts related to building construction.3.2 Definitions of Terms Specific to This Standard:3.2.1 controlled descent device, (CDD) systema systemthat lowers one
18、or two people per descent, at a controlled rateof descent, with each person wearing a rescue harness, on theoutside of a building, from an upper level to the ground orother safe location.3.2.1.1 controlled descent device (CDD)a device that isan integral part of all CDD systems, which controls the ra
19、te ofdescent.3.2.1.2 automatic controlled descent devicea CDD thatprovides automatic control of the rate of descent without anyaction required of the user.3.2.1.3 automatic controlled descent device, with manualoverridea CDD that provides automatic control of the rate ofdescent with a manual overrid
20、e capability which gives the userthe ability to slow or stop the descent.3.2.2 force limitera mechanism that limits the force on theuser, rescue line, rail or track and all in line, load bearing CDDsystem components and parts to a specific value duringdeceleration.3.2.3 one time rescue CDDa CDD syst
21、em or CDD that iscapable of only one rescue descent.3.2.4 repetitive rescue CDDa CDD system or CDD that iscapable of being returned to the site of descent initiation andused repetitively.3.2.5 multiple rescue CDD systema CDD system capableof multiple rescues using multiple, one time rescue CDDs anda
22、 descent rail or track.3.2.6 rescue harnessan adjustable human body holdingdevice or harness assembly, which supports the pelvis and thetorso.3.2.6.1 separate rescue harnessa rescue harness is aseparate component of the CDD system that connects to arescue line or the CDD.3.2.6.2 integral rescue harn
23、essa rescue harness is anintegral part of a descending CDD system.3.2.7 rescue linea flexible cable or rope that is used tosupport individuals during descent.3.2.7.1 anchored rescue linea rescue line that is anchoredat the descent initiation location and is dispensed from orpasses through a descendi
24、ng CDD.3.2.7.2 descending rescue linea rescue line that is dis-pensed from or passes through a CDD that is anchored at thedescent initiation location.3.2.8 descent rail or trackload bearing assemblies onwhich CDDs are mounted, inserted or attached and secured.Descent rails and tracks are components
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME24842008STANDARDSPECIFICATIONFORMULTISTORYBUILDINGEXTERNALEVACUATIONCONTROLLEDDESCENTDEVICES 多层建筑

链接地址:http://www.mydoc123.com/p-531230.html