ASTM E1473-2016 Standard Test Methods for Chemical Analysis of Nickel Cobalt and High-Temperature Alloys《镍 钴和高温合金的化学分析的标准试验方法》.pdf
《ASTM E1473-2016 Standard Test Methods for Chemical Analysis of Nickel Cobalt and High-Temperature Alloys《镍 钴和高温合金的化学分析的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1473-2016 Standard Test Methods for Chemical Analysis of Nickel Cobalt and High-Temperature Alloys《镍 钴和高温合金的化学分析的标准试验方法》.pdf(57页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1473 09E1473 16Standard Test Methods forChemical Analysis of Nickel, Cobalt,Cobalt and High-Temperature Alloys1This standard is issued under the fixed designation E1473; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision,
2、 the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods describe the chemical analysis of nickel, cobalt,cobalt and high-temperature alloys ha
3、ving chemicalcompositions within the following limits:Element Concentration Range, %Aluminum 0.005 to 7.00Beryllium 0.001 to 0.05Boron 0.001 to 1.00Calcium 0.002 to 0.05Carbon 0.001 to 1.10Chromium 0.10 to 33.00Cobalt 0.10 to 75.00Copper 0.01 to 35.00Iron 0.01 to 50.00Lead 0.001 to 0.01Magnesium 0.0
4、01 to 0.05Manganese 0.01 to 3.0Molybdenum 0.01 to 30.0Niobium (Columbium) 0.01 to 6.0Nickel 0.10 to 98.0Nitrogen 0.001 to 0.20Phosphorus 0.002 to 0.08Sulfur 0.002 to 0.10Silicon 0.01 to 5.00Tantalum 0.005 to 1.00Tin 0.002 to 0.10Titanium 0.01 to 5.00Tungsten 0.01 to 18.00Vanadium 0.01 to 3.25Zinc 0.
5、001 to 0.01Zirconium 0.01 to 2.50Element Composition Range, %Aluminum 0.005 to 7.00Beryllium 0.001 to 0.05Boron 0.001 to 1.00Calcium 0.002 to 0.05Carbon 0.001 to 1.10Chromium 0.10 to 33.00Cobalt 0.10 to 75.00Copper 0.01 to 35.00Iron 0.01 to 50.00Lead 0.001 to 0.01Magnesium 0.001 to 0.05Manganese 0.0
6、1 to 3.0Molybdenum 0.01 to 30.0Niobium (Columbium) 0.01 to 6.0Nickel 0.10 to 98.0Nitrogen 0.001 to 0.20Phosphorus 0.002 to 0.08Sulfur 0.002 to 0.101 These test methods are under the jurisdiction ofASTM Committee E01 on Analytical Chemistry for Metals, Ores, and Related Materials and are the direct r
7、esponsibilityof Subcommittee E01.08 on Ni and Co and High Temperature Alloys.Current edition approved June 1, 2009April 1, 2016. Published July 2009May 2016. Originally approved in 1992. Last previous edition approved in 20032009 asE1473 03.E1473 09. DOI: 10.1520/E1473-09.10.1520/E1473-16.This docum
8、ent is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as a
9、ppropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1Silicon 0.01 to 5.00Tantalum 0.005 to 1.00Tin 0.002 to 0.1
10、0Titanium 0.01 to 5.00Tungsten 0.01 to 18.00Vanadium 0.01 to 3.25Zinc 0.001 to 0.01Zirconium 0.01 to 2.501.2 The test methods in this standard are contained in the sections indicated as follows:SectionsAluminum, Total by the 8-Quinolinol Gravimetric Method(0.20 % to 7.00 %)62 to 69Chromium by the At
11、omic Absorption Method(0.018 % to 1.00 %)100 to 109Chromium by the Peroxydisulfate OxidationTitration Method(0.10 % to 33.00 %)110 to 118Cobalt by the Ion-Exchange-Potentiometric Titration Method(2 % to 75 %)34 to 41Cobalt by the Nitroso-R-Salt Photometric Method(0.10 % to 5.0 %)42 to 51Copper by Ne
12、ocuproine Photometric Method(0.010 % to 10.00 %)52 to 61Iron by the Silver Reduction Titrimetric Method(1.0 % to 50.0 %)127 to 134Manganese by the Metaperiodate Photometric Method(0.05 % to2.00 %)8 to 17Molybdenum by the Ion Exchange8-HydroxyquinolineGravimetric Method (1.5 % to 30 %)119 to 126Molyb
13、denum by the Photometric Method(0.01 % to 1.50 %)88 to 99Nickel by the Dimethylglyoxime Gravimetric Method(0.1 % to 84.0 %)70 to 77Niobium by the Ion ExchangeCupferron Gravimetric Method(0.5 % to 6.0 %)135 to 142Silicon by the Gravimetric Method (0.05 % to 5.00 %) 27 to 33Sulfur by the Combustion-Io
14、date Titration Method(0.006 % to 0.1 %)218 to 26Tantalum by the Ion ExchangePyrogallol SpectrophotometricMethod (0.03 % to 1.0 %)143 to 151Tin by the Solvent Extraction-Atomic Absorption Method(0.002 % to 0.10 %)78 to 87Aluminum, Total by the 8-Quinolinol Gravimetric Method(0.20 % to 7.00 %)53 to 60
15、Chromium by the Atomic Absorption Method(0.018 % to 1.00 %)91 to 100Chromium by the Peroxydisulfate OxidationTitration Method(0.10 % to 33.00 %)101 to 109Cobalt by the Ion-Exchange-Potentiometric Titration Method(2 % to 75 %)25 to 32Cobalt by the Nitroso-R-Salt Spectrophotometric Method(0.10 % to 5.
16、0 %)33 to 42Copper by Neocuproine Spectrophotometric Method(0.010 % to 10.00 %)43 to 52Iron by the Silver Reduction Titrimetric Method(1.0 % to 50.0 %)118 to 125Manganese by the Metaperiodate Spectrophotometric Method(0.05 % to 2.00 %)8 to 17Molybdenum by the Ion Exchange8-HydroxyquinolineGravimetri
17、c Method (1.5 % to 30 %)110 to 117Molybdenum by the Spectrophotometric Method(0.01 % to 1.50 %)79 to 90Nickel by the Dimethylglyoxime Gravimetric Method(0.1 % to 84.0 %)61 to 68Niobium by the Ion ExchangeCupferron Gravimetric Method(0.5 % to 6.0 %)126 to 133Silicon by the Gravimetric Method (0.05 %
18、to 5.00 %) 18 to 24Tantalum by the Ion ExchangePyrogallol SpectrophotometricMethod (0.03 % to 1.0 %)134 to 142Tin by the Solvent Extraction-Atomic Absorption Method(0.002 % to 0.10 %)69 to 78These test methods were extracted from Test Methods E354 and the references to Test Methods E350, E351, E352,
19、 and E353 contained therein.E1473 1621.3 Methods for the determination of several elements not included in these test methods can be found in Other test methodsapplicable to the analysis of nickel alloys that may be used in lieu of or in addition to this method are Test Methods E30E1019,E76E1834, E1
20、835and, E1019E1917, E1938, E2465, E2594, E2823.1.4 Some of the concentrationcomposition ranges given in 1.1 are too broad to be covered by a single method, and therefore,these test methods contain multiple methods for some elements. The user must select the proper test method by matching theinformat
21、ion given in the scope and interference sections of each test method with the composition of the alloy to be analyzed.1.5 The values stated in SI units are to be regarded as standard. In some cases, exceptions allowed in Practice E380 are alsoused.1.6 This standard does not purport to address all of
22、 the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use. Specific hazard statements are given in Section 7 and in 13.4, 29.11
23、5.1.1, 15.1.2, 21.2, 22.5, 66.357.3,123.5114.5, 124.14115.4, 139.4130.4, 139.5130.5, 147.5138.5, and 147.6138.6.2. Referenced Documents2.1 ASTM Standards:2D1193 Specification for Reagent WaterE29 Practice for Using Significant Digits in Test Data to Determine Conformance with SpecificationsE30 Test
24、Methods for Chemical Analysis of Steel, Cast Iron, Open-Hearth Iron, and Wrought Iron (Withdrawn 1995)4E50 Practices forApparatus, Reagents, and Safety Considerations for ChemicalAnalysis of Metals, Ores, and Related MaterialsE60 Practice for Analysis of Metals, Ores, and Related Materials by Spectr
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME14732016STANDARDTESTMETHODSFORCHEMICALANALYSISOFNICKELCOBALTANDHIGHTEMPERATUREALLOYS 高温 合金 化学分析

链接地址:http://www.mydoc123.com/p-528751.html